TermClick to flip

Basilic vein as a PICC target

Tap to reveal definition
Card 1 of 50Patient Assessment

Filter by Topic

Jump to Card

About These VA-BC Flashcards

These 50 flashcards are designed to help you memorize key terms and definitions for the Vascular Access-Board Certified (VA-BC). Each card shows a term on the front and its definition on the back—the classic flashcard format for vocabulary memorization. Use these alongside our practice questions to build both recall and comprehension.

Topics Covered

Patient Assessment9 cards
Professional Development and EBP4 cards
Device Selection7 cards
Insertion6 cards
Legal and Ethical Considerations4 cards
Preparation5 cards
Care and Maintenance7 cards
Complication Management8 cards

Complete Flashcard Reference

Review every term in this set. Open any term to reveal its definition.

Basilic vein as a PICC target

The basilic vein is often preferred for an upper-arm PICC when it is patent, large enough, and accessible along a safe route. It usually has a straighter course than the cephalic vein.

Cephalic vein limitation

The cephalic vein can narrow and angle sharply near the shoulder. That bend makes catheter advancement harder and increases the chance that a PICC will not reach the desired central tip location.

Catheter-to-vein diameter ratio

For upper-arm PICC insertion, INS sets a ceiling of 45%. Divide catheter outside diameter by vein inside diameter. A higher ratio can reduce blood flow around the catheter and increase thrombosis risk.

Why assess coagulation status before insertion?

Coagulation status helps predict bleeding and hematoma risk during vascular access procedures. Abnormal results may require provider review, device adjustment, or a different insertion plan.

Latex or antiseptic allergy review

Allergy review prevents avoidable reactions to gloves, dressings, securement, or skin prep. A documented allergy should drive product substitution before the tray is opened.

Upper extremity venous path to the SVC

A common route is basilic or brachial to axillary, then subclavian, brachiocephalic, and superior vena cava. Knowing this path helps identify where resistance, looping, or malposition may occur.

Arm history that changes the access plan

Existing lymphedema, thrombosis, a dialysis fistula or graft, and prior axillary node treatment warrant specific review. Use a suitable alternative when possible and protect vessels reserved for dialysis.

Patient history in device planning

Diagnosis, therapy duration, vessel history, renal status, mobility, and home-care needs all affect device selection. The best device is the least invasive one that safely supports the ordered therapy.

Ultrasound vein assessment

Ultrasound confirms vein depth, diameter, compressibility, and nearby arteries or nerves. Compressibility helps distinguish a patent vein from thrombosed or nonusable anatomy.

Using MAGIC in a device-selection policy

MAGIC provides evidence-informed appropriateness ratings. Use them with newer applicable evidence and local outcomes when developing a policy for device selection.

Short peripheral IV best fit

A short peripheral catheter is a good option for brief, peripheral-compatible therapy when veins are adequate. Verify the prescribed infusate and planned duration before choosing it.

Midline catheter boundary

A midline has a peripheral tip. INS considers it for 5–14 days of compatible therapy in hospitalized adults and advises against continuous vesicants, parenteral nutrition and infusates with extreme pH or osmolarity.

PICC indication

A PICC can deliver therapy requiring central access when duration, vessel health, infusate and care setting favor this device. Consider thrombosis risk and future dialysis access.

Non-tunneled CVC

A non-tunneled central venous catheter is used for acute central access, often in critical care or urgent therapy. It is not the preferred long-term outpatient device because infection and dislodgement risks are higher.

Tunneled catheter vs implanted port

A tunneled external catheter provides frequent long-term access without repeated needle puncture. An implanted port sits fully under the skin and is often preferred when intermittent long-term access and lower daily maintenance are priorities.

PICC and future dialysis access

A PICC can injure veins needed for dialysis access. In advanced kidney disease, consult nephrology and the vascular access team before committing upper-arm or central veins. A midline also uses arm veins.

Tunneled cuffed hemodialysis catheter

A tunneled cuffed catheter can provide dialysis access when an AV fistula or graft is unavailable or unsuitable. The cuff helps anchor the catheter. Choose access according to the patient's kidney replacement plan.

Modified Seldinger technique

The sequence is needle access, guidewire, dilator or introducer, then catheter advancement. The guidewire maintains vessel access while the tract is prepared for the final catheter.

Cavoatrial junction tip location

The cavoatrial junction is where the superior vena cava meets the right atrium. INS recommends the lower third of the SVC at or near this junction for upper-body central access, with device-specific exceptions.

Intracavitary ECG tip confirmation

An increasing P wave helps locate the tip as it approaches the cavoatrial junction in patients with a usable P wave. If the ECG signal cannot confirm placement, use an approved alternate method.

Sherlock TLS

Sherlock TLS uses magnetic tracking to show catheter tip direction during advancement and may pair with ECG confirmation. Tracking helps navigation; final acceptability still depends on proper tip confirmation criteria.

Why document insertion details?

Insertion documentation establishes what was placed, where, under what conditions, how tip position was confirmed, and whether complications occurred. Missing details weaken continuity of care and legal defensibility.

Chlorhexidine-alcohol skin prep

CHG-alcohol antisepsis relies on friction and complete drying before puncture or dressing. Inserting through wet antiseptic can reduce effectiveness and may irritate tissue or compromise dressing adhesion.

Maximal sterile barrier precautions

For central venous catheter insertion, maximal sterile barriers include cap, mask, sterile gown, sterile gloves, and a large sterile drape. The goal is to reduce organism transfer at insertion and lower CLABSI risk.

CLABSI insertion bundle

Core measures include hand hygiene, skin antisepsis, maximal sterile barriers and site selection. Review daily whether the line is still needed during maintenance.

