All Practice Exams

20+ Free Czech Pressure Inspection Technician Exam Practice Questions

Prepare for the Zkouška revizního technika vyhrazených tlakových zařízení exam with instant access — no signup required.

✓ No registration✓ No credit card✓ No hidden fees✓ Start practicing immediately
20+ Questions
100% Free

Loading practice questions...

Same family resources

Explore More Czech Inspection Technician Qualifications (Revizní technik VTZ)

Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.

2026 Statistics

Key Facts: Czech Pressure Inspection Technician Exam Exam

80% + 80%

Written and oral thresholds

TIČR Internal Rules

At least 5

Oral questions

TIČR Internal Rules

5 years

Certificate validity

Act No. 250/2021 Sb.

CZK 4,600

Examination plus certificate fees

Government fee schedule effective 2025

TIČR administers separate written and oral assessments for the requested RT TZ scope. Both require at least 80%; the oral part has at least five questions. TIČR does not publish a fixed written item count or duration. The certificate is valid for five years, and current total fees are CZK 4,600.

Sample Czech Pressure Inspection Technician Exam Practice Questions

Try these sample questions to test your Czech Pressure Inspection Technician Exam exam readiness. Each question includes a detailed explanation. Start the interactive quiz above for the full 20+ question experience with AI tutoring.

1A new RT TZ certificate is issued by TIČR. Which event fixes the end of its ordinary statutory term?
A.The third anniversary of the examination
B.The fifth anniversary of certificate issuance
C.The tenth anniversary of the application
D.Termination of the holder's current employment
Explanation: The five-year term runs from the certificate's date of issue. Neither the earlier application date nor a later employment change is the statutory starting point.
2Which description matches TIČR's current examination for a pressure-equipment inspection technician?
A.A written test only
B.An oral interview only
C.A written part and a separately assessed oral part
D.A practical welding test with no knowledge assessment
Explanation: TIČR's current Internal Rules require a written part followed by a separately assessed oral part for the requested equipment field and scope.
3A pressure-equipment candidate scores 82% on the TIČR written part but only 75% on the oral part. What is the result?
A.Pass because the written score exceeds 80%
B.Pass because the two results average above 78%
C.Fail because the oral part separately requires at least 80%
D.Fail because both parts require a perfect score
Explanation: The written and oral parts are separately evaluated at the 80% threshold. Passing the written part does not compensate for an oral result below 80%.
4What is the minimum number of randomly selected questions in the TIČR oral examination?
A.Three
B.Four
C.Five
D.Ten
Explanation: The current TIČR Internal Rules require at least five randomly selected oral questions based on the field and scope requested by the applicant.
5Which statement correctly combines TIČR's default examination language and permitted references?
A.The exam is in Czech unless otherwise determined, and printed legislation and technical standards are permitted
B.The exam is always English, and only internet sources are permitted
C.The candidate may choose any language, but all printed references are prohibited
D.The exam is always Slovak, and a prepared answer key is permitted
Explanation: The Internal Rules set Czech as the default examination language unless TIČR determines otherwise and permit printed legal regulations and printed technical standards.
6What is the minimum composition of a TIČR competence-examination commission under Act No. 250/2021 Sb.?
A.One inspector selected by the applicant
B.Two external engineers with no designated chair
C.At least three qualified members, chaired by a TIČR employee
D.Exactly five representatives of the equipment manufacturer
Explanation: The Act requires at least three professionally qualified commission members and provides that the chair is an employee of the authorized organization, TIČR.
7When may an unsuccessful applicant repeat a TIČR inspection-technician examination at the earliest?
A.The next day
B.After exactly one year
C.After at least six months
D.After at least 15 days
Explanation: Act No. 250/2021 Sb. permits a repeat examination after a minimum interval of 15 days from the unsuccessful attempt.
8Which evidence set aligns with TIČR's current guidance for a pressure-equipment inspection-technician applicant?
A.A manufacturer's product catalogue and a list of tools owned
B.Identity and proof of fee payment only
C.Any university diploma and a general character reference
D.Identity, legal-capacity and medical evidence, relevant education and practice, existing certificate if applicable, and a scope-appropriate inspection or practice report
Explanation: TIČR lists identity, legal capacity, medical fitness, relevant education and practice, existing credentials where applicable, and an inspection or practice report corresponding to the requested pressure-equipment scope.
9Which codes identify common TIČR pressure-equipment inspection scopes?
A.NI and NII for stationary pressure vessels, and PK/HK codes for steam and hot-water boiler classes
B.E1 and E2 for pressure vessels, and E3 for boilers
C.A1 and A2 only, with no distinction by equipment type
D.LPS I through IV for all pressure equipment
Explanation: TIČR records pressure-equipment scopes such as NI and NII for stationary pressure-vessel classes and PK/HK codes for classes of steam and hot-water boilers. The certificate limits work to its recorded scope.
10A vessel has maximum allowable pressure above 0.5 bar. Why is that fact alone insufficient to conclude that every requirement for dedicated pressure equipment applies?
A.Because pressure is irrelevant once a vessel has a CE mark
B.Because Government Regulation No. 192/2022 Sb. also defines equipment types, classes, thresholds, and exclusions that must be checked
C.Because only vessel color determines the statutory class
D.Because every pressurized vessel is automatically excluded during its first year
Explanation: Pressure above 0.5 bar is an important entry condition, but the regulation must be read as a whole. Equipment type, volume or output, the relevant class criteria, and express exclusions can change the legal result.

