Key Facts: CONOCER Instalador Fotovoltaico Exam

4 Elements

Verify, Install, Connect, Start Up

EC0586.01 standard

Up to 1,000 V

Grid-Tied, No Batteries

EC0586.01 standard

±15% STC

Module and String Voc Check

EC0586.01 standard

2 h + 6 h

Estimated Desk and Field Time

EC0586.01 standard

14/12/2017

DOF Publication Date

EC0586.01 standard

< 0.7 MW

Distributed Generation Limit

Ley del Sector Eléctrico (2025)

CONOCER EC0586.01 (Instalación de sistemas fotovoltaicos en residencia, comercio e industria) is Mexico's competency standard for grid-tied solar PV installers. Accredited certifiers evaluate four elements, site verification, mounting, electrical connection, and startup, in a real or simulated installation and issue a judgment of Competente or Todavía no competente. This independent OpenExamPrep bank offers English-language practice MCQs on the EC0586.01 criteria and NOM-001-SEDE-2012 Article 690.

Sample CONOCER Instalador Fotovoltaico Practice Questions

Try these sample questions to review concepts for the CONOCER Instalador Fotovoltaico exam. Each question includes a detailed explanation. Start the interactive quiz above for the full 79+ question experience with AI tutoring.

1Which systems does CONOCER EC0586.01 cover?
A.Off-grid systems with battery banks, charge controllers, and backup generators at remote sites
B.Solar water heaters and pool heaters for dwellings, small businesses, and hotels
C.Utility-scale plants connected to the grid at medium or high voltage through substations
D.Grid-tied PV systems (SFVI) without batteries in homes, businesses, and industry, up to 1,000 V
Explanation: EC0586.01 describes the installer of sistemas fotovoltaicos interconectados (SFVI) in residences, commerce, and industry, at low voltage (up to 1,000 V) and without battery backup. Solar water heating is certified under separate standards such as EC0325 and EC0473.
2In EC0586.01, the installer works from the Carpeta del Proyecto (CP). Which set of documents does the standard's glossary list for the CP?
A.Only the latest utility bill, the client's official identification, and a copy of the property deed
B.The utility's transformer study, the municipal building permit, and the structural engineer's report
C.Plans, one-line and connection diagrams, record form, material and tool lists, assembly sheets, manuals
D.The installer's certificate, liability insurance policy, and photos of the roof from each side
Explanation: The EC0586.01 glossary defines the CP as a physical folder with the Plano de Planta, Plano Eléctrico, Diagrama Unifilar, Diagramas de Conexiones, Formato de Registro, Lista de Materiales y Equipo, Lista de Herramientas, Hojas de Contenido y Armado, and installation manuals of the main equipment. Most performance criteria are checked against these documents.
3When corroborating the site's feasibility under EC0586.01 Element 1, which action is part of the performance criteria?
A.Redesigning the array layout on site to use more of the roof area and add the modules the client wants
B.Measuring the building's structural capacity with load tests before any of the equipment is carried up
C.Negotiating the interconnection contract and the meter change with the utility on the client's behalf
D.Checking the site against the Plano de Planta for shading obstacles, and marking risk points and a safe route
Explanation: Element 1 asks the installer to physically check that the assigned place meets the Plano de Planta conditions without shading obstacles or risks, measure the raceway distance, check materials against the list, confirm the fastening elements suit the surfaces, and identify, label, and delimit the high-risk points and the safe route for materials.
4EC0586.01 requires the installer to corroborate the building's general grounding system before installing. Besides confirming that it exists as shown in the CP, what else must be checked?
A.That the connection point is not part of a down conductor of the lightning protection system
B.That the grounding electrode is painted or coated to protect it against corrosion in the soil
C.That the neutral is disconnected from ground at the service equipment to avoid stray currents
D.That the ground rod is at least 30 cm long and driven vertically into moist soil
Explanation: Element 1 requires physically corroborating the grounding system shown in the CP and corroborating that the grounding connection point is not part of any down conductor (conductor de bajada) of the external lightning protection system. The glossary defines the down conductor with reference to NMX-J-549.
5At the load center where the SFVI will connect, what does EC0586.01 ask the installer to corroborate?
A.That the load center has a spare slot for the PV breaker, regardless of its existing protections
B.That the load center is replaced with a new, larger one in every case before the SFVI is connected
C.That its protections match the one-line and connection diagrams, reporting their condition
