Free Journeyman Plumber Practice Test by State: 2026 Guide
Video
Under Virginia tradesman regulations, how soon must a licensed plumber notify the Board for Contractors of a change of address?
Code Administration
Question · Easy
Find 45 plumber practice routes across 44 states and DC, confirm your actual credential and references, and work through source-bounded code and trade-math examples.
Blog
Branch interval
Administration and General Regulations
Flashcard
Which code is the technical basis for plumbing questions on the current Virginia journeyman plumber examination?
Materials Joints
Virginia's regulatory term for any regulated activity, such as plumbing; a license can carry more than one as a designation.
Standards of practice
Guess the Term
Chapter 1: Exam Overview, Virginia Licensing Law & Standards of Practice
1.1 Exam Format, Permitted References & Open-Book Strategy
Study guide
Which statement correctly describes a Virginia tradesman license?
Read the clue and guess the term in 6 tries.
Game
Where does the building drain end and the building sewer begin?
Per the IPC as adopted in Virginia, what is the minimum slope for a 4-inch horizontal drainage pipe?
Drainage Systems
___ promise: one likely to influence, persuade or induce, which Virginia's tradesman rules list as a prohibited act.
Standards of conduct
What is the DFU value for a bathtub without a shower per the IPC?
Vent stack vs. stack vent
Per the IPC, what is the minimum size cleanout required on a 4-inch building drain?
Question · Medium
$210 charge a Virginia tradesman pays to restore a license after the 30-day renewal window.
Renewal and reinstatement
1.2 Definitions, Licensure Requirement & Qualification for the Exam
For a building sewer smaller than 8 inches, what is the maximum permitted spacing between cleanouts?
Swap tiles to line up three of the same term.
Term Match
Flood level rim vs. critical level
Under IPC Table 710.1(2), what is the maximum fixture-unit load for a 2-inch drainage stack serving more than three branch intervals?
Question · Hard
Virginia license level whose holder may plan and lay out installation details and supervise the work of installing and repairing.
Definitions
Which fitting is permitted for connecting a horizontal drainage branch to a horizontal building drain?
What do you read off an isometric (riser) drawing on this exam?
What is the minimum building-drain size for two private flush-tank water closets and two lavatories?
The 240 of formal vocational instruction in a journeyman plumber route are counted in this unit, not in years of practical experience.
Qualification for licensure
1.3 Standards of Practice: Designations, Address Changes & License Use
What minimum residual pressure does IPC Table 604.3 list for a siphonic flushometer-valve water closet?
Water Supply
Flip two cards at a time to find matching terms.
Term Pairs
Developed length
What is the maximum permitted static water pressure in a building water-distribution system?
Monetary penalty the Board may impose for a violation, separate from suspending or refusing to renew a license.
Board remedies
Which assembly protects a potable water system from a high-hazard connection where both backsiphonage and backpressure can occur?
Architect's scale: what does 1/4 inch = 1 foot-0 inches mean when you measure a plan?
What is the highest permitted temperature-relief setting for a storage water-heater T&P relief valve?
Any piping other than a riser, main or stack.
Sanitary piping
1.4 Standards of Conduct, Prohibited Acts & Revocation of Licensure
Regardless of calculated demand, what is the minimum diameter of a water service pipe under the IPC?
Find five hidden terms in a grid of letters.
Term Search
IPC 312.2 - drainage and vent WATER test
What type of valve is required to isolate the water supply to each dwelling unit in a multifamily building?
Any pipe that carries wastewater or waterborne wastes inside a building's waste-removal piping.
Does the IPC establish 120°F as a universal minimum temperature at a residential water-heater outlet?
IPC 312.3 - drainage and vent AIR test
Per the IPC, when must a water hammer arrestor be installed?
Vertical main of soil, waste or vent piping that passes through one or more stories.
Chapter 2: Renewal, USBC Administration & General Regulations
2.1 License Renewal, Continuing Education & Reinstatement
What is the minimum size water supply pipe to a flush valve (flushometer) type water closet per the IPC?
Loading more…