Which OSHA regulation establishes the requirements for the control of hazardous energy (lockout/tagout) that a Level I water-based systems technician must recognize on the job site?
Safety And Hazards
Question · Easy
OSHA fall heights, to scale
Short
A Level I technician arrives to assist with a fire pump inspection and finds the pump controller's electrical disconnect switched off with a padlock and a danger tag attached. What should the technician do?
Question · Medium
Chapter 1: Exam Strategy & Worksite Safety
1.1 NICET ITWBS Level I Exam Overview & Open-Book Strategy
Study guide
Per OSHA 29 CFR 1910.146, a space such as a fire pump wet pit qualifies as a confined space when it meets which set of criteria?
Trades Exam Prep Podcast
Listen on Spotify
Podcast
When a portable extension ladder is used to access an upper landing surface such as a mezzanine where a sprinkler control valve is located, OSHA requires the side rails to extend at least how far above the landing?
A technician sets up a non-self-supporting extension ladder with a working length of 16 feet to reach a riser platform. Following the OSHA 4-to-1 rule, about how far should the base of the ladder be placed from the wall?
Under OSHA's general industry walking-working surfaces rules (29 CFR 1910.28), fall protection is generally required when an employee works on an unprotected edge at or above what height above a lower level?
Question · Hard
1.2 Personal Protective Equipment, Worksite Hazards & Safety Impairments
What does the ground-fault circuit interrupter (GFCI) on a portable electric drill's cord set do for the technician using it?
While inventorying a riser room, a technician finds drums of an unfamiliar chemical additive stored next to the backflow preventer. Where should the technician look for that chemical's hazard and handling information?
Before climbing into a ceiling space, a technician notices a visible crack in the shell of his hard hat. What is the proper action?
Why are sprinkler system control valves commonly secured with a chain and padlock in the open position?
1.3 Hazardous Energy Control: Mechanical & Electrical Lockout/Tagout
Per NFPA 25 (2023), gauges on a wet pipe sprinkler system shall be inspected at what frequency to verify good condition and that normal water supply pressure is maintained?
Gauges And Control Valves
Per NFPA 25 (2023), how often shall the air and water pressure gauges on a dry pipe sprinkler system be inspected?
What does NFPA 25 (2023) require for sprinkler system pressure gauges to ensure their readings stay reliable over time?
How can a technician visually confirm that an OS&Y (outside screw and yoke) control valve is in the open position?
1.4 Ladder Safety, Elevated Work, Hand Tools & GFCI Protection
During a valve inspection, how does a technician confirm that a post indicator valve (PIV) serving an underground supply main is open?
How is the open or closed position of a listed indicating butterfly control valve typically confirmed during inspection?
On an inspection report, the abbreviation WPIV refers to what type of control valve?
NFPA 25 (2023) requires control valves to be inspected weekly, but a valve may instead be inspected at what frequency if it is locked or electrically supervised in accordance with applicable NFPA standards?
Chapter 2: Water Supplies, System Types & Fire Pumps
2.1 Water-Based System Types: Wet, Dry, Preaction & Deluge Systems
Which set of items does the routine (weekly/monthly) control valve inspection under NFPA 25 (2023) Section 13.3.2 verify?
During a monthly gauge inspection on a wet pipe riser, the gauge above the alarm check valve reads 175 psi while the supply gauge below it reads 150 psi. What does this most likely indicate?
Which of the following is NOT a unit of pressure a technician would record from a gauge?
On a dry pipe system riser, the gauge installed on the system side above the dry pipe valve normally indicates what?
2.2 Standpipe Systems: Classes, Types & Component Identification
Per NFPA 25 (2023), the identification sign required at each control valve must indicate what information?
Which of the following is NOT an acceptable method of securing or supervising a sprinkler control valve in its normal position under NFPA 25 (2023)?
Per NFPA 25 (2023) Section 5.2.1, sprinklers shall be inspected from floor level at what frequency?
System Components Inspection
A floor-level inspection finds sprinklers in a woodworking shop coated with a heavy accumulation of sawdust. Per NFPA 25 (2023) Section 5.2.1, what action must be recorded as required?
2.3 Water Supply Identification: Municipal Connections, Gravity & Suction Tanks
During the annual pipe and fittings inspection, a technician sees communication cables zip-tied to a sprinkler branch line. How should this be treated?
How often does NFPA 25 (2023) require sprinkler pipe hangers and seismic braces to be inspected from floor level?
Per NFPA 25 (2023) Section 13.8, fire department connections (FDCs) shall be inspected at what frequency?
During a quarterly FDC inspection, a technician finds one of the 2-1/2 inch caps missing. What does NFPA 25 (2023) require?
2.4 Fire Pump Assemblies: Drivers, Controllers, Casing Relief & System Layout
A building has 250 sprinklers installed. What is the minimum number of spare sprinklers NFPA 25 (2023) requires to be kept in the spare sprinkler cabinet?
The spare sprinkler cabinet must be kept where the ambient temperature does not exceed what value per NFPA 25 (2023)?
Which connection on a sprinkler riser is used both to drain the system and to perform the annual flow test that checks the condition of the water supply?
During a visual external inspection of a double check valve backflow prevention assembly, what should a Level I technician verify?
Chapter 3: System Valves: Control, Drain, Test & Position
3.1 Control Valve Types, Functions & Identification
How often is a wet system alarm valve externally inspected per NFPA 25 (2023), and what does that inspection include?
What is the function of a quick-opening device (QOD), such as an accelerator, installed on a dry pipe system?
Per NFPA 25 (2023) Table 5.1.1.2, alarm devices such as waterflow bells are visually inspected at what frequency to verify they are free of physical damage?