Career upgrade: Learn practical AI skills for better jobs and higher pay.
Level up
All Practice Exams

100+ Free Dell PPDM Deploy Practice Questions

Pass your Dell PowerProtect Data Manager Deploy 2023 (D-PDM-DY-23) exam on the first try — instant access, no signup required.

✓ No registration✓ No credit card✓ No hidden fees✓ Start practicing immediately
Dell Technologies does not publicly report pass rates Pass Rate
100+ Questions
100% Free
1 / 100
Question 1
Score: 0/0

What is the documented maximum number of external VM Direct engines supported per single vCenter Server in PPDM, and what is the recommended number?

A
B
C
D
to track
2026 Statistics

Key Facts: Dell PPDM Deploy Exam

48

Total Exam Questions

Part 1: 39 MCQs / Part 2: 9 simulations

63% / 66%

Passing Scores

Part 1 / Part 2 minimums

120 min

Time Limit

Pearson VUE delivery

$230

Exam Fee (USD)

Per attempt

21/50/29

Domain Weighting (%)

Deployment / Integration / Administration

May 22, 2026

Successor (D-PDM-DY-01) Launch

D-PDM-DY-23 retires May 21, 2026

The Dell PowerProtect Data Manager Deploy 2023 (D-PDM-DY-23) is a Dell Proven Professional certification with a 48-question, 120-minute exam (39 MCQs in Part 1 plus 9 simulations in Part 2), $230 USD fee through Pearson VUE, and minimum passing scores of 63% on Part 1 and 66% on Part 2. The exam validates skills to deploy, configure, integrate, troubleshoot, and upgrade PPDM across VMware, Hyper-V, AWS, Azure, and GCP, and to protect MS-SQL, Oracle, VM, SAP HANA, MS Exchange, Kubernetes, File System, and NAS workloads. Domain weights are Deployment and Initial Configuration 21%, Integration 50%, and Administration 29%. D-PDM-DY-23 retires on May 21, 2026 and is replaced by D-PDM-DY-01 on May 22, 2026 with essentially the same workload coverage.

Sample Dell PPDM Deploy Practice Questions

Try these sample questions to test your Dell PPDM Deploy exam readiness. Each question includes a detailed explanation. Start the interactive quiz above for the full 100+ question experience with AI tutoring.