D.That all branch breakers are rated above 50 A so they can accept the inverter's backfeed
Explanation: Element 1 requires physically locating the AC connection points and raceway routes, corroborating that the load center's elements match the overcurrent protection capacities in the Diagrama Unifilar and Diagrama de Conexiones, visually reviewing their condition, and notifying the supervisor of what was found.
6Before installing, EC0586.01 asks the installer to corroborate the grid voltage at the load center with a multimeter or voltmeter. Which set of measurements does the standard describe?
A.Only the voltage between one phase and the metal enclosure of the load center, at no load
B.Phase-to-phase and phase-to-neutral voltages, plus the voltage between neutral and ground
C.Only the open-circuit voltage of one module in sunlight, to compare it with the grid voltage
D.The insulation resistance of the service entrance conductors, measured with a megohmmeter
Explanation: Element 1 requires checking visually that the load center has phase, grounded (neutral), and grounding conductors, and measuring the voltage between phases, from phases to neutral, and the potential difference between the grounded and grounding conductors at the terminals indicated in the connection diagram.
7When preparing tools under EC0586.01, what must the installer verify about the measuring equipment?
A.No low-battery indication, and probes and leads with their insulation intact
B.That it was bought within the last year and still has its original packaging
C.That it is the same brand as the inverter so the readings agree with its display
D.Only that it turns on and shows a reading when the probes are touched together
Explanation: Element 1 asks the installer to record the tools in the CP's tool list, check that hand tools are free of wear, damage, and deformation, check that electromechanical tools work according to their manuals, and verify that measuring equipment does not show low battery and that its probes and conductors keep their insulation.
8While checking materials against the Lista de Materiales y Equipo, the installer finds an inverter with a dented enclosure that could affect its function. What does EC0586.01 require?
A.Install it and note the damage later
B.Return it to the supplier without telling anyone
C.Straighten the enclosure with a hammer
D.Notify the supervisor about the damaged component
Explanation: Element 1 requires verifying that mechanical and electrical components match the list and are free of blows and deformations that affect their function, notifying the supervisor if any component is damaged, and handing the verified list to the supervisor.
9EC0586.01 lists an emergent situation in Element 1: the DC voltage to be handled is 1,000 V or more. What is the expected response?
A.Continue installing, since the inverter will limit the DC voltage once it starts up
B.Short-circuit the modules temporarily to lower the voltage while the wiring is done
C.Suspend work, verify with the supervisor, and request the corresponding PPE and tools
D.Split the array into two halves on site and keep working without telling the supervisor
Explanation: Because the standard covers low-voltage systems up to 1,000 V, a DC voltage equal to or above 1,000 V is an emergent situation. The expected response is to suspend the installation, verify with the supervisor, and request the appropriate PPE and tools.
10EC0586.01's attitude of responsibility in Element 1 is shown by verifying, before installing, that certain items are available in addition to PPE. Which set does it name?
A.A first-aid kit, a Type C fire extinguisher, drinking water, and UV protection
B.A portable generator, an extension ladder, and a two-way radio for the crew
C.A water hose, a Type A fire extinguisher, and dark sunglasses for every crew member
D.Spare modules, a spare inverter, and extra connectors in case of damage
Explanation: The attitude item lists a first-aid kit, at least one fire extinguisher for Type C (electrical) fires, means of hydration, and protection against UV rays, in addition to the installer's PPE. The evaluation requirements also call for a first-aid kit, a Type C extinguisher, and a contingency plan.

About the CONOCER Instalador Fotovoltaico Exam

Independent CONOCER EC0586.01 practice questions by OpenExamPrep. EC0586.01 (Instalación de sistemas fotovoltaicos en residencia, comercio e industria) is the CONOCER competency standard for installers of grid-interconnected photovoltaic systems up to 1,000 V without batteries. The standard is published in Spanish, and certification follows a competency evaluation of performances, products, knowledge, and attitudes by an accredited certifier, not an official multiple-choice test. This bank is an English-language MCQ study adaptation covering site verification, mounting, DC and AC connection, NOM-001-SEDE-2012 Article 690 rules, and startup with anti-islanding checks; it is not an official translation and does not replace the evaluation.

