1.2 Wastewater Operator Certification: Classes 1-4, K, R & Collection System

Key Takeaways

  • Under 35 Ill. Adm. Code 380.115, Illinois sorts municipal wastewater facilities into Groups 1 through 4 by design average flow and process type, plus Group K for industrial treatment and pretreatment works.
  • Municipal operating experience requirements run from 1 year for Class 4 lagoon systems to 6 years for Class 1 systems at 1.0 MGD design average flow or more, and every class except Class 4 sets a hands-on minimum of half the total.
  • Illinois issues three certificates beyond the municipal Classes 1-4: the facility-specific Class K, the general Class R water remediation certificate, and a voluntary Collection System Operator certificate that never expires.
  • Class K and Class R certificates are valid for 5 years, have no renewal process and no continuing education requirement, and are not eligible for reciprocity from another state.
  • Classes 1-4 renew every 3 years: Classes 1 and 2 need 30 continuing education hours (minimum 20 technical), Classes 3 and 4 need 15 hours (minimum 10 technical), and proof-of-training records must be kept 6 years.
Last updated: September 2026

1.2 Wastewater Operator Certification: Classes 1-4, K, R & Collection System

Wastewater operator licensing in Illinois is codified in 35 Ill. Adm. Code Part 380, Procedure for the Certification of Operators of Wastewater Treatment Works. Part 380 is organized into ten subparts, and knowing where a rule lives is itself exam material:

SubpartSectionsSubject
A380.100-380.125Purpose, definitions, facility groups (380.115), certification classification (380.120)
B380.200-380.215Chief Wastewater Operator requirement, required supervision, exceptions, Agency notification
C380.300-380.335Board of Certification
D380.400-380.440Examination
E380.500-380.550Certificate issuance, including Class K (380.525), Class R (380.530) and Collection System (380.535)
F380.600-380.630Sanctions (causes at 380.600, sanctions at 380.615)
G380.700-380.760Certificate renewal, restoration and required training
H380.800-380.810Reciprocity
I380.900-380.925Operator in Training program
J380.1000-380.1025Contractual operation

The Properly Certified Operator

Illinois wastewater rules do not use the drinking water phrase "Responsible Operator in Charge." Subpart B requires each facility to have a Chief Wastewater Operator — the properly certified operator — under the Chief Wastewater Operator Requirement at 35 Ill. Adm. Code 380.205, with required supervision at 380.200, exceptions at 380.210 and Agency notification at 380.215. The requirement is enforced at the facility level:

  • The properly certified operator must hold a certificate at or above the certification level required for that facility group. An Operator-In-Training does not satisfy this requirement.
  • The properly certified operator must exercise direct and active field supervision of the treatment works. Whether physical presence is required depends on the situation, but the operator must know the plant well enough to handle any situation expeditiously and correctly.
  • Under Subpart J, an owner may instead contract for a certified operator. The signed contract must reach the Agency within seven days of its effective date, and the Agency must be notified in writing within seven days if the contract terminates early (35 Ill. Adm. Code 380.1000).

A wastewater operator is defined as a person who regularly makes recommendations or is responsible for process control decisions at a treatment facility. The term does not cover people whose duties are limited to laboratory testing or maintenance, or who exercise only general or indirect supervision.

Facility Groups & Operator Classes (35 Ill. Adm. Code 380.115)

Illinois classifies the facility into a Group, then requires an operator certified at that class or higher. Class 1 is the highest competency level; Class 4 is the entry level.

Group / ClassFacility definitionOperator requiredTotal experienceRenewal
Group 1All domestic wastewater treatment systems with design average flow (DAF) ≥ 1.0 MGD, excluding lagoon systems and primary treatment systemsClass 1 only6 years3 years, 30 CEU hours (min 20 technical)
Group 2Activated sludge systems with DAF < 1.0 MGDClass 2 or Class 14 years3 years, 30 CEU hours (min 20 technical)
Group 3Fixed film processes (stationary and rotating trickling filters, RBCs), Imhoff tank systems and sand filters with DAF < 1.0 MGD, and all primary treatment systemsClass 3, 2 or 12 years3 years, 15 CEU hours (min 10 technical)
Group 4All aerated and non-aerated lagoon treatment systemsClass 4, 3, 2 or 11 year3 years, 15 CEU hours (min 10 technical)
Group KIndustrial wastewater treatment works, pretreatment works, domestic treatment works owned and operated by industry, and collected/discharged spray irrigationClass KActive supervision or operation of the facility5 years, no renewal — re-examine

