Career upgrade: Learn practical AI skills for better jobs and higher pay.
Level up
All Practice Exams

100+ Free Blue Prism Technical Architect Practice Questions

Pass your Blue Prism Technical Architect (TA03, v7) exam on the first try — instant access, no signup required.

✓ No registration✓ No credit card✓ No hidden fees✓ Start practicing immediately
100+ Questions
100% Free
1 / 100
Question 1
Score: 0/0

Which approach is correct when designing Blue Prism integration with a legacy SOAP service that requires WS-Security with a client certificate?

A
B
C
D
to track
Same family resources

Explore More Blue Prism Certifications

Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.

2026 Statistics

Key Facts: Blue Prism Technical Architect Exam

TA03

v7 Exam Code

SS&C Blue Prism

70%

Passing Score

Blue Prism University

60

Exam Questions

SS&C Blue Prism

90 min

Exam Time

SS&C Blue Prism

100+

Practice Questions

OpenExamPrep

Free

Access

OpenExamPrep

The Blue Prism Technical Architect exam (TA03, v7) tests platform and infrastructure design skills for enterprise SS&C Blue Prism v7 deployments. Candidates must design the multi-tier component stack (Interactive Client, Application Server, Runtime Resources, Login Agent, Database, plus the Hub/Interact/Decipher IDP/Capture web tier), integrate the v7 Authentication Gateway with Active Directory and MFA, size SQL Server and choose collation and recovery models, plan capacity for Runtime Resource pools, design HA with SQL Always-On availability groups (sync vs async commit), build DR topologies with defined RPO/RTO, manage TLS certificates and Credential Manager keys, design Dev/Test/Prod/DR environment promotion with .bprelease packages, and deploy on Azure, AWS, GCP, or Citrix/VDI. The exam was refreshed for the v7 platform launch in November 2025 (legacy ATA01/ATA02 retired with v6), is delivered via Certiverse, and targets infrastructure architects and senior platform engineers.

Sample Blue Prism Technical Architect Practice Questions

Try these sample questions to test your Blue Prism Technical Architect exam readiness. Each question includes a detailed explanation. Start the interactive quiz above for the full 100+ question experience with AI tutoring.

