In a basic vapor-compression refrigeration cycle, which component is responsible for absorbing heat from the refrigerated space?
Refrigeration Cycle
Question · Easy
Lockout/tagout, called like a cup final
Short
RETA CARO Exam Guide 2026: Ammonia Safety and Operator Prep
Prepare for RETA CARO in 2026 with current 110-question format, 70% passing score, updated fees, on-screen references, ammonia safety priorities, and free practice.
Blog
Ton of Refrigeration
Refrigeration Fundamentals
Flashcard
Anhydrous ammonia used as a refrigerant in industrial systems is commonly designated as which ASHRAE refrigerant number?
Refrigerant Properties
Amount of heat needed to raise one pound of water by one degree Fahrenheit.
Heat and capacity
Guess the Term
Chapter 1: Refrigeration Fundamentals
1.1 Heat, Temperature, and Pressure
Study guide
Cheat sheet
Which federal regulation requires Process Safety Management for a covered process with at least 10,000 lb of anhydrous ammonia?
Safety Hazards Prevention
Question · Medium
Read the clue and guess the term in 6 tries.
Game
Btu (British Thermal Unit)
During normal operation, what is the correct flow of refrigerant through the four main components of a single-stage vapor-compression cycle starting at the compressor discharge?
Cooling rate of 12,000 Btu per hour.
In a direct-expansion (DX) evaporator, which device meters refrigerant into the coil while controlling outlet superheat?
Lockout/Tagout
Safety, Hazards, and Prevention
The term 'ton of refrigeration' represents approximately how much cooling capacity?
Kind of expansion feed in which all liquid refrigerant turns to vapor before it leaves the coil.
Refrigeration cycle
1.2 Ton of Refrigeration and Temperature Ranges
What does 'saturation' mean in refrigeration tables and system operation?
Saturated Refrigerant Tables
Swap tiles to line up three of the same term.
Term Match
Sensible vs. Latent Heat
Which pair of extinguishing agents does the NIOSH emergency response card list for a small ammonia fire?
Kind of cooling a controlled-pressure receiver performs while also setting feed pressure.
What is the atmospheric-pressure boiling point of anhydrous ammonia?
Superheat
Which common compressor type in industrial ammonia systems uses two meshing helical rotors to compress vapor?
Compressor Types
Kind of positive displacement compressor that squeezes vapor between two intermeshing helical parts.
Compressor types
1.3 Superheat and Subcooling
In a reciprocating ammonia compressor, what is the primary purpose of suction and discharge valves?
Compressor Operation Maintenance
Flip two cards at a time to find matching terms.
Term Pairs
Subcooling
With suction conditions, head pressure and load steady, which reciprocating-compressor fault can raise discharge temperature and reduce capacity?
Compression ___ found by dividing absolute discharge pressure by absolute suction pressure.
Compressor operation
Why is proper oil level maintained in industrial ammonia compressors?
Lubrication
Vapor-Compression Cycle Flow Order
Why do conventional mineral oils carried out of an ammonia compressor collect at low points in low-side vessels?
Kind of volume equal to cylinder area times piston stroke length times rpm.
Chapter 2: Refrigeration Cycle
2.1 Vapor-Compression Cycle Flow and Components
Before starting an ammonia system oil drain, what should an authorized operator use to determine the safe equipment setup?
Find five hidden terms in a grid of letters.
Term Search
Expansion Device (Metering Device)
What makes an off-cycle air defrost effective on a cooler evaporator?
Evaporators Cooling Units
One of the two meshing helical parts of a twin-screw compressor, male if it has lobes and female if it has interlobes.
Heavy frost buildup on an evaporator coil in a freezer room most directly causes which operational problem?
Condenser Heat Rejection Balance