All Practice Exams

Free Practice Questions for CA Branch 1

Exam-style questions and explanations by OpenExamPrep.

✓ No registration✓ No credit card
100+ Questions
100% Free

Loading practice questions...

Exam Review

Key Facts: CA Branch 1 Exam

100

Practice Questions

OpenExamPrep

150

Exam Questions

CA SPCB / PSI

70%

Passing Score

CA SPCB

$75

Exam Fee

CA SPCB

1 ppm

Reoccupancy Clearance

Vikane label

Branch 1

Fumigation Category

CA SPCB

California Structural Pest Control Board Branch 1 is the fumigation license category covering control of household and wood-destroying pests with poisonous or lethal gases. The computer-based examination is delivered by PSI with 150 multiple-choice items in 2.5 hours and requires 70% to pass; the SPCB examination fee is $75. Branch 1 is distinct from Branch 2 (general pest) and Branch 3 (wood-destroying organisms) and from the Department of Pesticide Regulation's agricultural applicator program. Content centers on sulfuryl fluoride (Vikane) properties and safety (5 ppm worker exposure limit, SCBA above 1 ppm or when the concentration is unknown, ~1 ppm reoccupancy clearance), Fumiguide dosage and the CT product, tarping and sealing, monitoring and aeration, the chloropicrin warning agent, warning-sign posting, and the California Structural Pest Control Act. This free prep includes 100 research-based practice questions with explanations and an AI tutor.

Sample CA Branch 1 Practice Questions

Try these sample questions to review concepts for the CA Branch 1 exam. Each question includes a detailed explanation. Start the interactive quiz above for the full 100+ question experience with AI tutoring.

