Free Practice Questions for Habilitation Haute Tension
Exam-style questions and explanations by OpenExamPrep.
Loading practice questions...
Explore More French Electrical Safety Authorizations (NF C 18-510)
Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.
Key Facts: Habilitation Haute Tension Exam
NF C 18-510
National French standard governing electrical work safety
AFNOR / UTE
1 kV to 50 kV
HTA voltage band (alternating current)
NF C 18-510 § 3.1.2
> 50 kV
HTB voltage threshold (alternating current)
NF C 18-510 § 3.1.2
0.60 m
Minimum Approach Distance (DMA) for all HTA installations
NF C 18-510 Tableau 5
5 steps
Mandatory sequential steps of high-voltage consignation
NF C 18-510 § 7.1
3 years
Recommended refresher (recyclage) periodicity
INRS Brochure ED 6127
French high-voltage electrical habilitation is employer-issued and role-specific: H0/H0V for non-electrical operations, H1/H1V for execution, H2/H2V for leadership, and HC for consignation. INRS ED 6127 calls for a QCM of at least 15 questions with 70% required plus practical acceptance with no major error and at most two minor errors. There is no national duration or fee. This is a 92-item English-language MCQ study adaptation across the named roles.
Sample Habilitation Haute Tension Practice Questions
Try these sample questions to review concepts for the Habilitation Haute Tension exam. Each question includes a detailed explanation. Start the interactive quiz above for the full 92+ question experience with AI tutoring.
1Under French electrical safety standard NF C 18-510, what are the exact voltage boundaries defining the HTA (Haute Tension A) domain for alternating current (AC)?
2According to standard NF C 18-510, which voltage threshold marks the lower limit of the HTB (Haute Tension B) domain in alternating current?
3What is the upper limit of Low Voltage (Basse Tension - BT) and the boundary where High Voltage (Haute Tension) begins for alternating current?
4What fundamental physical hazard distinguishes high voltage (HT) from low voltage (BT) regarding electrical contact?
5What are the voltage limits for HTA (Haute Tension A) in direct current (DC / courant continu lisse) under standard NF C 18-510?
6When an electric arc occurs in a high-voltage installation, which combination of hazards is instantly generated?
7What is the definition of 'step voltage' (tension de pas) near an uninsulated high-voltage phase fault to ground?
8Why are physiological injuries from high-voltage electric shock fundamentally different and more deceptive than low-voltage shocks?
9What is the primary danger posed by electromagnetic induction on a de-energized, ungrounded high-voltage transmission line?
10Why do disconnected high-voltage underground cables retain a lethal hazard long after opening the circuit breakers?
About the Habilitation Haute Tension Exam
Habilitation Électrique Haute Tension is an employer-issued authorization under Labour Code Articles R.4544-9 to R.4544-11 and NF C 18-510. The symbols distinguish non-electrical operations (H0/H0V), electrical execution (H1/H1V), work leadership (H2/H2V), and high-voltage consignation (HC); there is no HR general-intervention symbol analogous to BR. Listed operations such as H1V/H2V reinforced-vicinity work require the five-year occupational-physician attestation effective from 1 October 2025, while that condition should not be generalized to H0 or every HC assignment. This 92-item English-language MCQ bank covers the named roles and is not an official translation, one combined exam, or a substitute for practical assessment.
Exam sponsor: Employer under NF C 18-510 and Code du travail R.4544-9 to R.4544-11, supported by an internal or external competent trainer. The requirements and fees below concern the certification or admission exam, separate from our free practice resources.
Assessment
Role-specific theoretical questionnaire (evaluating fundamental electrical safety, regulatory knowledge, and symbol boundaries) combined with a hands-on practical evaluation on representative high-voltage equipment (evaluating PPE inspection, safety zone recognition, pole manipulation, VAT, and MALT/CC procedures)
Time Limit
No national duration; training and assessment are adapted to the target symbol, tasks, competence, and environment
Passing Score
At least 70% on the theoretical QCM; practical acceptance requires no major error and no more than two minor errors
Exam / Certification Fees
No central fee; any training and evaluation price is set by the employer or provider
Exam sponsor websiteFees, eligibility, and exam policies can change. Confirm them with the exam sponsor before applying or paying.
Our practice resources: topics covered
We aim to reflect publicly available exam outlines and topic information in our study resources. Coverage, format, and difficulty may differ from the actual exam, and we cannot guarantee that every detail is accurate or current. Confirm exam requirements, fees, and policies with the official exam sponsor.