1Which two components are deployed as part of the PowerProtect Data Manager (PPDM) virtual appliance during the initial OVA installation?
A.Avamar Data Store and Networker Server
B.PowerProtect Data Manager appliance and an embedded VM Direct (vProxy) protection engine
C.Cyber Recovery Vault and CyberSense analytics engine
D.DD Virtual Edition and DD Boost over Fibre Channel server
Explanation: The PPDM OVA installs the PPDM virtual appliance and automatically deploys an embedded VM Direct (vProxy) engine inside the appliance. Dell recommends adding external VM Direct engines for production because the embedded vProxy has limited parallel-backup capacity.
2An implementation engineer is sizing the PPDM virtual appliance for VMware deployment per Dell's deployment best practices. Which CPU and memory baseline must the ESXi host be able to provide for the PPDM VM?
A.4 vCPU and 16 GB RAM
B.8 vCPU and 18 GB RAM
C.10 vCPU and 18 GB RAM
D.16 vCPU and 64 GB RAM
Explanation: Dell's PPDM Deployment Guide specifies 10 vCPU and 18 GB RAM for the PPDM virtual appliance on VMware. These resources must be reservable on the target ESXi host or cluster, otherwise deployment fails or performance is degraded.
3Per the PowerProtect Data Manager 19.16 Deployment Guide, what is the size of disk 1 and disk 2 of the PPDM virtual appliance on VMware?
A.Disk 1: 100 GB / Disk 2: 500 GB
B.Disk 1: 50 GB / Disk 2: 1 TB
C.Disk 1: 250 GB / Disk 2: 250 GB
D.Disk 1: 59 GB / Disk 2: 98 GB
Explanation: The PPDM 19.16 Deployment Guide specifies Disk 1 = 100 GB and Disk 2 = 500 GB for the appliance, with several smaller disks for service partitions. These values are fixed by the OVA and should not be reduced.
4Which Internet Protocol versions does PowerProtect Data Manager support for the appliance management network according to the deployment best practices guide?
A.IPv4 only
B.IPv6 only
C.Dual-stack IPv4 and IPv6 with NAT64
D.IPv4 with optional IPX fallback
Explanation: The PPDM Deployment Best Practices guide states that the PPDM appliance and its components such as the external VM Direct engine and Search Engine nodes are IPv4 only. Plan management and data IP assignments accordingly.
5On which public-cloud platforms can the PowerProtect Data Manager virtual appliance be directly deployed per the 19.16 Deployment Guide?
A.AWS, Microsoft Azure, and Google Cloud Platform
B.AWS and Oracle Cloud only
C.Azure and IBM Cloud only
D.Alibaba Cloud and Tencent Cloud only
Explanation: The PPDM 19.16 Deployment Guide lists Amazon Web Services, Microsoft Azure, and Google Cloud Platform as the three supported public-cloud deployment targets in addition to on-premises VMware/Hyper-V deployment.
6After downloading the PPDM upgrade package, where in the user interface does an administrator initiate the upgrade workflow?
A.Infrastructure > Asset Sources > Upgrade
B.Protection > Protection Policies > Run Upgrade
C.System Settings > Upgrade
D.Restore > Assets > Upgrade Manager
Explanation: The PPDM upgrade workflow is launched from System Settings > Upgrade. The administrator uploads the validated upgrade package, runs precheck, and then applies the package; the appliance is briefly unavailable during the service restart.
7An engineer must register a Pearson VUE candidate for the current Dell PowerProtect Data Manager Deploy exam. Which exam code is currently active as of May 7, 2026?
A.D-PDM-DY-01
B.D-PDM-DY-23
C.DES-DD23
D.E20-526
Explanation: D-PDM-DY-23 is the active Dell PowerProtect Data Manager Deploy 2023 exam code. Dell has announced that D-PDM-DY-23 retires on May 21, 2026 and that the successor exam D-PDM-DY-01 launches May 22, 2026; until that date, candidates must register for D-PDM-DY-23.
8Which protection storage target type does Dell recommend for production PPDM deployments?
A.Generic NFS share on a Linux server
B.PowerProtect DD series appliance or DD Virtual Edition
C.iSCSI LUN exposed from the PPDM appliance
D.Local VMDKs attached to the PPDM appliance
Explanation: PPDM is designed to use PowerProtect DD series (physical) or DD Virtual Edition appliances as protection storage, leveraging DD Boost for source-side deduplication, replication, retention lock, and Cyber Recovery integration.
9During first-time configuration of a freshly deployed PPDM appliance, what is the documented default initial admin password format?
A.admin / admin
B.admin / changeme
C.admin / DM@<appliance-serial-number>
D.root / Password123!
Explanation: Dell's PPDM appliance documentation and step-by-step demo show that the default initial login is the admin user with the password DM@<appliance serial number>. The admin is forced to set a new password before any other configuration can proceed.
10How many management and data IP addresses does Dell recommend assigning during the PPDM appliance initial network configuration?
A.One management IP and at least two data IPs for redundancy
B.Three management IPs and one data IP
C.A single shared IP for management and data traffic
D.Eight IPs - one per service container
Explanation: Dell's PPDM Appliance Deployment demo recommends one management IP for UI/REST traffic and at least two data IPs across the bonded data interfaces for redundancy and failover. Only the management IP needs forward and reverse DNS records.

