In Maryland, which board oversees stationary engineer licensing for boiler operators?
Md Bo General Knowledge Plant Safety
Question · Easy
Which Maryland body licenses stationary engineers, and where are its rules written?
Maryland Licensing Law
Flashcard
What is the primary function of a safety valve on a steam boiler?
Md Bo Pumps And Valves
Closed container under direct heat in which water is heated and steam generated or superheated, under pressure or vacuum, for use beyond it.
Fundamentals
Guess the Term
Chapter 1: Maryland Stationary Engineer Licensing & Regulations
1.1 Maryland Board of Stationary Engineers & Regulatory Framework
Study guide
Cheat sheet
How many grades of stationary engineer license does Maryland issue?
Read the clue and guess the term in 6 tries.
Game
What activity actually triggers the Maryland stationary engineer license requirement?
What does 'MAWP' stand for in boiler operations?
Heat needed to warm one pound of liquid water by one degree Fahrenheit near its densest point.
In Maryland, what does an applicant for any grade of stationary engineer license have to do?
What is a heating boiler under Maryland law, and why does the definition matter?
What is the purpose of a low-water cutoff on a steam boiler?
Kind of heat that changes water's phase without changing its temperature.
1.2 Five License Grades & Horsepower Limits
What is the correct startup sequence for a cold boiler?
Md Bo Sequential Operations
Question · Medium
Swap tiles to line up three of the same term.
Term Match
A plant runs three 200 HP boilers. Which grade of license does Maryland require?
What causes scale formation in boilers?
Md Bo Water Treatment
SI base unit of electric current, defined by fixing the elementary charge at 1.602 176 634 × 10−19 C.
Basic electricity
Under Maryland rules, how often must a power boiler receive a certificate inspection?
Md Bo Inspections
A facility has no boilers, only large refrigeration compressors and diesel-driven generators. Is a license needed?
What is the ideal pH range for boiler water in a low-pressure steam boiler?
___ marine boiler: the most common type of industrial firetube unit.
Boiler types
1.3 Qualifications, Documented Experience & Exam Requirements
What is the purpose of a flame safeguard control?
Md Bo Burners
Flip two cards at a time to find matching terms.
Term Pairs
What are the penalties for providing or allowing unlicensed stationary engineer service in Maryland?
What type of corrosion is caused by dissolved oxygen in boiler feedwater?
One run of the flue gases along the length of a firetube boiler's pressure vessel; firetube units are described by how many they make.
In Maryland, what equipment does a Grade 5 stationary engineer license authorize?
What horsepower range does each Maryland stationary engineer grade cover?
License Grades and Attendance
What should an operator do if the water level cannot be seen in the gauge glass?
Md Bo Emergency Operations
Firing device that combines fuel and air to initiate combustion; many types exist because fuels differ.
Fuel and combustion
1.4 Maryland Boiler & Pressure Vessel Inspection Laws
What is the purpose of a deaerator in a boiler system?
Find five hidden terms in a grid of letters.
Term Search
In a DC control circuit, how are voltage, current, resistance and power related?
Plant Auxiliaries and Electrical
What prefiring purge does NFPA 85 require before an ignition attempt on a boiler?
Movable device, positioned with the fuel controls to set a fuel-to-air ratio, that regulates air into or out of the combustion chamber.
What is the difference between a firetube and watertube boiler?
Md Bo Boiler Types
How often must the licensee be present when a boiler has NO 24-hour computerized monitoring system?
What is the purpose of bottom blowdown on a steam boiler?
Kind of valve that lets steam leave a boiler but blocks flow back from the header.
Feedwater and valves
Loading more…