Exam sponsor: CONOCER (Consejo Nacional de Normalización y Certificación de Competencias Laborales). The requirements and fees below concern the certification or admission exam, separate from our free practice resources.

Assessment

One standard with four elements, published in the DOF on 14 December 2017 and developed by the committees of Comercio, Industria y Servicios de Baja California, Energía Renovable y Eficiencia Energética, and INFONAVIT: Elemento 1 (Verificar las condiciones para la instalación del SFVI), Elemento 2 (Instalar los componentes mecánicos y eléctricos del SFVI), Elemento 3 (Conectar los componentes eléctricos del SFVI), and Elemento 4 (Realizar la puesta en marcha del SFVI). It covers grid-interconnected systems at low voltage (up to 1,000 V) without battery backup. Products include the verified materials list and tool list, the installed array, the Formato de Registro with Voc, Isc, and startup measurements, and the operating, labeled system.

Time Limit

About 8 or more hours estimated (2 hours desk work, at least 6 hours field)

Passing Score

Competency judgment: Competente or Todavía no competente

Exam / Certification Fees

Varies by accredited certifier (not published by CONOCER)

Exam sponsor website

Fees, eligibility, and exam policies can change. Confirm them with the exam sponsor before applying or paying.

Official sources

  • CONOCER — Registro Nacional de Estándares de Competencia (RENEC) · Source checked 2026-09-30RENEC lists EC0586.01 'Instalación de sistemas fotovoltaicos en residencia, comercio e industria' as a current standard with accredited certifiers
  • CONOCER — RENEC standard lookup (EC0586.01 ficha) · Source checked 2026-09-30Full EC0586.01 text: approved 30 November 2017 and published in the DOF on 14 December 2017, updating EC0586 (DOF 11 June 2015); four elements (E2936 to E2939); Nivel 2; revision period 2 years; evaluation estimated at 2 hours desk and at least 6 hours field
  • SENER — NOM-001-SEDE-2012 full text (PDF) · Source checked 2026-09-30Articles 690 and 705 (maximum voltage, circuit sizing, disconnects, arc-fault protection, labeling, anti-islanding, and point of connection) used in this bank; the Secretaría de Economía catalog lists the NOM as vigente
  • Cámara de Diputados — Ley del Sector Eléctrico · Source checked 2026-09-30Article 25 defines generación distribuida as plants of less than 0.7 MW by exempt generators, replacing the 0.5 MW threshold of the former Ley de la Industria Eléctrica
  • Comisión Nacional de Energía — Generación Distribuida · Source checked 2026-09-30Lists the current distributed-generation instruments, including the Manual de Interconexión de Centrales de Generación con Capacidad menor a 0.5 MW referenced by EC0586.01
  • CONOCER — Preguntas Frecuentes · Source checked 2026-09-30Costs vary by standard and evaluation center; certificate validity is set in each standard; the result is competent or not yet competent; certificates are issued by the Secretaría de Educación Pública

Our practice resources: topics covered

We aim to reflect publicly available exam outlines and topic information in our study resources. Coverage, format, and difficulty may differ from the actual exam, and we cannot guarantee that every detail is accurate or current. Confirm exam requirements, fees, and policies with the official exam sponsor.

Not published

Elemento 1: Verificar las condiciones para la instalación del SFVI

Corroborating the site against the Carpeta del Proyecto, marking work-at-height and electrical risk points, checking the grounding system and load-center protections, measuring grid voltages, verifying materials and tools, and knowing orientation methods such as the círculo indio.

Not published

Elemento 2: Instalar los componentes mecánicos y eléctricos del SFVI

Assembling, leveling, orienting, and anchoring the structure, checking torque with a torque wrench, preventing galvanic corrosion, mounting modules within their manual's requirements, and fixing inverters and junction boxes while keeping enclosure protection ratings.