About the Dell PPDM Deploy Exam

The Dell PowerProtect Data Manager Deploy 2023 (D-PDM-DY-23) certification validates the skills required to deploy, configure, integrate, troubleshoot, and upgrade a PowerProtect Data Manager (PPDM) solution. The exam covers deployment and initial configuration of the PPDM virtual appliance on VMware, Hyper-V, AWS, Azure, and GCP; integration with eight workloads (MS-SQL, Oracle, VM, SAP HANA, MS Exchange, Kubernetes, File System, and NAS); and administration including protection policies, SLA compliance, the Search Engine, protection rules, reports, disaster recovery, monitoring, and troubleshooting tools. IMPORTANT: Dell has announced that D-PDM-DY-23 retires on May 21, 2026, and the successor exam D-PDM-DY-01 (PowerProtect Data Manager Deploy v2) launches on May 22, 2026. The objective set remains substantially the same (deploy, configure, troubleshoot, integrate, upgrade across the same workload list), so this practice content remains relevant for either exam code.

Assessment

48 questions total: Part 1 has 39 multiple-choice questions; Part 2 has 9 simulation/scenario questions covering deployment, integration with 8 workloads, and administration

Time Limit

120 minutes

Passing Score

63% Part 1 / 66% Part 2

Exam Fee

$230 USD (Dell Technologies / Pearson VUE)

Dell PPDM Deploy Exam Content Outline

21%

PowerProtect Data Manager Deployment and Initial Configuration

Identify PPDM components, list deployment requirements (10 vCPU, 18 GB RAM, IPv4-only, VMware/Hyper-V/AWS/Azure/GCP), upgrade PPDM (precheck + DR backup + System Settings > Upgrade), deploy PPDM via OVA, embedded vs external vProxy (4 vCPU/8 GB), Search Engine node sizing (4 vCPU/8 GB/3x50 GB+1 TB), default credentials and initial network configuration

50%

PowerProtect Data Manager Integration

Backup requirements, configure, back up, and restore for MS-SQL (Microsoft App Agent, application-aware vs Application Direct, port 8443), Oracle (RMAN agent, NTP, blocked self-service replication), VM (VM Direct, HotAdd/NBD/SAN, CBT, Transparent Snapshot Data Mover, Instant Access), SAP HANA (Backint API, hdbbackint in /opt/dpsapps/dbappagent/bin, scale-out parallel processes), MS Exchange (VSS, DAG, RDB mailbox restore), Kubernetes (Velero + dellemc/powerprotect-cproxy, OADP on OpenShift, Velero vSphere Operator 1.4.x for Tanzu, agentless app templates), File System (FS Agent, BBB, FLR), NAS (NDMP for PowerScale and NetApp)

29%

PowerProtect Data Manager Administration

Configure and administer Protection Policies, SLA Compliance, Search Engine cluster, Protection Rules (auto-assign), Reports (protection activity, asset compliance, audit), Disaster Recovery (server DR via DD Boost, hourly auto-backups, Recovery Mode), monitor PPDM (Jobs view, SRS/Auto Support), troubleshooting tools (Log gather/Support Bundle, ppdmctl), retention lock governance vs compliance, Cyber Recovery integration, Cloud DR with DD VE, multi-VLAN virtual networks (VGT mode), and AnyPoint replication topologies

How to Pass the Dell PPDM Deploy Exam

What You Need to Know

  • Passing score: 63% Part 1 / 66% Part 2
  • Assessment: 48 questions total: Part 1 has 39 multiple-choice questions; Part 2 has 9 simulation/scenario questions covering deployment, integration with 8 workloads, and administration
  • Time limit: 120 minutes
  • Exam fee: $230 USD

Keys to Passing

  • Complete 500+ practice questions
  • Score 80%+ consistently before scheduling
  • Focus on highest-weighted sections
  • Use our AI tutor for tough concepts

