All Practice Exams

100+ Free NSX 4.x Professional V2 Practice Questions

Pass your VMware NSX 4.x Professional V2 (2V0-41.24) - VCP-NV 2024 exam on the first try — instant access, no signup required.

✓ No registration✓ No credit card✓ No hidden fees✓ Start practicing immediately
100+ Questions
100% Free
1 / 100
Question 1
Score: 0/0

Which NSX component is responsible for the management plane and provides a single API entry point for all NSX configuration?

A
B
C
D
to track
2026 Statistics

Key Facts: NSX 4.x Professional V2 Exam

55

Questions

Broadcom 2V0-41.24 Guide

135 min

Exam Duration

Broadcom

300

Scaled Passing Score

Broadcom

$250

Exam Fee

Broadcom

GENEVE

NSX 4.x Encapsulation

NSX 4.x Docs

1700

Minimum TEP MTU

NSX 4.x Docs

2V0-41.24 has 55 questions in 135 minutes with a scaled passing score of 300 and a $250 USD fee. The current exam guide standardizes seven section headings (Architectures and Technologies; Products and Solutions; Planning and Designing; Installing/Configuring/Setup; Performance Tuning, Optimization, and Upgrades; Troubleshooting and Repairing; Administrative and Operational Tasks) but Broadcom does not publish official percentage weightings.

Sample NSX 4.x Professional V2 Practice Questions

Try these sample questions to test your NSX 4.x Professional V2 exam readiness. Each question includes a detailed explanation. Start the interactive quiz above for the full 100+ question experience with AI tutoring.

1Which NSX component is responsible for the management plane and provides a single API entry point for all NSX configuration?
A.NSX Edge node
B.NSX Manager
C.Transport node
D.Global Manager
Explanation: NSX Manager is the centralized management component that hosts the API server, policy plane, and management plane. It provides the single API entry point and UI for all NSX configuration and is deployed as a cluster of three nodes for high availability.
2How many NSX Manager nodes are recommended for a production NSX 4.x deployment to provide high availability?
A.1 node
B.2 nodes
C.3 nodes
D.5 nodes
Explanation: A production NSX Manager cluster requires three nodes behind a virtual IP or external load balancer. Three nodes provide quorum-based high availability for the policy, management, and control planes.
3Which encapsulation protocol does NSX use for overlay segments in NSX 4.x?
A.VXLAN
B.GENEVE
C.GRE
D.STT
Explanation: NSX 4.x uses GENEVE (Generic Network Virtualization Encapsulation) for overlay segments. GENEVE supports variable-length TLV metadata, which allows NSX to carry context such as security policy and service insertion data in the encapsulation header.
4What is the minimum MTU required end-to-end on the underlay physical network to support GENEVE-encapsulated overlay traffic in NSX 4.x?
A.1500
B.1600
C.1700
D.9000
Explanation: VMware recommends a minimum MTU of 1700 bytes on the physical underlay for NSX 4.x because GENEVE adds approximately 100 bytes of overhead to the original 1500-byte payload. Many designs use 9000 (jumbo) for headroom, but 1700 is the documented floor.
5Which two transport zone types are supported in NSX 4.x? (Choose the correct pair.)
A.Overlay and VXLAN
B.Overlay and VLAN
C.VLAN and GRE
D.Underlay and Overlay
Explanation: NSX 4.x supports two transport zone types: Overlay (for GENEVE-encapsulated tenant networks) and VLAN (for traditional VLAN-backed segments). A transport node may be associated with multiple transport zones of either type.
6Starting with NSX 4.x on ESXi 7.0 U3 and later, what is the supported host switch for new transport node deployments?
A.N-VDS
B.Standard vSwitch (vSS)
C.VDS 7.0 or later
D.Cisco Nexus 1000v
Explanation: In NSX 4.x, new ESXi transport nodes must use vSphere Distributed Switch (VDS) version 7.0 or later. N-VDS is deprecated for ESXi hosts; only Edge transport nodes still use N-VDS internally.
7Which NSX object is used to provide centralized services such as N-S routing, NAT, gateway firewall, and load balancing?
A.Distributed Router
B.Tier-0 Gateway
C.Logical Switch
D.Service Insertion Profile
Explanation: A Tier-0 Gateway provides north-south connectivity between the NSX overlay and the physical network. It hosts BGP/OSPF, ECMP, NAT, gateway firewall, and other centralized services on Edge nodes.
8Which NSX gateway is typically used to connect tenant or workload segments and provides E-W routing closest to the workloads?
A.Tier-0 Gateway
B.Tier-1 Gateway
C.Service Gateway
D.Edge Gateway
Explanation: Tier-1 Gateways are typically used per tenant or per application tier. They connect overlay segments and provide a distributed routing instance on every transport node so that east-west traffic between segments stays inside the host whenever possible.
9An administrator wants Tier-1 to advertise its connected segments to Tier-0 so they can be redistributed into BGP. Which T1 setting must be enabled?
A.Edge cluster only
B.Route advertisement for connected segments
C.Local egress
D.Service insertion
Explanation: On a Tier-1 gateway, route advertisement types control which prefixes the T1 announces to the upstream T0. To expose connected overlay segments, you enable advertisement of connected segments and ports; the T0 then redistributes them into BGP.
10Which dynamic routing protocols are supported on a Tier-0 Gateway in NSX 4.x?
A.BGP and OSPF
B.EIGRP and RIP
C.IS-IS only
D.Static routes only
Explanation: Tier-0 Gateways in NSX 4.x support BGP and OSPF for dynamic routing peering with the physical fabric, in addition to static routes. Tier-1 gateways do not run dynamic routing toward T0 — they exchange routes via internal route advertisement.