About the Czech Pressure Inspection Technician Exam Exam

The RT TZ examination verifies competence to inspect dedicated pressure equipment within a requested Czech statutory scope, including specified stationary pressure-vessel and steam or hot-water boiler classes. Equipment classification requires the complete criteria and exclusions in Government Regulation No. 192/2022 Sb.; pressure above 0.5 bar alone is not a complete classification analysis. The official assessment is in Czech unless TIČR determines otherwise. This bank is an English-language multiple-choice study adaptation, not an official translation, a reproduction of TIČR items or software, or a substitute for oral, report-based, and practical professional preparation.

Assessment

TIČR separately assesses a software-scored written test and an oral examination. Each part requires at least 80%. The oral part uses at least five randomly selected questions associated with the requested stationary-vessel or steam/hot-water-boiler scope. The examination commission has at least three qualified members and is chaired by a TIČR employee. Printed legislation and printed technical standards are permitted under the current Internal Rules.

Time Limit

Not published by TIČR

Passing Score

At least 80% on the written part and at least 80% on the oral part

Exam Fee

CZK 4,600 total (CZK 4,300 examination fee plus CZK 300 certificate-issuance fee) (Technická inspekce České republiky (TIČR))

Czech Pressure Inspection Technician Exam Exam Content Outline

Not published — varies by requested scope

Statutory framework and certificate scope

Act No. 250/2021 Sb. and Government Regulation No. 192/2022 Sb., including equipment classifications, exclusions, certificate duties, and NI/NII and PK/HK scope boundaries.

Not published — varies by requested scope

Pressure-vessel inspection and reporting

Safe preparation, document review, condition assessment, tests, interval decisions, defects, and inspection-report conclusions.

Not published — varies by requested scope

Boiler operation and inspection

Steam and hot-water boiler operating hazards, pressure parts, safety controls, water treatment, and inspection judgment.

Not published — varies by requested scope

Pressure relief, PED, materials, and NDT

Safety valves and bursting discs, PED classification and proof testing, material condition, degradation, and nondestructive examination.

How to Pass the Czech Pressure Inspection Technician Exam Exam

What You Need to Know

  • Passing score: At least 80% on the written part and at least 80% on the oral part
  • Assessment: TIČR separately assesses a software-scored written test and an oral examination. Each part requires at least 80%. The oral part uses at least five randomly selected questions associated with the requested stationary-vessel or steam/hot-water-boiler scope. The examination commission has at least three qualified members and is chaired by a TIČR employee. Printed legislation and printed technical standards are permitted under the current Internal Rules.
  • Time limit: Not published by TIČR
  • Exam fee: CZK 4,600 total (CZK 4,300 examination fee plus CZK 300 certificate-issuance fee)

Keys to Passing

  • Work through all 20 available questions
  • Review every answer and explanation
  • Track weak areas and revisit them
  • Use our AI tutor for tough concepts

Czech Pressure Inspection Technician Exam Study Tips from Top Performers

1Confirm the precise NI, NII, PK, or HK scope on your application before selecting technical standards to study
2Apply the complete classification rules and exclusions instead of relying on a pressure threshold in isolation
3Prepare and critique a scope-appropriate inspection or practice report and test protocol
4Practice explaining shutdown, interval, relief-device, and pressure-boundary judgments orally in Czech

Frequently Asked Questions

How is the official TIČR examination delivered?

It has a software-scored written part and a separately assessed oral part. The oral part contains at least five randomly selected questions for the requested pressure-equipment field and scope.

What score is required?

The current rules require at least 80% on the written part and at least 80% on the oral part. The results are not averaged.

How many written questions are there, and how long is the exam?

TIČR does not publish a fixed written item count or fixed duration. Candidates should use their invitation and current TIČR instructions rather than unofficial estimates.

In what language is the official exam conducted?

The current Internal Rules state Czech unless TIČR determines otherwise. This resource is an English-language study adaptation, not an official translation.

Which scope does the certificate cover?

The certificate records the approved equipment scope, such as NI/NII stationary pressure vessels or PK/HK steam and hot-water boiler classes. Inspection work must remain within that scope.

What happens after an unsuccessful attempt?

A repeat examination may be taken after at least 15 days.