Per NEC 90.4, who has the authority to interpret code requirements and approve equipment and materials during a plan review?
General Administration
Question · Easy
14 on 15, 12 on 20, 10 on 30
Short
Which NEC article establishes the definitions used throughout the Code that a plans examiner must apply when reviewing submittal documents?
Chapter 1: General Administration, Plan Review & Code Navigation
1.1 Scope, Administration & the Plans Examiner's Role
Study guide
For a one-family dwelling, NEC 230.79 requires the service disconnecting means to have a rating of not less than what value?
Services
Trades Exam Prep Podcast
Listen on Spotify
Podcast
Per NEC 230.71, the maximum number of service disconnects permitted for each service, each set of service-entrance conductors, or each service drop, permitted to be installed in a single enclosure is limited to how many?
Question · Medium
NEC 230.24(B) requires service-drop conductors passing over residential property and driveways to maintain a minimum vertical clearance of how many feet above final grade?
GFCI inspection
Per NEC 230.70(A)(1), the service disconnecting means must be installed at a readily accessible location either outside the building or inside nearest the point of entrance of service conductors. What is the specific distance requirement when installed inside?
Question · Hard
1.2 Key Definitions & Core Terminology for Plan Examiners
Per NEC 110.26(A)(1), the minimum depth of working space in front of electrical equipment operating at 277 V to ground with exposed live parts on one side and a grounded surface on the other side (Condition 2) is which of the following?
A 400 A service feeds a commercial building. Using NEC 310.12 for dwellings or NEC 310.16 for commercial, what is the minimum size THWN copper service-entrance conductor required for the 400 A commercial service based on Table 310.16 at 75 C?
NEC 310.12 allows a reduced-size service or feeder conductor for a 120/240 V single-phase dwelling when the conductor serves as the main power feeder. This allowance permits the conductor ampacity to be what percentage of the service rating?
Per NEC 250.24(C)(1), the grounded conductor (neutral) brought to the service disconnect must be sized not less than that specified in NEC Table 250.102(C)(1), and in no case smaller than what percentage of the largest ungrounded service conductor?
1.3 Electrical Plan Symbols, Single-Line Diagrams & Schedules
Per NEC 250.52(A), which of the following is NOT listed as a permitted grounding electrode?
Per NEC 250.52(A)(3), a concrete-encased electrode (Ufer ground) must consist of at least 20 feet of what?
Per NEC Table 250.66, what is the minimum size copper grounding electrode conductor required for a service with 3/0 AWG copper ungrounded service-entrance conductors?
Per NEC 250.53(A)(2), supplemental ground rods must be spaced not less than how far apart?
Chapter 2: Services & Service Equipment
2.1 Service Clearances & Approvals
When calculating the service load for a dwelling unit using the standard method in NEC 220.42, the general lighting and receptacle load is calculated at how many volt-amperes per square foot?
Using the NEC 220.42 general lighting demand factor table, what is the demand factor applied to the portion of a dwelling load between 3,001 and 120,000 VA?
Per NEC 220.82 (Optional Method for dwelling units), the first 10 kVA of 'other loads' is calculated at 100%, and the remainder is calculated at what percentage?
Per NEC Table 220.55, the demand factor for a single 12 kW household electric range is what maximum demand?
2.2 Service Conductors & Sizing
Per NEC 220.53, a demand factor of 75% may be applied to the nameplate rating load of how many or more appliances fastened in place (other than ranges, clothes dryers, air conditioning, or space heating) on the same feeder or service in a one-family dwelling?
In a three-phase, 4-wire wye system supplying fluorescent lighting with electronic ballasts, NEC 220.61(C) requires the neutral conductor to be treated as a current-carrying conductor because of what characteristic?
When calculating service load for a dwelling with both electric space heating and air conditioning, NEC 220.82(C) allows the plans examiner to use which load in the calculation?
What is the purpose of a fault current (short-circuit current) calculation required on electrical plans per NEC 110.24?
2.3 Service Disconnecting Means & Equipment
A 1000 kVA, 480Y/277 V transformer has a nameplate impedance of 5.75%. What is the approximate maximum three-phase bolted fault current available at the secondary terminals (assuming an infinite primary)?
Per NEC 240.86, series-rated combinations of circuit breakers and fuses are permitted provided the combination is tested and what marking is applied?
Per NEC 215.2(A)(1), feeder conductors must have an allowable ampacity not less than the noncontinuous load plus what percentage of the continuous load?
Branch Circuit And Feeder
Per NEC 215.3, a feeder overcurrent protective device must have a rating not less than the noncontinuous load plus what percentage of the continuous load?
2.4 Service Overcurrent Protection & Surge Protection
Per NEC 220.40, the calculated load of a feeder or service shall not be less than the sum of the loads on the branch circuits supplied, after any applicable what?
A feeder supplies a bank of fluorescent lighting totaling 38 A and operating continuously. What is the minimum feeder ampacity (before any adjustment or correction) required per NEC 215.2?
Per NEC 220.61(B), the maximum unbalanced load on a 3-wire, 2-wire, or 4-wire feeder may be reduced by what percentage for the portion of a neutral load exceeding 200 amperes (for other than nonlinear loads)?
Per NEC 210.19(A)(1), branch circuit conductors serving continuous and noncontinuous loads must have an ampacity of at least:
Chapter 3: Grounding and Bonding
3.1 Grounding vs. Bonding Fundamentals
Per NEC 210.11(C)(1), a dwelling unit must have at least how many 20 A small-appliance branch circuits supplying the kitchen, pantry, breakfast room, and dining room receptacles?
Per NEC 210.11(C)(2), a dwelling unit must have at least how many 20 A branch circuits for the laundry receptacle outlet?
Per NEC 210.21(B)(1), a single receptacle installed on an individual branch circuit must have an ampere rating not less than what percentage of the branch circuit rating?
Per NEC 240.6(A), which of the following is NOT a standard ampere rating for fuses and inverse time circuit breakers?
3.2 Grounding Electrode System (GES) & Conductors
Per NEC 240.4(D), what is the maximum overcurrent protection permitted for a 14 AWG copper conductor?
Per NEC 240.21(B)(1), feeder tap conductors not over 10 feet long must have an ampacity not less than what fraction of the feeder OCPD rating, or the rating of the device supplied by the tap, whichever is greater?