About the NSX 4.x Professional V2 Exam

The VMware NSX 4.x Professional V2 exam (2V0-41.24) leads to the VCP-NV 2024 credential. It validates the ability to install, configure, and manage NSX 4.x networking and security including Tier-0 and Tier-1 gateways, distributed firewall, IDS/IPS, NAT, VPN, load balancing, federation, and day-two operations.

Assessment

Multiple Choice, Drag and Drop, Point and Click, Hot-Area, Matching, and Multiple Selection Multiple Choice

Time Limit

135 minutes

Passing Score

300 (scaled)

Exam Fee

$250 USD (VMware by Broadcom / Pearson VUE)

NSX 4.x Professional V2 Exam Content Outline

Not publicly disclosed

Architectures and Technologies

NSX Manager, control/management plane, transport zones (overlay vs VLAN), N-VDS / VDS 7+ host switch, GENEVE encapsulation, MTU 1700+, and the DR/SR architecture of Tier-0 and Tier-1 gateways.

Not publicly disclosed

VMware Products and Solutions

Tier-0 and Tier-1 gateways, BGP/OSPF, ECMP, VRF Lite, distributed firewall (DFW), gateway firewall, security groups, L7 App ID, identity firewall, IDS/IPS, NSX Intelligence, NSX Advanced Threat Prevention, NAT, load balancing, IPsec/L2VPN, federation, and VPC.

Not publicly disclosed

Planning and Designing

Sizing NSX Manager and Edge form factors (VM vs bare metal), choosing T0 active-active vs active-standby, multi-tenant designs with Projects/VPC and VRF Lite, and Edge clustering for HA and ECMP.

Not publicly disclosed

Installing, Configuring, and Setup

Deploying NSX Manager clusters, registering Compute Managers, preparing transport nodes, building uplink profiles and IP pools, deploying Edges and creating Edge clusters, and configuring T0/T1, NAT, VPN, LB, and IDS/IPS.

Not publicly disclosed

Performance Tuning, Optimization, and Upgrades

Tuning Edge and DFW performance, sizing teaming policies and TEPs for full uplink utilization, managing NSX Manager retention, and running upgrades via the NSX Upgrade Coordinator (Edges → Hosts → Manager).

Not publicly disclosed

Troubleshooting and Repairing

Using Traceflow, Live Traffic Analysis, Port Mirror, and packet capture to triage overlay, BGP, DFW, and federation issues, and using support bundles for escalation to Broadcom.

Not publicly disclosed

Administrative and Operational Tasks

Backups to SFTP, certificate replacement, RBAC, integration with VMware Identity Manager / LDAP, log forwarding to external syslog, and day-two operational changes to gateways and policy.

How to Pass the NSX 4.x Professional V2 Exam

What You Need to Know

  • Passing score: 300 (scaled)
  • Assessment: Multiple Choice, Drag and Drop, Point and Click, Hot-Area, Matching, and Multiple Selection Multiple Choice
  • Time limit: 135 minutes
  • Exam fee: $250 USD

Keys to Passing

  • Complete 500+ practice questions
  • Score 80%+ consistently before scheduling
  • Focus on highest-weighted sections
  • Use our AI tutor for tough concepts

NSX 4.x Professional V2 Study Tips from Top Performers

1Lock in the DR/SR model — every gateway has a Distributed Router on every transport node and an optional Service Router on Edges.
2Memorize that NSX 4.x uses GENEVE encapsulation and requires at least MTU 1700 end-to-end on the underlay.
3Know which T0/T1 modes support stateful services: stateful = Active-Standby; stateless ECMP = Active-Active.
4Practice DFW with security groups, L7 App ID, and Identity Firewall — micro-segmentation is heavily represented.
5Understand the NSX 4.x upgrade order: Upgrade Coordinator runs Edges first, then hosts, then NSX Manager last.
6Use Traceflow for synthetic packet checks and Live Traffic Analysis for real flows; both are exam-favorite troubleshooting tools.
7Don't skip operations: SFTP backups, certificate replacement, RBAC, syslog forwarding, and support bundles are tested.

Frequently Asked Questions

What is the 2V0-41.24 exam and what does it certify?

2V0-41.24 is the VMware NSX 4.x Professional V2 exam. Passing it earns the VCP-NV 2024 credential, validating the ability to install, configure, and manage VMware NSX 4.x networking and security.

How many questions and how long is 2V0-41.24?

Broadcom's exam guide lists 55 questions in 135 minutes for 2V0-41.24, with a scaled passing score of 300 and a $250 USD fee.

Does Broadcom publish official domain percentages?

No. The exam guide groups objectives under seven standardized sections (Architectures and Technologies; Products and Solutions; Planning and Designing; Installing/Configuring/Setup; Performance Tuning/Optimization/Upgrades; Troubleshooting and Repairing; Administrative and Operational Tasks) but does not publish percentage weightings.

Is mandatory training still required to take 2V0-41.24?

No. Broadcom's May 6, 2024 certification policy update removed mandatory training and prerequisite certifications for VCP-level exams. Recommended NSX courses are still listed for preparation.

What's the difference between this exam and the older VCP-NV?

Older VCP-NV versions targeted NSX-T or NSX-V. 2V0-41.24 is the current path aligned to NSX 4.x, including GENEVE encapsulation, VDS 7+ host switching, NSX Federation, NSX Intelligence, and NSX Advanced Threat Prevention features.

How should I study for 2V0-41.24?

Build an NSX 4.x lab and practice transport-node prep, T0/T1 with BGP and ECMP, DFW with security groups and L7 App ID, IDS/IPS, NAT, VPN, LB, federation, and day-two operations such as backup, certificate, and upgrade workflows. Use timed 55-question simulations to match exam pacing.