Which Oklahoma state agency oversees fire alarm installer licensing?
State Laws Regulations
Question · Easy
What a Safety Data Sheet tells you
Short
What written examination must an Oklahoma commercial fire alarm technician applicant pass for licensure?
Question · Medium
Oklahoma Licensing Laws & Administrative Authority
1.1 Oklahoma Alarm, Locksmith, and Fire Sprinkler Industry Act (59 O.S. § 1800)
Study guide
How many questions are on the Oklahoma CareerTech Commercial Fire Alarm Technician exam (assessment 4011)?
Trades Exam Prep Podcast
Listen on Spotify
Podcast
What is the fee for an on-site Oklahoma alarm technician or inspector exam?
Which reference materials may Oklahoma fire alarm exam candidates use during the exam?
What valid identification is required to take the Oklahoma fire alarm installer exam?
1.2 Regulatory Authority of the Oklahoma Department of Labor (ODOL)
Under the Oklahoma Alarm, Locksmith, and Fire Sprinkler Act, what license category covers commercial fire alarm installation?
A spot-type heat detector is listed for 50-foot spacing on a smooth ceiling. Before applying any required reductions, what is its maximum center-to-center spacing?
Nfpa Codes
Under NFPA 72, what type of signal does a sprinkler system tamper switch generate?
What does NFPA 72 require regarding the spacing of manual fire alarm boxes in a building?
1.3 Alarm, Locksmith, and Fire Sprinkler Industry Committee
What is the purpose of a Signaling Line Circuit (SLC) in an addressable fire alarm system?
System Design
Per NFPA 72, what is the required candela rating for a wall-mounted strobe in a 30x30 foot room?
Question · Hard
In Oklahoma, severe weather is a significant consideration for fire alarm installations. What must installers account for?
Installation Practices
Under NFPA 72, what must happen before a fire alarm system can be placed in service?
Inspection Testing
1.4 Exam Format, Fees & the ODOL Licensing Path (Assessment 4011)
What is the function of a monitor module in an addressable fire alarm system?
According to NFPA 72 Table 14.3.1, how often must lead-acid (wet cell) or primary dry-cell batteries serving as fire alarm secondary power be visually inspected?
Under NEC Article 760, what is the purpose of listing and labeling requirements for fire alarm equipment?
What is the Oklahoma penalty for installing fire alarm systems without a valid license?
License Classes, Trainee Supervision & Company Rules
2.1 Licensing Classifications — Company, Manager, Technician, Salesperson
Under NFPA 72, what is the minimum number of notification appliances required per notification zone?
What is the main difference between a Class B and Class A circuit in fire alarm systems?
Per NFPA 72, what is the maximum distance a smoke detector can be mounted from the peak of a peaked ceiling?
What type of detector is most appropriate for protecting a commercial kitchen?
2.2 Trainee Licensing, 15-Day Application Window & OSBI Background Checks
Under NFPA 72, what is the required backup power duration for a fire alarm system connected to a central station?
What does NFPA 72 define as the 'authority having jurisdiction' (AHJ)?
According to NEC Article 760, how must fire alarm cables be supported in a vertical run exceeding 100 feet?
Under NFPA 72, what is the purpose of a pre-signal feature on a fire alarm system?
2.3 Trainee Direct Supervision & 3:1 Job Site Ratio Limits
What must an Oklahoma fire alarm company maintain to operate legally?
Under NFPA 72, what type of notification is required in areas where the ambient noise level exceeds 105 dBA?
What is the primary purpose of fire alarm system zoning?
Per NFPA 72, what are the three main types of signals a fire alarm system can generate?
ODOL Operational Compliance, Renewals & Enforcement
3.1 Vehicle Identification Standards & Pocket License Display
Under NFPA 72, what documentation must be left at the fire alarm control panel after system installation?
What does the term 'listed' mean when referring to fire alarm equipment?
Under NFPA 72, what is the maximum zone size for a fire alarm system using conventional detection?
What is a common cause of nuisance alarms in fire alarm systems?
3.2 Annual License Renewal Schedule, Grace Periods & Fees
Per NFPA 72, what type of fire alarm system is required in a building with an automatic sprinkler system?
Under NEC Article 760, fire alarm conductors of different systems may share the same raceway if they are what?
What is the function of an Oklahoma alarm company manager license?
Loading more…