High-Voltage Domains & Electrical Hazards
HTA and HTB voltage limits, electric arc blast and radiant energy, step/touch potential, capacitive charge retention in HV cables, electromagnetic induction, and physiological burn trauma
Distances, DMA & High-Voltage Zones
Minimum Approach Distance (DMA), voltage and safety margins, DLVS and DLVR boundaries, and Zones 0, 1, 2, and 3, using applicable official tables and operating instructions
H0 / H0V Non-Electrical Operations
Rights and limits of H0 and H0V holders, painting and civil construction inside substations, Chargé de chantier direction, continuous visual surveillance, and Zone 2 reinforcement rules
H1/H1V Execution & H2/H2V Leadership
Execution under H1/H1V, work site leadership under H2/H2V, Autorisation de travail transfer, PEP pre-job briefings, boundary demarcation, and absolute ban on informal troubleshooting (absence of HR)
HC Consignation, VAT & MALT/CC
The 5 mandatory steps of HV consignation: visible isolation, padlocking with warning signs, positive asset identification, VAT with capacitive detector and rule-of-three, and mandatory dual-side MALT/CC grounding
Preparing for the Habilitation Haute Tension Exam
What You Need to Know
- Passing score: At least 70% on the theoretical QCM; practical acceptance requires no major error and no more than two minor errors
- Assessment: Role-specific theoretical questionnaire (evaluating fundamental electrical safety, regulatory knowledge, and symbol boundaries) combined with a hands-on practical evaluation on representative high-voltage equipment (evaluating PPE inspection, safety zone recognition, pole manipulation, VAT, and MALT/CC procedures)
- Time limit: No national duration; training and assessment are adapted to the target symbol, tasks, competence, and environment
- Exam / certification fees: No central fee; any training and evaluation price is set by the employer or provider Official sources
Using Our Practice Resources
- Work through all 92 available questions
- Review every answer and explanation
- Track weak areas and revisit them
- Use our AI tutor for tough concepts
Habilitation Haute Tension: Suggested Study Strategy
Frequently Asked Questions
What is an electrical habilitation in France and who issues it?
An electrical habilitation is the employer's recognition that a worker can safely perform specified operations. A competent internal or external trainer provides an avis après formation; only the employer issues the Titre d'habilitation. Under the rules effective from 1 October 2025, listed operations such as H1V/H2V reinforced-vicinity work also require a five-year occupational-physician attestation of absence of medical contraindications, but this should not be generalized to every symbol.
What are the voltage thresholds defining High Voltage (Haute Tension) in France?
Under standard NF C 18-510, High Voltage is subdivided into two domains: HTA (Haute Tension A) covers alternating voltages from 1,000 V to 50,000 V inclusive (1,500 V to 75,000 V direct current), and HTB (Haute Tension B) covers voltages strictly greater than 50,000 V AC (greater than 75,000 V DC). Below 1,000 V AC is Low Voltage (Basse Tension - BT).
What does each high-voltage habilitation symbol designate?
In NF C 18-510 nomenclature: 'H' stands for Haute Tension. '0' designates non-electrical personnel performing non-electrical work; '1' designates an electrical executant working under supervision; '2' designates a Chargé de travaux (work leader) who organizes and supervises the work; 'C' designates a Chargé de consignation responsible for lockout/tagout; and the letter 'V' indicates authorization to work within the reinforced vicinity zone (Zone 2 / voisinage renforcé HT).
Is there a high-voltage equivalent of the low-voltage 'BR' intervention symbol?
No. NF C 18-510 has no HR general-intervention symbol equivalent to low-voltage BR. High-voltage operations use the symbol matching the role, such as H1/H2 work, HC consignation, HE special operations, or a T live-work title; BR rules must not be transferred to high voltage.
How is the Distance Minimale d'Approche (DMA) calculated in High Voltage?
DMA is the applicable voltage distance plus the safety margin. Workers must use the current NF C 18-510 table and the installation's operating instructions for the nominal voltage rather than an improvised linear shortcut. Crossing inside the DMA enters the high-voltage live-work zone and requires the corresponding specialized authorization and procedure.
What are the 5 sequential steps of a high-voltage consignation (lockout)?
The 5 mandatory chronological steps under NF C 18-510 are: 1) Séparation (visibly disconnecting all electrical power sources using disconnectors or withdrawable breakers); 2) Condamnation (physically locking the isolation devices in the open position with padlocks and warning tags); 3) Identification (positively verifying that the isolated installation is the exact intended work site); 4) VAT (Vérification d'Absence de Tension using a dedicated capacitive detector on an insulating pole, validated by the rule-of-three); and 5) MALT/CC (Mise à la terre et en court-circuit, which is mandatory in high voltage to eliminate residual capacitive charges and induced voltages).
Why is MALT/CC (grounding and short-circuiting) mandatory in high voltage?
Unlike certain low-voltage scenarios where grounding is conditional, MALT/CC is strictly mandatory on both sides of a high-voltage work site. High-voltage cables retain significant capacitive electrostatic charges even after disconnection; adjacent energized transmission lines induce high electromagnetic voltages; and accidental re-energization or lightning strikes would create lethal flashovers without a low-impedance short-circuit path to ground.
What is the recommended validity period for a high-voltage habilitation?
The employer sets the title's validity and reviews whether it remains appropriate. INRS recommends refresher training about every three years for ordinary operations and earlier review after changes in duties, installations, methods, standards, or a prolonged interruption. The five-year health-attestation period for listed operations is separate from habilitation validity.