Key Facts: OR Fire Sprinkler Exam

70%

Passing Score

State Fire Marshal

100 Q

Practice Questions

OpenExamPrep

NICET

Certification Required

NFSA

NFPA 13

Primary Standard

NFPA

Annual

License Renewal

State

Oregon requires fire sprinkler contractors to obtain state licensing. The exam covers NFPA sprinkler standards, system design, hydraulic calculations, and state-specific fire protection regulations.

Sample OR Fire Sprinkler Practice Questions

Try these sample questions to review concepts for the OR Fire Sprinkler exam. Each question includes a detailed explanation. Start the interactive quiz above for the full 100+ question experience with AI tutoring.

1Which Oregon agency oversees fire sprinkler contractor licensing?
A.Oregon State Fire Marshal
B.Oregon Construction Contractors Board (CCB)
C.Oregon Department of Consumer and Business Services
D.Oregon Bureau of Labor and Industries
Explanation: The Oregon Construction Contractors Board (CCB) licenses fire sprinkler contractors in Oregon. Contractors must hold a CCB license with the appropriate specialty endorsement to perform fire sprinkler work.
2What type of CCB endorsement is required for fire sprinkler contractors in Oregon?
A.Residential General Contractor
B.Commercial Specialty Contractor
C.Residential Limited Contractor
D.Home Services Contractor
Explanation: Fire sprinkler contractors in Oregon typically need a Commercial Specialty Contractor endorsement from the CCB. This endorsement covers specialty trades including fire protection system installation.
3What training must an Oregon CCB licensee's Responsible Managing Individual (RMI) complete?
A.No training is required
B.16 hours of law and business training and pass an open-book exam
C.40 hours of fire sprinkler installation training
D.A 4-year college degree
Explanation: Oregon requires the Responsible Managing Individual (RMI) for a CCB-licensed contractor to complete 16 hours of law and business training and pass an open-book examination before obtaining a contractor license.
4What is the surety bond requirement for a Commercial Specialty Contractor Level 1 in Oregon?
A.$15,000
B.$25,000
C.$55,000
D.$80,000
Explanation: Oregon CCB requires a Commercial Specialty Contractor Level 1 to maintain a $55,000 surety bond. This bond protects consumers from financial loss due to contractor negligence or breach of contract.
5What fire code does Oregon currently enforce for fire sprinkler requirements?
A.The 2015 Oregon Fire Code
B.The 2022 Oregon Fire Code (transitioning to 2025 OFC)
C.The International Building Code only
D.No statewide fire code exists
Explanation: Oregon enforces the 2022 Oregon Fire Code based on the International Fire Code with state amendments. The 2025 Oregon Fire Code has an effective date of October 1, 2025, with a 180-day phase-in period.
6In Portland, Oregon, what is required to perform automatic sprinkler system work?
A.Only a CCB license
B.A Certificate of Fitness issued by Portland Fire and Rescue in addition to a CCB license
C.A federal contractor permit
D.No additional requirements beyond the CCB license
Explanation: Portland Fire and Rescue requires a Certificate of Fitness for individuals performing automatic sprinkler system installation, alteration, testing, service, or repair. This is in addition to the CCB license requirement.
7How many questions are on the Portland Fire and Rescue Certificate of Fitness exam for automatic sprinkler systems?
A.25 questions
B.35 questions
C.45 questions
D.100 questions
Explanation: The Portland Fire and Rescue Certificate of Fitness exam for automatic sprinkler system installation, alteration, testing, service, or repair consists of 45 questions. The passing score is 75%.
8What NFPA standards are tested on the Portland Certificate of Fitness for sprinkler systems?
A.NFPA 72 only
B.NFPA 13 and NFPA 25
C.NFPA 10 and NFPA 17
D.NFPA 101 only
Explanation: The Portland Certificate of Fitness exam for automatic sprinkler systems is based on NFPA 13 (Installation of Sprinkler Systems) and NFPA 25 (Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems).
9Is the Portland Certificate of Fitness exam open-book or closed-book?
A.Closed-book with no references allowed
B.Open-book with all materials provided during the test
C.Open-book but candidates must bring their own materials
D.Take-home exam
Explanation: The Portland Certificate of Fitness exam is open-book. All reference materials are provided during the test. No outside materials or electronic devices are allowed.
10What is the annual fee for a Portland Certificate of Fitness?
A.$25
B.$45
C.$75
D.$100
Explanation: Each Portland Certificate of Fitness type costs $45 for the first year. Annual renewal is $30 per certification type. There is no fee for taking the test unless you pass.

About the OR Fire Sprinkler Exam

The Oregon fire sprinkler contractor exam covers NFPA 13/13D/13R sprinkler system design and installation, NFPA 25 inspection and testing, state licensing requirements, NICET certification, hydraulic calculations, and state fire code compliance.

Exam sponsor: Oregon State Fire Marshal. The requirements and fees below concern the certification or admission exam, separate from our free practice resources.

Questions

100 questions

Time Limit

2 hours

Passing Score

70%

Exam / Certification Fees

Varies

Exam sponsor website

Reported exam pass rate: 70%. estimated first-time pass rate This describes exam candidates, not OpenExamPrep users or results from using our resources. Exam sponsor website

Fees, eligibility, and exam policies can change. Confirm them with the exam sponsor before applying or paying.

Our practice resources: topics covered

We aim to reflect publicly available exam outlines and topic information in our study resources. Coverage, format, and difficulty may differ from the actual exam, and we cannot guarantee that every detail is accurate or current. Confirm exam requirements, fees, and policies with the official exam sponsor.

25%

System Design

NFPA 13/13D/13R, sprinkler types, spacing, coverage, pipe sizing

20%

Installation

Pipe hanging, bracing, connections, testing, commissioning

20%

Inspection & Testing

NFPA 25, ITM requirements, acceptance testing, impairments

20%

Regulations

State licensing, NICET, fire code, permits, insurance

15%

Hydraulics

Hydraulic calculations, water supply, backflow prevention, pressure

Preparing for the OR Fire Sprinkler Exam

What You Need to Know

  • Passing score: 70%
  • Exam length: 100 questions
  • Time limit: 2 hours
  • Exam / certification fees: Varies Official sources

Using Our Practice Resources

  • Work through all 100 available questions
  • Review every answer and explanation
  • Track weak areas and revisit them
  • Use our AI tutor for tough concepts

OR Fire Sprinkler: Suggested Study Strategy

1Master NFPA 13 sprinkler system design and installation requirements
2Study hydraulic calculation methods and water supply analysis
3Know NFPA 25 inspection, testing, and maintenance schedules
4Understand Oregon's fire sprinkler contractor licensing requirements
5Review sprinkler head types, temperature ratings, and spacing rules

Frequently Asked Questions

What does the fire sprinkler contractor exam cover?

The exam covers NFPA 13/13D/13R sprinkler design, NFPA 25 inspection, hydraulic calculations, state licensing requirements, and fire code compliance.

What NICET level is required?

Most states require NICET Level II or III certification in water-based systems layout for fire sprinkler contractor licensing.

What is the passing score?

A minimum score of 70% is typically required to pass the fire sprinkler contractor licensing exam.

What NFPA standards are tested?

The exam primarily covers NFPA 13 (sprinkler installation), NFPA 13D (one/two-family dwellings), NFPA 13R (residential), and NFPA 25 (inspection/testing/maintenance).