Free Practice Questions for AZ ROC CR-67 Low Voltage Communication Systems
Exam-style questions and explanations by OpenExamPrep.
Loading practice questions...
Explore More Arizona Registrar of Contractors Trade Examinations
Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.
Key Facts: AZ ROC CR-67 Low Voltage Communication Systems Exam
80
Official Scored Questions
PSI Arizona ROC CR-67 Bulletin
120 Minutes
Time Limit
PSI Content Outline
70%
Passing Score
Arizona Registrar of Contractors
$66
Exam Fee
PSI Services LLC
Open-Book Computerized
Format
PSI Services LLC
2 Years
Trade Experience Requirement
Arizona Registrar of Contractors
Prepare for the official Arizona ROC CR-67 / C-67 Low Voltage Communication Systems contractor exam with 100 verified practice questions mapped directly to NEC, TIA/EIA, FOA, BICSI, and OSHA standards. The official PSI trade test consists of 60 questions over 180 minutes with a 70% passing threshold ($66 exam fee). This practice question bank delivers targeted questions covering code navigation, optical loss calculations, copper certification metrics, and pathway design.
Sample AZ ROC CR-67 Low Voltage Communication Systems Practice Questions
Try these sample questions to review concepts for the AZ ROC CR-67 Low Voltage Communication Systems exam. Each question includes a detailed explanation. Start the interactive quiz above for the full 100+ question experience with AI tutoring.
1According to NEC Article 725, what is the maximum power rating (in VA) allowed for a inherently limited Class 2 power source operating at AC voltages up to 30 volts?
2In communications cabling installations under NEC Article 800, which cable type is permitted as a direct substitute for Type CMR (Riser) communications cable?
3Which optical fiber cable type is designated by NEC Article 770 for installation in ducts, plenums, and other spaces used for environmental air, containing nonconductive materials only?
4According to NEC Article 760, which Power-Limited Fire Alarm (PLFA) cable rating is required for vertical runs in a shaft penetrating more than one floor?
5Under NEC 725.136, what is the minimum required separation distance between Class 2 or Class 3 conductors and ungrounded electric light, power, or Class 1 conductors when not separated by a permanent barrier?
6What does NEC Article 800 require regarding accessible abandoned communications cables during building renovation?
7Under NEC 770.133, nonconductive optical fiber cables (Type OFNP/OFNR) may occupy the same raceway or enclosure with electric light and power conductors ONLY if:
8Where must a listed primary protector be located for communications circuits entering a building according to NEC 800.90?
9Which wiring method requirement applies to Class 1 remote-control and signaling circuits governed by NEC 725.46?
10Under NEC 800.53, what is the minimum required clearance between open communications conductors and lightning protection system conductors?
About the AZ ROC CR-67 Low Voltage Communication Systems Exam
The Arizona ROC CR-67 (Dual Residential/Commercial) and C-67 (Commercial) Low Voltage Communication Systems examination is a computer-delivered, open-book trade licensing test administered by PSI Services LLC on behalf of the Arizona Registrar of Contractors. The 180-minute exam contains 80 scored multiple-choice questions covering all technical aspects of commercial and residential telecommunications, structured cabling, optical fiber systems, bonding/grounding, pathways, testing, and jobsite safety. Key topics include NEC Articles 725, 760, 770, and 800/805, TIA-568 copper and fiber standards, TIA-569 pathways and spaces, TIA-607 grounding, PoE load calculations, optical loss budget analysis, OTDR trace interpretation, and OSHA 1926 safety regulations. Candidates must achieve a minimum score of 70% to pass.
Exam sponsor: Arizona ROC / PSI Services LLC. The requirements and fees below concern the certification or admission exam, separate from our free practice resources.
Questions
60 questions
Time Limit
120 minutes
Passing Score
70%
Fees, eligibility, and exam policies can change. Confirm them with the exam sponsor before applying or paying.
