Free Journeyman Plumber Practice Test by State: 2026 Guide
Video
Which Wisconsin agency issues and renews plumber licenses?
Code Administration
Question · Easy
Find 45 plumber practice routes across 44 states and DC, confirm your actual credential and references, and work through source-bounded code and trade-math examples.
Blog
Branch interval
Administration and General Regulations
Flashcard
Which plumbing code does Wisconsin enforce statewide?
In Wisconsin's plumbing code, any pipe that carries wastewater or waterborne wastes.
Sanitary piping
Guess the Term
Chapter 1: Licensing, Exam Rules & Code Administration
1.1 Wisconsin Plumbing Credentials, Scope & Supervision (Ch. 145, SPS 305)
Study guide
What score does SPS 305.09(6)(a) require on each part of a DSPS trades examination?
Read the clue and guess the term in 6 tries.
Game
Where does the building drain end and the building sewer begin?
Per SPS 382.30(5)(a), what is the minimum pitch of a 4-inch horizontal branch drain?
Drainage Systems
Naturally occurring regolith overlying bedrock, as Wisconsin's plumbing code defines it; its texture is the mix of sand, silt and clay.
Sewage disposal
Per Table 382.30-1, what is the drainage fixture unit value of a nonpublic water closet?
Vent stack vs. stack vent
Per SPS 382.30(4)(b), what is the minimum diameter of a gravity flow sanitary building sewer?
Question · Medium
Building ___: the part of the drain system not within or under a building's fully enclosed portion, carrying its discharge to a public main, an onsite treatment system or another point of dispersal.
1.2 The Journeyman Exam: Format, Fees, Retakes & Permitted References
Per SPS 382.35(3)(a), what is the maximum developed length of above-ground horizontal drain piping between cleanouts inside a building?
Swap tiles to line up three of the same term.
Term Match
Flood level rim vs. critical level
Per SPS 382.32(3)(b), what liquid seal depth must a trap provide?
Traps Indirect Waste
Drain or vent pipe that extends vertically one full story or more.
Per Table 382.30-2, how many drainage fixture units may drain through 2-inch drain piping other than a stack?
What do you read off an isometric (riser) drawing on this exam?
Per Table 382.30-4, what is the minimum fitting radius for a horizontal to horizontal change of direction in 4-inch drain piping?
Question · Hard
Abbreviation for the measure of a sink's, toilet's or tub's probable discharge into the waste piping, based on its flow rate, how long one discharge lasts and the time between uses.
1.3 Plan Review, Plan Approval & Product Approvals (SPS 382.20)
Per SPS 382.40(7)(d)2, above what supply pressure must a pressure reducing valve and strainer be installed?
Water Supply
Flip two cards at a time to find matching terms.
Term Pairs
Developed length
Per Table 382.41-1, which assembly may protect a high hazard cross connection?
Cross Connection Control
Fitting, device or piping arrangement that, when properly vented, holds a liquid barrier against sewer gases without materially affecting wastewater flow.
Sewer gas protection
Per SPS 382.40(5)(d)3, where must the sensing element of a water heater temperature and pressure relief valve reach?
Architect's scale: what does 1/4 inch = 1 foot-0 inches mean when you measure a plan?
Per SPS 382.40(7)(f)1, what is the maximum load on 1/2-inch water distribution piping serving 2 or more fixtures?
Trap ___: the vertical distance between the top of a trap's weir and the top of the dip separating its inlet and outlet.
1.4 Testing, Inspection, Maintenance & Repairs (SPS 382.21, 382.22)
Per SPS 384.20(5)(p)2, a dual use potable and space heating system needing hotter water must be limited to what supply temperature?
Find five hidden terms in a grid of letters.
Term Search
IPC 312.2 - drainage and vent WATER test
Per SPS 382.40(3)(c)4, which water heater on a closed water system needs no expansion control?
Part of the plumbing system used to equalize pressures, so siphonage and back pressure do not break trap seals.
Air circulation
Per SPS 382.41(4)(b)1, how high must a standard atmospheric vacuum breaker be set above the flood level rim it serves?
IPC 312.3 - drainage and vent AIR test
Per Table 382.40-1b, what is the total water supply fixture unit value of a nonpublic bathtub with a shower head?
___ vent: the portion of a vent pipe that receives the discharge from other fixtures.
1.5 Code Structure, Key Definitions, Basic Principles & Referenced Standards
Per SPS 382.40(4)(c)1, where must control valves be installed in a public building water distribution system?
Loading more…