1Which Blue Prism v7 component is the .NET service that brokers all communication between Interactive Clients and the database, enforcing authentication and licensing?
A.Interactive Client
B.Application Server
C.Runtime Resource
D.Login Agent
Explanation: The Application Server is the .NET service that brokers connections between Interactive Clients, Runtime Resources, and the database. In v7 it enforces authentication via the Authentication Gateway, applies licensing, and is the recommended connection mode for all clients in enterprise deployments.
2What is the primary purpose of the Login Agent service installed on a Blue Prism Runtime Resource?
A.Authenticate the Blue Prism user against Active Directory
B.Log the Windows OS user in so the Runtime Resource has an interactive session before a human logs on
C.Encrypt credentials in the Credential Manager
D.Route Hub requests to the correct Interact form
Explanation: Login Agent is a Windows service installed on Runtime Resource machines. It performs an interactive Windows logon for the configured OS user so the Runtime Resource service can drive UI applications unattended. Without Login Agent, an unattended Runtime Resource would have no interactive desktop session in which to start automations after a reboot.
3Which collation is required on the SQL Server instance hosting the Blue Prism database?
A.SQL_Latin1_General_CP1_CI_AS
B.Latin1_General_CI_AS
C.Latin1_General_CS_AS
D.Latin1_General_BIN2
Explanation: Blue Prism requires the case-sensitive, accent-sensitive collation Latin1_General_CS_AS for its database. Installing on a server with a case-insensitive default collation (such as SQL_Latin1_General_CP1_CI_AS) will cause object name and metadata mismatches and is unsupported.
4In Blue Prism v7, which web product is designed as the business-user portal for triggering and interacting with automations through forms?
A.Hub
B.Interact
C.Decipher IDP
D.Capture
Explanation: Interact is the v7 business-user web portal. It hosts forms that authenticated users complete to trigger Blue Prism processes and view their submissions and results. Hub, by contrast, is the administrative portal that hosts plugins (such as Control Room, Automation Lifecycle Management, and Interact administration) for technical and operational users.
5Which Blue Prism product is used for intelligent document processing (extracting structured data from invoices, forms, and other documents)?
A.Blue Prism Capture
B.Decipher IDP
C.Interact
D.Hub
Explanation: Decipher IDP is the SS&C Blue Prism intelligent document processing product. It classifies documents, extracts structured data using OCR plus machine learning, and feeds results into Blue Prism processes through dedicated VBOs. Blue Prism Capture is a different product used for process discovery, not document processing.
6Which v7 component centralises authentication and is the OIDC broker used by Hub, Interact, and the Interactive Client?
A.Authentication Gateway
B.Application Server
C.Login Agent
D.IIS Reverse Proxy
Explanation: The Authentication Gateway is the v7 OIDC-based identity broker. Hub, Interact, and the Interactive Client all federate through it, and it integrates with Active Directory, MFA providers, and external identity providers. This is a key v7 architectural change versus v6, which authenticated against the database via the Application Server alone.
7Which encryption scheme algorithm is recommended for protecting credentials at rest in the Blue Prism v7 Credential Manager?
A.DES
B.TripleDES
C.AES-256
D.RC4
Explanation: AES-256 is the recommended encryption scheme for Blue Prism credential and data item encryption. The encryption scheme and its key are configured on the Application Server; legacy algorithms (DES, TripleDES, RC4) are either deprecated or weaker and should not be used for new deployments.
8A customer must guarantee zero data loss within their primary data centre on a Blue Prism database failover. Which SQL Always-On commit mode should they use?
A.Asynchronous commit
B.Synchronous commit
C.Database mirroring witness
D.Log shipping with 5-minute intervals
Explanation: Synchronous commit replicates each transaction to the secondary replica before the primary acknowledges the client, providing zero RPO within the availability group. Asynchronous commit, log shipping, and witness-only configurations all allow some lag and therefore non-zero data loss on failover.
9Which file extension is used by Blue Prism release packages that move processes, objects, and configuration between environments?
A..bpr
B..bpa
C..bprelease
D..bppackage
Explanation: Blue Prism exports release packages as .bprelease files. These contain processes, objects, work queues, credentials (encrypted), environment variables, and schedules selected for export. .bprelease is the canonical artifact promoted from Dev to Test to Production through the release pipeline.
10An architect needs to scale a Blue Prism estate horizontally to process more queue items per hour. Which of the following is the correct horizontal scaling approach?
A.Increase RAM and CPU on the Application Server
B.Add additional Runtime Resources to a resource pool and run more concurrent sessions
C.Increase SQL Server max degree of parallelism
D.Upgrade the Interactive Client workstations
Explanation: Horizontal scaling for Blue Prism means adding more Runtime Resources (bots), grouping them into pools, and assigning more concurrent sessions of the performer process. Vertical scaling (more CPU/RAM on a single host) eventually hits limits; horizontal scaling tracks volume growth more linearly.

About the Blue Prism Technical Architect Exam

The Blue Prism Technical Architect (TA03, v7) certification validates infrastructure and platform engineering expertise for SS&C Blue Prism v7 deployments: multi-tier component architecture, Authentication Gateway, SQL Server sizing, HA/DR with Always-On availability groups, Hub/Interact/Decipher/Capture infrastructure, and cloud topologies.

Questions

60 scored questions

Time Limit

90 minutes

Passing Score

70%

Exam Fee

Included with Blue Prism University subscription (SS&C Blue Prism)

Blue Prism Technical Architect Exam Content Outline

25%

Blue Prism v7 Component Architecture

Interactive Client, Application Server, Runtime Resources, Login Agent, Database, Hub, Interact, Decipher IDP, Capture, Browser Automation

20%

Authentication, Authorisation & Security

Authentication Gateway, Active Directory, SSO, MFA, Credential Manager, encryption schemes, TLS certificates, secret keys

20%

Database, Capacity Planning & Scaling

SQL Server sizing, collation, recovery model, log management, archiving, horizontal vs vertical scaling, Runtime Resource pools

20%

High Availability, DR & Networking

SQL Always-On availability groups, sync vs async commit, active-active vs active-passive, firewalls, VPN, RTO/RPO