Guidewire control during insertion

Keep control of the guidewire until it has been removed. Loss of wire control can allow the wire to migrate into the circulation.

Informed consent before vascular access procedures

Consent requires the patient or representative to understand the procedure, benefits, risks, and alternatives. The consequence is ethical and legal: a technically successful insertion can still be improper if consent was invalid.

Transparent semipermeable membrane dressing interval

For non-neonatal central lines, change the transparent dressing at least every 7 days and immediately if damp, loose, soiled or otherwise compromised.

Gauze dressing interval

For a central catheter site, change sterile gauze every 2 days or earlier if damp, loose or visibly soiled.

Scrub the hub

Needleless connectors must be disinfected before access with adequate friction and contact time. Skipping hub disinfection can directly inoculate organisms into the catheter lumen.

Pulsatile flushing

Pulsatile flushing uses start-stop turbulence to help clear the catheter lumen. It is different from forceful flushing; resistance should prompt assessment rather than higher pressure.

Clamping and disconnecting needleless connectors

Clamping and disconnecting sequence depends on the connector design. Follow its directions for use to limit blood reflux.

Sutureless securement device

A sutureless securement device anchors the catheter without sutures through the skin. It reduces catheter motion and avoids suture-related tissue injury or microbial entry points.

Needleless connector change timing

With a continuous infusion system, change the connector with the primary administration set. Replace it earlier when clinically indicated, including contamination, dysfunction or residual blood, and follow the manufacturer's directions.

Mechanical catheter occlusion

Mechanical occlusion comes from kinking, clamps, tight sutures, malposition, or patient position. The fix is assessment and correction of the mechanical cause, not alteplase as the first move.

Thrombotic catheter occlusion

A clot in or around a catheter can impair withdrawal, infusion or both. Assess mechanical causes and infusate history before using alteplase per the applicable protocol.

Fibrin tail ball-valve effect

A fibrin tail may allow flushing but block blood withdrawal when aspiration pulls it over the catheter opening. The clue is easy infusion with absent or sluggish blood return.

Lipid residue and catheter occlusion

Intravenous lipid can leave deposits in the catheter. Review recent infusates and follow pharmacy and device guidance for suspected nonthrombotic obstruction.

Phlebitis Grade 3 on the INS scale

Grade 3 combines site pain and erythema with streaking and a palpable venous cord. Use the facility's assessment and escalation process when phlebitis is suspected.

Extravasation

Extravasation is leakage of a vesicant into surrounding tissue. It is more dangerous than simple infiltration because tissue injury, blistering, or necrosis can occur without prompt intervention.

Air embolism warning signs

Sudden shortness of breath, hypotension, chest pain or neurologic change during central line manipulation can indicate air embolism. Prevent further air entry and activate emergency response promptly.

Pinch-off syndrome

Pinch-off syndrome occurs when a catheter is compressed between the clavicle and first rib, classically with subclavian routes. Positional occlusion can progress to catheter fracture and embolization.

Evidence-based practice

Evidence-based practice combines best research evidence, clinician expertise, and patient preferences. For VA-BC, it means applying standards while still individualizing access decisions to the patient.

Quality improvement vs research

Quality improvement tests process changes to improve local care outcomes, while research is designed to create generalizable knowledge. The distinction affects review requirements, consent, and how results are used.

Root cause analysis after CLABSI

Root cause analysis looks for system contributors such as supply gaps, training drift, documentation failures, or missed maintenance steps. The goal is prevention, not individual blame.

Professional scope of practice

Scope is defined by licensure, state rules, facility policy, competency, and provider orders. Certification supports expertise but does not automatically authorize procedures outside the clinician's legal or institutional scope.

Right to refuse vascular access

A competent patient may refuse vascular access even when clinicians believe the device is beneficial. The clinician should explain risks, notify the provider, and document the refusal and education provided.

Vascular access documentation

Record objective, relevant findings such as the device, site, patency, patient response and any interventions. Complete records help the next clinician identify complications and act safely.

Infusion rate calculation

For pump rates, divide volume by time: mL per hour = total mL / hours. A wrong rate can underdose therapy, overload the patient, or worsen medication toxicity.

Ultrasound during radial arterial catheter insertion

Real-time ultrasound helps identify the artery and guide needle placement. INS cites improved first-attempt success and fewer insertion attempts compared with palpation.

Frequently Asked Questions

What does the VA-BC exam cover?

The VA-BC exam covers eight blueprint domains: Patient Assessment, Troubleshooting Complications and Interventions, Device Assessment and Selection, Care and Maintenance, Insertion, Preparation, Professional Development and Evidence-Based Practice, and Legal and Ethical Considerations.

How many questions are on the VA-BC exam?

The VA-BC exam contains 150 multiple-choice questions. VACC identifies 125 as scored questions and 25 as unscored pretest questions, with a 2.5-hour testing limit.

What score is needed to pass VA-BC?

The passing standard is a scaled score of 90 on a scale from 30 to 140. It is not a raw percentage because scored forms are equated for difficulty.

Who is eligible for the VA-BC exam?

Candidates must have post-secondary education, hold a healthcare credential in a clinical practice requiring vascular access skills, have at least 1 year of professional experience, and attest that their current practice meets VACC's vascular access activity criteria.

How long is VA-BC certification valid?

VA-BC is valid for three years. Renew by retaking the exam or earning 30 vascular access CE credits during that cycle across more than one year and from more than one source.

What happens if I fail the VA-BC exam?

Apply for the next regularly scheduled exam cycle or a later one. After three consecutive failed attempts, VACC requires a wait of at least one year.