Free Journeyman Plumber Practice Test by State: 2026 Guide
Video
Under Texas's adoption of the IPC, what is the minimum size drain pipe permitted for a water closet?
Drainage Systems
Question · Easy
Find 45 plumber practice routes across 44 states and DC, confirm your actual credential and references, and work through source-bounded code and trade-math examples.
Blog
Branch interval
Administration and General Regulations
Flashcard
What is the minimum slope for a 4-inch horizontal drainage pipe in Texas?
Principal artery of a piping system, to which its branches connect.
Definitions
Guess the Term
Chapter 1: Licensing Laws, Board Rules, & Safety
1.1 TSBPE Laws, Board Rules, & Scope of Practice
Study guide
What is the DFU value for a private 1.6 GPF water closet in Texas under the IPC?
Question · Medium
Read the clue and guess the term in 6 tries.
Game
Where does the building drain end and the building sewer begin?
What backflow preventer is required for high-hazard cross-connections in Texas?
Water Supply
Any pipe that carries wastewater or waterborne wastes inside a building's waste-removal piping.
Sanitary piping
What is the minimum trap seal depth in Texas?
Vent stack vs. stack vent
What is the minimum vent pipe size in Texas?
Venting
Abbreviation for the load value given to each sink, toilet or tub, based on how much, how long and how often it discharges, used to size soil and waste piping.
1.2 Responsible Master Plumber (RMP) Supervision & Permitting
What is the maximum static water pressure in Texas?
Swap tiles to line up three of the same term.
Term Match
Flood level rim vs. critical level
When is a cleanout required on horizontal drainage in Texas?
___-connection: any actual or potential link between a potable water system and a source of contamination or pollution.
Backflow prevention
What device must be on every water heater in Texas?
Fixtures Appliances
What do you read off an isometric (riser) drawing on this exam?
What is the max shower/bathtub delivery temperature in Texas?
Air ___: clear vertical distance through open air between the lowest opening of a water outlet and the flood-level rim of the receptacle it fills.
1.3 Jobsite Safety, OSHA Standards, & Trenching
What is the gas piping test requirement in Texas?
Gas Piping
Flip two cards at a time to find matching terms.
Term Pairs
Developed length
What is the DWV rough-in test in Texas?
Code Administration
Water ___: the pressure surge in supply piping when flow is stopped suddenly, which arresters near fast-closing valves absorb.
Water supply
What is the min front clearance for a water closet in Texas?
Architect's scale: what does 1/4 inch = 1 foot-0 inches mean when you measure a plan?
What pipe is NOT approved for underground drainage in Texas?
Materials Joints
Abbreviation for a backsiphonage-only device with a body, a checking member and an air port, installed with no shutoff valve downstream.
1.4 Enforcement, Disciplinary Action, & Penalties
What trap type is prohibited in Texas?
Find five hidden terms in a grid of letters.
Term Search
IPC 312.2 - drainage and vent WATER test
What is the min vent terminal height above a roof in Texas?
Flood-level ___: the top edge of a receptacle from which water overflows.
Plumbing fixtures
What is the min horizontal distance from vent terminal to a window in Texas?
IPC 312.3 - drainage and vent AIR test
What is the min building water service pipe size in Texas?
Trap ___: the vertical distance between a trap's weir and the top of its dip.
Traps
Chapter 2: Exam Format, Adopted Codes, & Definitions
2.1 Exam Format, Scoring, & Testing Logistics
What is the support spacing for horizontal PVC drainage in Texas?
Loading more…