Official sources
- NFPA 70: National Electrical Code (NEC) 2023/2026 (Articles 250, 300, 725, 760, 770, 800, 805)
- ANSI/TIA-568.0-D / 568.1-D / 568.2-D: Generic Telecommunications Cabling for Customer Premises & Balanced Twisted-Pair Cabling
- ANSI/TIA-568.3-D: Optical Fiber Cabling Components Standard
- ANSI/TIA-569-E: Telecommunications Pathways and Spaces
- ANSI/TIA-606-C: Administration Standard for Telecommunications Infrastructure
- ANSI/TIA-607-D: Generic Telecommunications Bonding and Grounding (Earthing) for Customer Premises
- FOA (Fiber Optic Association) Reference Guide to Fiber Optics
- BICSI Telecommunications Distribution Methods Manual (TDMM)
- OSHA 29 CFR 1926 Construction Industry Safety Standards
- PSI Candidate Information Bulletin - Arizona Registrar of Contractors CR-67 Low Voltage Communication Systems
Our practice resources: topics covered
We aim to reflect publicly available exam outlines and topic information in our study resources. Coverage, format, and difficulty may differ from the actual exam, and we cannot guarantee that every detail is accurate or current. Confirm exam requirements, fees, and policies with the official exam sponsor.
General Low Voltage Electrical Knowledge
15 of 60 items on the official PSI content outline. Ohm's law, power limits, Class 2 and 3 circuits, NEC Articles 725/760/770/800 basics and pathways.
Conductors
14 of 60 items on the official PSI content outline. Copper and fiber cable types, categories, ratings, terminations, supports and separation from power.
Fire and Security Detection and Alarms
12 of 60 items on the official PSI content outline. Initiating and notification devices, circuit classes, survivability and NFPA 72 practice.
Digital Communications Systems
10 of 60 items on the official PSI content outline. Structured cabling, networking, Power over Ethernet and telecommunications rooms.
Grounding and Bonding
7 of 60 items on the official PSI content outline. Telecommunications bonding backbone, busbars, primary protectors and surge protection.
PA Systems
2 of 60 items on the official PSI content outline. Public address and audio distribution wiring and speaker circuits.
Preparing for the AZ ROC CR-67 Low Voltage Communication Systems Exam
What You Need to Know
- Passing score: 70%
- Exam length: 60 questions
- Time limit: 120 minutes
- Exam / certification fees: $66 Official sources
Using Our Practice Resources
- Work through all 100 available questions
- Review every answer and explanation
- Track weak areas and revisit them
- Use our AI tutor for tough concepts
AZ ROC CR-67 Low Voltage Communication Systems: Suggested Study Strategy
Frequently Asked Questions
What work is authorized under the Arizona ROC CR-67 license?
The CR-67 license classification authorizes contractors to install, service, and maintain low voltage communication systems in residential and commercial structures. This includes telephone, data, structured cabling networks, fiber optics, sound systems, intercoms, public address, master antenna television (MATV/CATV), and power-limited signaling circuits.
How many questions are on the official AZ ROC CR-67 trade exam, and what is the passing score?
The official PSI CR-67 content outline lists 60 multiple-choice questions with 120 minutes allowed. A minimum passing score of 70% (at least 42 correct answers) is required.
Is the Arizona CR-67 Low Voltage exam open-book?
Yes. The examination is open-book. Candidates are permitted to bring approved reference materials—such as the National Electrical Code (NFPA 70), TIA cabling standards reference books, BICSI manuals, and OSHA 1926 rules—into the PSI testing center, provided they are bound and tabbed per PSI instructions.
What calculations appear on the CR-67 Low Voltage examination?
Calculations on the CR-67 exam include optical link attenuation loss budgets (dB = length x loss/km + splice loss + connector loss), conduit fill percentage (max 40% for 3+ cables), copper cable length/propagation delay, voltage drop for 24VAC/24VDC Class 2 circuits, and Power over Ethernet (PoE) bundle thermal rise limits.
What is the difference between C-67, R-67, and CR-67 licenses?
C-67 covers commercial low voltage communication systems, R-67 covers residential low voltage communication systems, and CR-67 is a dual license covering both commercial and residential systems. Passing the CR-67 trade exam fulfills the technical examination requirement for all three licenses.