Question 1
Score: 0/0

What temperature rating should sprinklers have in areas near commercial cooking equipment per NFPA 13?

A
B
C
D
to track
2026 Statistics

Key Facts: OH Fire Sprinkler Exam

70%

Passing Score

State Fire Marshal

100 Q

Practice Questions

OpenExamPrep

NICET

Certification Required

NFSA

NFPA 13

Primary Standard

NFPA

Annual

License Renewal

State

Ohio requires fire sprinkler contractors to obtain state licensing. The exam covers NFPA sprinkler standards, system design, hydraulic calculations, and state-specific fire protection regulations.

Sample OH Fire Sprinkler Practice Questions

Try these sample questions to test your OH Fire Sprinkler exam readiness. Each question includes a detailed explanation. Start the interactive quiz above for the full 100+ question experience with AI tutoring.

1Which Ohio state agency administers fire protection certification for sprinkler contractors?
A.Ohio Department of Commerce, Division of State Fire Marshal
B.Ohio Department of Health
C.Ohio Bureau of Workers' Compensation
D.Ohio Construction Industry Licensing Board
Explanation: The Ohio Division of State Fire Marshal under the Ohio Department of Commerce administers fire protection certification, including licensing for automatic sprinkler and standpipe system contractors.
2What is the Ohio fire protection certification category for automatic sprinkler and standpipe systems?
A.Category 4 — Fire Alarm and Detection
B.Category 1 — Automatic Sprinklers and Standpipe Systems
C.Category 3 — Fire Pumps
D.Category 10 — Diesel Fire Pump Technician
Explanation: Category 1 under Ohio's fire protection certification covers Automatic Sprinklers and Standpipe Systems. The exam references NFPA 13, NFPA 14, NFPA 13R, NFPA 13D, and NFPA 25.
3Which NFPA standards are referenced for the Ohio Category 1 sprinkler certification exam?
A.NFPA 10, NFPA 17, and NFPA 2001
B.NFPA 13 (2022), NFPA 14 (2019), NFPA 13R (2022), NFPA 13D (2022), and NFPA 25 (2023)
C.NFPA 72 (2022) and NFPA 70 (2023)
D.NFPA 20 (2022) and NFPA 24 (2022) only
Explanation: The Ohio Category 1 exam references NFPA 13 (2022 edition), NFPA 14 (2019 edition), NFPA 13R (2022 edition), NFPA 13D (2022 edition), and NFPA 25 (2023 edition) for automatic sprinkler and standpipe systems.
4What is the format of the Ohio fire protection certification exam for sprinkler contractors?
A.Open-book, 3-hour exam
B.Closed-book, 2-hour exam administered by PSI Services
C.Online, untimed exam
D.Practical hands-on exam at a job site
Explanation: Ohio fire protection certification exams are closed-book and candidates have two hours to complete the exam. Exams are administered by PSI Services. Candidates must supply their own reference material for study beforehand.
5Under Ohio Administrative Code 1301:7-7-09, what must happen when a sprinkler system is found impaired or out of service?
A.The building owner may continue normal operations
B.An impairment tag must be placed per NFPA 25 and the fire department must be notified
C.Only a written report to the insurance company is required
D.The building must be demolished within 30 days
Explanation: Ohio Fire Code Section 901.6.3.1 requires an impairment tag in accordance with NFPA 25 when a sprinkler system is found impaired. Section 901.7 requires immediate notification of the fire department and fire code official.
6What edition of the Ohio Fire Code are sprinkler certification exams currently based on?
A.2019 edition
B.2022 edition
C.2025 edition
D.2015 edition
Explanation: Ohio fire protection certification exams are prepared from the Ohio Administrative Code section 1301:7-7-09 (Ohio Fire Code), 2025 edition, along with Ohio Building Code Chapter 9, 2024 edition, and referenced NFPA standards.
7In Ohio, who is required to hold a fire protection certification?
A.Only company owners
B.All companies and individuals involved in servicing, testing, repairing, or installing fire protection equipment for profit
C.Only government employees
D.Only engineers who design systems
Explanation: Ohio requires all companies and individuals involved in the business of servicing, testing, repairing, maintenance, or installation of fire protection equipment for profit to hold fire protection certification from the State Fire Marshal.
8Under Ohio Fire Code, what standard must sprinkler systems be designed and installed in accordance with?
A.NFPA 72
B.NFPA 13 as listed in rule 1301:7-7-80
C.NFPA 10
D.NFPA 101
Explanation: Ohio Fire Code Section 903.3.1.1 requires automatic sprinkler systems to be designed and installed in accordance with NFPA 13 as listed in rule 1301:7-7-80 of the Administrative Code.
9What is the maximum number of sprinklers allowed in a limited area sprinkler system under Ohio Fire Code?
A.6 sprinklers
B.12 sprinklers
C.19 sprinklers
D.25 sprinklers
Explanation: Ohio Fire Code Section 903.3.8.1 states that limited area sprinkler systems shall not exceed 19 sprinklers in any single fire area, consistent with the International Fire Code provision.
10Under Ohio Fire Code, what occupancy classifications may be protected by limited area sprinkler systems?
A.Any occupancy classification
B.Only Light Hazard and Ordinary Hazard Group 1 as classified by NFPA 13
C.Only Extra Hazard occupancies
D.Only residential occupancies
Explanation: Ohio Fire Code Section 903.3.8.2 restricts limited area sprinkler systems to areas classified by NFPA 13 as Light Hazard or Ordinary Hazard Group 1 only.