1Which fumigant is the primary structural fumigant used by California Branch 1 licensees to control drywood termites?
A.Methyl bromide
B.Sulfuryl fluoride
C.Chloropicrin
D.Phosphine
Explanation: Sulfuryl fluoride (sold as Vikane and ProFume) is the standard structural fumigant for drywood termites and other wood-destroying pests in California. Methyl bromide was largely phased out as an ozone-depleting substance, leaving sulfuryl fluoride as the dominant Branch 1 fumigant.
2Sulfuryl fluoride gas has which physical property that makes a warning agent essential?
A.It is bright yellow and visible
B.It is colorless and odorless
C.It has a strong rotten-egg smell
D.It is heavier than mercury vapor
Explanation: Sulfuryl fluoride is a colorless, odorless gas, so occupants cannot detect a leak by sight or smell. Because of this, a warning agent (chloropicrin) with a sharp, irritating odor must be released so people are alerted to the presence of fumigant.
3What is the OSHA permissible exposure limit (PEL) / ACGIH TLV-TWA for sulfuryl fluoride that fumigators must respect for worker exposure?
A.1 ppm
B.5 ppm
C.50 ppm
D.100 ppm
Explanation: The 8-hour time-weighted average exposure limit (OSHA PEL and ACGIH TLV) for sulfuryl fluoride is 5 ppm. The Vikane label is stricter for fumigation work: respiratory protection (SCBA) is required whenever the breathing-zone concentration exceeds 1 ppm or is unknown, which is why concentrations are monitored throughout the operation.
4Above what airborne sulfuryl fluoride concentration does the Vikane label require the use of a self-contained breathing apparatus (SCBA) or supplied-air respirator?
A.1 ppm, or whenever the concentration is unknown
B.5 ppm
C.25 ppm
D.100 ppm
Explanation: The Vikane label (EPA Reg. No. 1015-78, July 2024) states: "Respiratory protection must be worn when the concentration of Vikane in the breathing zone ... exceeds 1 ppm or when the concentration is not known," and that protection must be a NIOSH- or MSHA-approved positive-pressure SCBA or combination air-supplied/SCBA respirator. Air-purifying cartridge respirators are not an option for sulfuryl fluoride.
5Air-purifying cartridge respirators provide which level of protection against sulfuryl fluoride?
A.Complete protection at any concentration
B.No protection because there is no approved cartridge for sulfuryl fluoride at high levels
C.Protection only against the warning agent
D.Protection that increases with concentration
Explanation: There is no air-purifying cartridge that reliably removes sulfuryl fluoride at high concentrations, so cartridge respirators cannot be relied upon for protection inside a charged fumigation. At elevated concentrations only SCBA or supplied air protects the worker, which is why fumigators leave the structure once gas is introduced.
6How does sulfuryl fluoride kill target pests such as drywood termites?
A.By suffocating them with carbon dioxide
B.By disrupting energy metabolism through release of fluoride, blocking cellular energy production
C.By dehydrating their exoskeleton
D.By a contact insecticide residue left on wood
Explanation: Sulfuryl fluoride acts as a metabolic poison: it releases fluoride in the insect's body, interfering with the glycolysis and Krebs-cycle enzymes so cells can no longer produce energy. It works as a gas that penetrates wood, not as a surface residue.
7Because sulfuryl fluoride leaves essentially no residual on treated wood, what is an important limitation a Branch 1 licensee should explain to a customer?
A.The treatment sterilizes the soil for years
B.Fumigation does not prevent future re-infestation by new pests
C.The gas will keep killing insects for months
D.No follow-up inspection is ever needed
Explanation: A fumigation kills the pests present at the time of treatment but leaves no lasting residue, so it provides no protection against a new infestation later. Customers should understand that fumigation is a corrective, not a preventive, treatment and that future inspections may be warranted.
8What is the approximate dosage concentration produced by 4 oz of sulfuryl fluoride per 1,000 cubic feet, a typical drywood-termite rate?
A.96 ppm
B.962 ppm
C.5 ppm
D.9,620 ppm
Explanation: Four ounces of sulfuryl fluoride per 1,000 cubic feet produces roughly 962 ppm, a common dosage range for drywood termites. The precise dosage (oz per 1,000 ft3) is determined with the Fumiguide using temperature, exposure time, and required CT product for the target pest.
9Sulfuryl fluoride gas is heavier than air. What practical fumigation consequence does this have?
A.It rises and concentrates at the roof peak
B.It tends to settle and must be circulated with fans to distribute it evenly
C.It floats away and cannot fill a structure
D.It is unaffected by air movement
Explanation: Because sulfuryl fluoride is denser than air, it tends to settle toward lower levels of a structure. Fumigators use circulating fans during introduction to mix the gas and achieve a uniform concentration throughout the tented space so every void reaches lethal dosage.
10Which historical structural fumigant was phased out largely because it is an ozone-depleting substance regulated under the Montreal Protocol?
A.Sulfuryl fluoride
B.Methyl bromide
C.Chloropicrin
D.Carbon dioxide
Explanation: Methyl bromide is a potent ozone-depleting substance and was phased out for most structural uses under the Montreal Protocol and the Clean Air Act. Sulfuryl fluoride, which does not deplete ozone, became the standard replacement structural fumigant.

About the CA Branch 1 Exam

California Branch 1 is the structural pest control license category for controlling household and wood-destroying pests by fumigation with poisonous or lethal gases. The computer-based exam is delivered through PSI with 150 multiple-choice items in 2.5 hours and requires 70% to pass. It covers sulfuryl fluoride (Vikane) safety, fumigation procedures, tarping and clearance, aeration, the chloropicrin warning agent, and California law.

Exam sponsor: California Structural Pest Control Board (SPCB); examination delivered by PSI Exams. The requirements and fees below concern the certification or admission exam, separate from our free practice resources.

Assessment

150 multiple-choice items in 2.5 hours at a PSI test center; 70% to pass (B&P 8560(g)).

Time Limit

2 hours 30 minutes

Passing Score

70%

Exam / Certification Fees

$75 examination fee paid to the SPCB (license fees separate)

Exam sponsor website

Fees, eligibility, and exam policies can change. Confirm them with the exam sponsor before applying or paying.

Our practice resources: topics covered

We aim to reflect publicly available exam outlines and topic information in our study resources. Coverage, format, and difficulty may differ from the actual exam, and we cannot guarantee that every detail is accurate or current. Confirm exam requirements, fees, and policies with the official exam sponsor.