Dell PPDM Deploy Study Tips from Top Performers

1Memorize the PPDM appliance sizing (10 vCPU, 18 GB RAM, Disk 1 100 GB / Disk 2 500 GB) versus external vProxy (4 vCPU/8 GB, 59 GB + 98 GB) versus Search Engine node (4 vCPU/8 GB, three 50 GB disks + one 1 TB disk). These numbers come up often.
2Know the supported PPDM deployment platforms cold: VMware vSphere, Microsoft Hyper-V on-premises, plus AWS, Azure, and GCP in the cloud. PPDM is IPv4-only.
3For the Integration domain (50% of the exam), build mental flowcharts per workload: how the agent is installed, configure step, backup type (application-aware vs Application Direct vs image-level vs NDMP vs Velero), and restore granularity.
4Memorize that on Kubernetes, dellemc/powerprotect-cproxy is the data-mover image, OADP is the operator on OpenShift, and Velero vSphere Operator 1.4.x is the documented family for Tanzu.
5Practice the difference between Retention Lock Governance (admin-reversible) and Compliance (security-officer-required, downtime to enable, regulatory-grade).
6Get comfortable with PPDM server DR (DD Boost preferred, hourly auto-backups after the initial run, OVA redeploy + Restore Backup, optional Recovery Mode) - it appears in many scenario questions.

Frequently Asked Questions

What is the Dell PowerProtect Data Manager Deploy (D-PDM-DY-23) exam?

D-PDM-DY-23 is a Dell Proven Professional certification that validates skills to deploy, configure, integrate, troubleshoot, and upgrade Dell PowerProtect Data Manager (PPDM). It targets Implementation Engineers and PPDM professionals and covers PPDM deployment on VMware/Hyper-V/AWS/Azure/GCP, integration with MS-SQL, Oracle, VM, SAP HANA, MS Exchange, Kubernetes, File System, and NAS workloads, and administration including protection policies, SLA compliance, Search Engine, protection rules, reports, disaster recovery, monitoring, and troubleshooting tools.

How many questions are on D-PDM-DY-23 and what is the passing score?

The exam has 48 questions total in two parts: Part 1 contains 39 multiple-choice items and Part 2 contains 9 simulation/scenario items. The total time limit is 120 minutes. The minimum passing score is 63% on Part 1 and 66% on Part 2, and both parts must be passed.

How much does the D-PDM-DY-23 exam cost?

The exam costs approximately $230 USD per attempt and is delivered through Pearson VUE, either at a test center or via online proctoring. Dell partners may have access to vouchers and discounts.

What domains does D-PDM-DY-23 cover and how are they weighted?

The exam has three domains: PowerProtect Data Manager Deployment and Initial Configuration (21%), PowerProtect Data Manager Integration (50%), and PowerProtect Data Manager Administration (29%). The Integration domain spans eight workloads (MS-SQL, Oracle, VM, SAP HANA, MS Exchange, Kubernetes, File System, NAS), so candidates should expect deep questions across all of them.

Is D-PDM-DY-23 being replaced by a successor exam?

Yes. Dell has announced that D-PDM-DY-23 retires on May 21, 2026 and that the successor PowerProtect Data Manager Deploy v2 exam (D-PDM-DY-01) launches on May 22, 2026. Dell has stated the certification objectives remain consistent (deploy, configure, troubleshoot, integrate, upgrade) across the same workload list, so this practice content remains relevant for either exam code. Candidates booking before May 21, 2026 should register for D-PDM-DY-23; from May 22, 2026 onward, register for D-PDM-DY-01.

What hardware sizing should I memorize for the PPDM appliance and supporting components?

Memorize three baselines: the PPDM appliance (10 vCPU, 18 GB RAM, Disk 1 100 GB / Disk 2 500 GB plus smaller service disks), the external VM Direct/vProxy engine (4 vCPU at 2 GHz, 8 GB RAM, 59 GB and 98 GB disks), and the Search Engine node (4 vCPU at 2 GHz, 8 GB RAM, three 50 GB disks plus one 1 TB disk). PPDM is IPv4-only and supports up to 25 external vProxies per vCenter (7 recommended).

How should I prepare for D-PDM-DY-23?

Work through Dell's recommended on-demand training (Concepts, Features, Implementation, Administration, Upgrade, Troubleshooting) and the workload integration modules for MS-SQL, Oracle, VM, MS Exchange, SAP HANA, Kubernetes, File System, and NAS. Get hands-on lab time configuring at least one full deployment, several protection policies, server DR, replication, and a couple of restores. Then drill on practice questions across all three domains, with extra emphasis on Integration since it carries half the weight.