Not published

Elemento 3: Conectar los componentes eléctricos del SFVI

Wiring DC and AC circuits, bonding to the existing grounding system, installing and opening protections and disconnects, checking module and string Voc and Isc against the ±15% STC criterion, and applying NOM-001-SEDE-2012 Article 690 sizing rules.

Not published

Elemento 4: Realizar la puesta en marcha del SFVI

Energizing in the manufacturer's sequence, recording synchronization time and measurements, labeling the system, verifying anti-islanding by opening the inverter's AC disconnect, and handing over to the supervisor.

Preparing for the CONOCER Instalador Fotovoltaico Exam

What You Need to Know

  • Passing score: Competency judgment: Competente or Todavía no competente
  • Assessment: One standard with four elements, published in the DOF on 14 December 2017 and developed by the committees of Comercio, Industria y Servicios de Baja California, Energía Renovable y Eficiencia Energética, and INFONAVIT: Elemento 1 (Verificar las condiciones para la instalación del SFVI), Elemento 2 (Instalar los componentes mecánicos y eléctricos del SFVI), Elemento 3 (Conectar los componentes eléctricos del SFVI), and Elemento 4 (Realizar la puesta en marcha del SFVI). It covers grid-interconnected systems at low voltage (up to 1,000 V) without battery backup. Products include the verified materials list and tool list, the installed array, the Formato de Registro with Voc, Isc, and startup measurements, and the operating, labeled system.
  • Time limit: About 8 or more hours estimated (2 hours desk work, at least 6 hours field)
  • Exam / certification fees: Varies by accredited certifier (not published by CONOCER) Official sources

Using Our Practice Resources

  • Work through all 79 available questions
  • Review every answer and explanation
  • Track weak areas and revisit them
  • Use our AI tutor for tough concepts

CONOCER Instalador Fotovoltaico: Suggested Study Strategy

1Know the Carpeta del Proyecto documents, because most EC0586.01 criteria are checked against the Plano de Planta, Plano Eléctrico, Diagrama Unifilar, Diagramas de Conexiones, and Hojas de Contenido y Armado.
2Memorize the electrical checks: each module's Voc within ±15% of STC, Isc not zero, and string Voc within ±15% STC and below the inverter's maximum input voltage.
3Learn the emergent situations and their responses: DC voltage of 1,000 V or more, a drilled hidden pipe, heat stroke, an inverter error code, and synchronization in under 1 minute.
4Practice NOM-001-SEDE-2012 Article 690 calculations: cold-temperature Voc correction, the 600 V dwelling limit, the 156% factor from 690-8, and the 120% bus rule in 705-12(d)(2).
5Remember the anti-islanding check: open the inverter's AC disconnect and verify no voltage at the output and no current in any output conductor.

Frequently Asked Questions

What is the official format of the CONOCER EC0586.01 evaluation?

An accredited certifier, evaluation center, or independent evaluator observes the candidate in a real or simulated installation that includes a microinverter system of at least 750 Wp and a central-inverter system of at least 1,500 Wp. The standard estimates 2 hours of desk work and at least 6 hours in the field. There is no official multiple-choice exam.

Does EC0586.01 cover battery or off-grid systems?

No. EC0586.01 covers grid-interconnected photovoltaic systems (SFVI) in homes, businesses, and industry at low voltage up to 1,000 V, without battery backup. Supervision of PV installations is covered by a separate standard, EC1181.

How is the CONOCER EC0586.01 certification graded?

The result is a competency judgment: Competente or Todavía no competente. A candidate found competent receives a certificate of labor competency issued by the Secretaría de Educación Pública through CONOCER.

How much does CONOCER EC0586.01 certification cost?

CONOCER does not publish a single national fee. It states that evaluation and certification costs vary by standard and by the evaluation center chosen, so candidates should ask accredited certifiers listed in RENEC for EC0586.01.

Is this OpenExamPrep question bank an official CONOCER test?

No. It is an independent, English-language multiple-choice study adaptation of the EC0586.01 criteria and the NOM-001-SEDE-2012 rules they rely on. It is not an official CONOCER examination or translation, and it cannot replace the practical evaluation.