29%

Fumigation Preparation

Inspecting interior and exterior areas of the structure to prepare for fumigation, choosing the type and placement of fumigation and monitoring equipment (tarps, seals, secondary locks, monitoring lines), and making sure fumigation notices are on site and warning signs are posted to prevent unauthorized entry

17%

Fumigation

Determining the amounts of warning agent (chloropicrin) and fumigant (sulfuryl fluoride) to release with dosage tools such as the Fumiguide, measuring and releasing them, and monitoring the fumigation to prevent leaks and ensure efficacy

12%

Aeration

Methods and procedures for ventilating the structure after fumigation, including active aeration with fans

17%

Certification

Verifying that active aeration time has been achieved, removing tarps and warning-agent pans, confirming the structure is safe for re-entry (breathing-zone clearance of 1 ppm or less with an approved clearance device), removing and posting required signage, and completing fumigation logs

25%

Safety

Worksite safety, including self-contained breathing apparatus (required above 1 ppm sulfuryl fluoride or when the concentration is unknown), CPR, pesticide labels, and personal protective equipment, plus the safe handling, storage, and transportation of fumigants and warning agents

Preparing for the CA Branch 1 Exam

What You Need to Know

  • Passing score: 70%
  • Assessment: 150 multiple-choice items in 2.5 hours at a PSI test center; 70% to pass (B&P 8560(g)).
  • Time limit: 2 hours 30 minutes
  • Exam / certification fees: $75 examination fee paid to the SPCB (license fees separate) Official sources

Using Our Practice Resources

  • Work through all 100 available questions
  • Review every answer and explanation
  • Track weak areas and revisit them
  • Use our AI tutor for tough concepts

CA Branch 1: Suggested Study Strategy

1Memorize the three sulfuryl fluoride numbers: 5 ppm worker exposure limit, SCBA above 1 ppm or when the concentration is unknown, and ~1 ppm reoccupancy clearance
2Know that sulfuryl fluoride is colorless and odorless, so chloropicrin (1 fl oz per 10,000-15,000 ft3) must be added as a warning agent
3Understand the dosage equation: dose is concentration x exposure time (CT product), set with the Fumiguide using temperature and half-loss time
4Study the California sequence: search, secure entries with secondary locks, post signs on all sides, expose, aerate, then clearance-test before reentry
5Review the law: SPCB licensing, 70% passing score via PSI, 24-hour notice to the county agricultural commissioner, and the occupant fumigation disclosure
6Complete all 100 practice questions and review every miss with the AI tutor before sitting the exam

Frequently Asked Questions

How many questions are on the California Branch 1 fumigation exam and what score do I need?

The Branch 1 Field Representative exam has 150 multiple-choice items in 2.5 hours, delivered by computer through PSI, and you need 70% to pass. It focuses on lethal-gas fumigation with sulfuryl fluoride.

What does the California Structural Pest Control Board Branch 1 license cover?

Branch 1 covers the control of household and wood-destroying pests or organisms by fumigation with poisonous or lethal gases. It is distinct from Branch 2 (general pest) and Branch 3 (wood-destroying organisms).

Which fumigant and warning agent are central to Branch 1?

Sulfuryl fluoride (Vikane/ProFume) is the primary structural fumigant; because it is colorless and odorless, chloropicrin is added at about 1 fl oz per 10,000 to 15,000 cubic feet (or the Fumiguide rate) as a warning agent so leaks can be detected.

What are the key sulfuryl fluoride safety numbers I should know?

The 8-hour worker exposure limit (PEL/TLV) is 5 ppm, SCBA is required above 1 ppm or when the concentration is unknown, and the conservative reoccupancy clearance level is about 1 ppm measured with an approved device such as an Interscan or Spectros analyzer.

Who administers the Branch 1 exam and what does it cost?

The SPCB approves applicants and PSI Exams delivers the computer-based examination. The SPCB examination fee is $75; license and renewal fees are separate.

Is this free Branch 1 practice as good as paid prep?

Our 100 practice questions cover the same fumigation safety, procedure, clearance, law, and warning-agent content as the official Branch 1 material, with a teaching explanation for every answer plus free daily AI tutor interactions. All content is free forever and updated for 2026.