What is the primary purpose of carrying out a periodic inspection of an existing electrical installation?
Periodic Inspection Requirements
Question · Easy
What distinguishes periodic inspection from initial verification?
Outcome 1 - Requirements & Reporting
Flashcard
Which document is produced as the result of a periodic inspection and test?
Condition Reporting Eicr
Document that records whether an existing fixed system is suitable to remain in service after inspection and testing.
Requirements and records
Guess the Term
Chapter 1: Purpose & Statutory Framework of Periodic Inspection
1.1 Statutory Framework & Purpose of Periodic Inspection
Study guide
Cheat sheet
An observation reveals bare live conductors accessible to touch at a damaged socket-outlet. Which classification code should be applied on the EICR?
Observation Classification Codes
Read the clue and guess the term in 6 tries.
Game
Why may an existing installation require periodic inspection and testing?
On an EICR, what does classification code C2 indicate?
Agreed description of what the inspection will cover, recorded before work begins and separate from any limitations.
A circuit complies with an earlier edition of BS 7671 but not the current edition, and presents no danger. Which code is appropriate?
How do statutory and non-statutory documents differ in periodic inspection?
When is the code FI ('Further investigation required') appropriate on an EICR?
Question · Medium
Gear worn or held by a worker, such as insulated gloves or a helmet, used only as the last resort after elimination, substitution, engineering and administrative controls.
Safety management
1.2 BS 7671 Chapter 65 Requirements for Periodic Inspection & Testing
An EICR records two C3 observations and no C1, C2 or FI items. What is the overall assessment of the installation?
Recording Interpreting Results
Swap tiles to line up three of the same term.
Term Match
What must be agreed before the extent and limitations of a periodic inspection are set?
How should the extent of sampling be selected for a periodic inspection?
Sampling
Component fitted to limit transient overvoltages from lightning or switching, which BS 7671 now expects unless the owner declares the risk of damage tolerable.
Periodic inspection
Which standard limitation is pre-printed on the EICR as applying unless specifically agreed otherwise with the client?
Limitations Agreed Scope
What makes a sampling plan defensible during periodic inspection?
Before commencing a periodic inspection, what should the inspector agree and record with the person ordering the work?
Connection of extraneous metalwork to the main earthing terminal to stop a dangerous voltage appearing between it and nearby metal.
1.3 Recommended Inspection Intervals & Trigger Events
What is the recommended maximum interval between periodic inspections for a domestic rented property in England?
Flip two cards at a time to find matching terms.
Term Pairs
Which records support a complete periodic inspection report?
Which location has a recommended maximum period between periodic inspections of 1 year?
Body that declares the external earth fault loop impedance and owns the intake equipment.
Why is there no single prescribed test sequence for every periodic inspection?
Sequence Of Tests
What should a safe system of work establish before periodic inspection begins?
Outcome 2 - Safety Management
What is the minimum acceptable insulation resistance value for a 230 V circuit tested at 500 V DC under BS 7671?
Abbreviated name for the cable core or armour that carries earth fault current back toward the main earthing terminal; steel-wire armour can serve as one if its area is adequate.
Periodic testing
Chapter 2: Visual Inspection & Sampling Procedures
2.1 Visual Inspection Fundamentals on Existing Installations
An insulation resistance test on an existing circuit returns 0.4 MΩ. How should this be classified on the EICR?
Question · Hard
Find five hidden terms in a grid of letters.
Term Search
Why is a voltage indicator proved both before and after proving dead?
When carrying out insulation resistance testing during a periodic inspection of an occupied property, what precaution prevents damage to connected equipment?
Safe Testing Live Installations
Generic name for protective switches that trip when the flow returning through the neutral differs from the flow leaving on the line conductor.
Which instrument and approach is used to safely prove an installation is dead before commencing dead testing?
Who can be harmed when safe isolation is omitted?
What does a measurement of Zs (earth fault loop impedance) confirm on an existing circuit?