15%

Environment Strategy, Release & Operations

Dev/Test/Prod/DR topology, .bprelease promotion, Citrix/VDI deployment, logging, monitoring, cloud (Azure/AWS/GCP), v6 to v7 migration

How to Pass the Blue Prism Technical Architect Exam

What You Need to Know

  • Passing score: 70%
  • Exam length: 60 questions
  • Time limit: 90 minutes
  • Exam fee: Included with Blue Prism University subscription

Keys to Passing

  • Complete 500+ practice questions
  • Score 80%+ consistently before scheduling
  • Focus on highest-weighted sections
  • Use our AI tutor for tough concepts

Blue Prism Technical Architect Study Tips from Top Performers

1Memorise every Blue Prism v7 component and which tier it sits in (presentation, application, data, or web)
2Practise distinguishing Hub (admin portal and plugins) from Interact (business-user web forms triggering processes)
3Distinguish Decipher IDP (document understanding) from Blue Prism Capture (process discovery and recording)
4Know the v7 Authentication Gateway, its OIDC role, and how it integrates with Active Directory and MFA
5Drill SQL Always-On availability group commit modes and how synchronous versus asynchronous commit affects RPO
6Understand Login Agent's exact responsibility and why unattended Runtime Resources need it
7Learn the case-sensitive Latin1_General_CS_AS collation requirement for the Blue Prism database
8Practise capacity sizing: concurrent Runtime Resources, sessions per hour, and Application Server connections

Frequently Asked Questions

What is the Blue Prism Technical Architect (TA03) exam?

The Blue Prism Technical Architect exam (TA03) is the v7-aligned platform architecture certification from SS&C Blue Prism. It replaced the legacy ATA01 and ATA02 exams that retired with v6. The exam validates the ability to design multi-tier Blue Prism v7 infrastructure, integrate Hub, Interact, Decipher IDP, and Capture, plan SQL Server capacity, design HA with Always-On availability groups, build DR topologies, and deploy on premises or in cloud (Azure, AWS, GCP).

What is the difference between TA03 and the older ATA01/ATA02 Blue Prism exams?

ATA01 and ATA02 were the Blue Prism v6 Associate and Professional Technical Architect exams. They retired alongside Blue Prism v6. TA03 is the unified v7 Technical Architect exam, refreshed in November 2025 for the v7 platform launch. The TA03 syllabus includes v7-specific components such as the Authentication Gateway, the updated Hub and Interact web tier, Decipher IDP, and Blue Prism Capture.

What v7 components must a Blue Prism Technical Architect know?

Key v7 components include the Interactive Client (developer/controller workstation), the Application Server (.NET service brokering between clients and database), Runtime Resources (the bots that execute processes), the Login Agent (a Windows service that logs the OS user in so Runtime Resources can start unattended), the SQL Server database, the Web Server hosting Hub and Interact, the Authentication Gateway (v7 OIDC/SSO broker), Decipher IDP, and Blue Prism Capture for process discovery.

How should SQL Server be sized for a Blue Prism v7 deployment?

Use SQL Server Enterprise or Standard with case-sensitive collation Latin1_General_CS_AS (the Blue Prism database requires it), allocate fast SSD storage for data and log files, set the recovery model to Full for production with regular transaction log backups, plan for archive and purge of session and audit logs, and budget capacity using expected concurrent Runtime Resources, sessions per hour, and log verbosity. Hub and Interact use separate databases and should be sized independently.

What is the role of the Login Agent in a Blue Prism Runtime Resource?

The Login Agent is a Windows service installed on each Runtime Resource machine. It listens for a Blue Prism login process that authenticates the Windows user, allowing the Runtime Resource service to start in an interactive session before any human logs in. Login Agent is essential for unattended automation on physical or virtual Runtime Resources because Blue Prism processes that drive UI applications require an interactive Windows session.

How does SQL Always-On availability group commit mode affect Blue Prism HA?

Synchronous commit replicates each transaction to the secondary replica before acknowledging the client, providing zero data loss within the availability group but adding latency proportional to network round-trip time. Asynchronous commit acknowledges the client immediately and replicates asynchronously, giving better throughput but allowing small data loss on failover. Most Blue Prism production deployments use synchronous commit within the primary site and asynchronous commit to a DR site.