About the OH Fire Sprinkler Exam

The Ohio fire sprinkler contractor exam covers NFPA 13/13D/13R sprinkler system design and installation, NFPA 25 inspection and testing, state licensing requirements, NICET certification, hydraulic calculations, and state fire code compliance.

Questions

100 scored questions

Time Limit

2 hours

Passing Score

70%

Exam Fee

Varies (Ohio State Fire Marshal)

OH Fire Sprinkler Exam Content Outline

25%

System Design

NFPA 13/13D/13R, sprinkler types, spacing, coverage, pipe sizing

20%

Installation

Pipe hanging, bracing, connections, testing, commissioning

20%

Inspection & Testing

NFPA 25, ITM requirements, acceptance testing, impairments

20%

Regulations

State licensing, NICET, fire code, permits, insurance

15%

Hydraulics

Hydraulic calculations, water supply, backflow prevention, pressure

How to Pass the OH Fire Sprinkler Exam

What You Need to Know

  • Passing score: 70%
  • Exam length: 100 questions
  • Time limit: 2 hours
  • Exam fee: Varies

Keys to Passing

  • Complete 500+ practice questions
  • Score 80%+ consistently before scheduling
  • Focus on highest-weighted sections
  • Use our AI tutor for tough concepts

OH Fire Sprinkler Study Tips from Top Performers

1Master NFPA 13 sprinkler system design and installation requirements
2Study hydraulic calculation methods and water supply analysis
3Know NFPA 25 inspection, testing, and maintenance schedules
4Understand Ohio's fire sprinkler contractor licensing requirements
5Review sprinkler head types, temperature ratings, and spacing rules

Frequently Asked Questions

What does the fire sprinkler contractor exam cover?

The exam covers NFPA 13/13D/13R sprinkler design, NFPA 25 inspection, hydraulic calculations, state licensing requirements, and fire code compliance.

What NICET level is required?

Most states require NICET Level II or III certification in water-based systems layout for fire sprinkler contractor licensing.

What is the passing score?

A minimum score of 70% is typically required to pass the fire sprinkler contractor licensing exam.

What NFPA standards are tested?

The exam primarily covers NFPA 13 (sprinkler installation), NFPA 13D (one/two-family dwellings), NFPA 13R (residential), and NFPA 25 (inspection/testing/maintenance).