Exam trap. Collection systems are not Group 4. Lagoons alone define Group 4. Sewer operation and maintenance is covered by a separate, voluntary Collection System Operator certificate issued under 380.535. Another trap: primary treatment systems of any size fall in Group 3, not Group 1, even above 1.0 MGD.

Experience, Education & Substitution Credit

Every applicant must be able to read and write in English, and every class except Class 4 requires high school completion or a GED as a stated minimum eligibility item (Class 4 also lists high school education or equivalent in the Agency's published eligibility summary).

Wastewater operating experience means hands-on physical operation of treatment equipment or processes, direct active field supervision of them, or direct and active involvement in process control decisions — and it may be acquired only at municipal/domestic wastewater treatment facilities. Work that does not count as hands-on operating experience includes public works and street maintenance, meter reading, operating a Vactor truck, sludge hauling or land application, janitorial and grounds keeping, collection system work, drinking water operations, laboratory testing, and electrical or maintenance mechanic work.

Related experience (collection systems, drinking water supplies, or laboratory/maintenance work at a wastewater plant) earns only partial credit, and only once the minimum hands-on requirement has been met.

Substitution is capped by class. These are the Agency's published maxima, and they do not follow a simple degree-for-years formula:

ClassTotal requiredMinimum hands-onMax credit for wastewater coursesOther substitution caps
Class 16 years3 years24 monthsMax 1 year for a wastewater-specific college program that includes operation; max 1 year each for non-wastewater courses and for lab, public water supply, or collection system experience
Class 24 years2 years12 monthsMax 1 year for a wastewater-specific college program; max 1 year each for non-wastewater training and for lab/PWS/collection experience
Class 32 years1 year6 monthsMax 1 year for a wastewater-specific college program; max 1 year non-wastewater training; max 6 months lab/PWS/collection experience
Class 41 year6 months3 monthsMax 1 year for a one-year college program specifically designed for wastewater treatment works operation and including actual operation (such as the ERTC program at SIU Edwardsville); max 3 months lab/PWS/collection experience
Collection System1 year6 months3 monthsMax 3 months of training courses/college or 3 months of lab or public water supply experience

Two working-time conventions matter on the application: 30 hours or more per week counts as full-time, and when experience is reported in hours, 400 work hours = 3 months. Where a job mixes operating and related duties, credit is prorated by the percentage of time spent on each.

Industrial Certificates: Class K vs Class R (380.525, 380.530)

FeatureClass K (facility-specific)Class R (general, water remediation)
ScopeOne named industrial treatment or pretreatment facility, tied to a specific permit and/or locationAll Illinois treatment systems for groundwater contaminated by gasoline, diesel fuel, kerosene, jet fuel or heating oil
Multiple sitesA separate exam and application for each facilityOne certificate covers every qualifying remediation system
Process changeMust re-take and pass the Class K exam if the facility modifies its treatment or pretreatment processn/a
ContaminantsRequired for groundwater contaminated by other substances, such as solventsPetroleum fuels only
Term5 years, no renewal process, no CEUs — re-examine5 years, no renewal process, no CEUs — re-examine
Exam15 questions: 5 multiple choice on basic wastewater mathematics plus 10 short-answer/essay on the applicant's own facility14 questions: 7 multiple choice and 7 short answer/essay
ReciprocityNot eligibleNot eligible

Holding a municipal Class 1 certificate does not authorize operation of an industrial facility; municipal and industrial works have different operating requirements, so a facility-specific Class K is still required.

Class K and Class R candidates should be able to speak to their own plant: flow schematics, the purpose and theory of operation of each treatment unit, removal efficiencies per unit, measures used to prevent and correct process upsets, solids handling and sludge disposal methods, sources and characteristics of raw and treated waste, effluent monitoring requirements, laboratory techniques and result interpretation, safety considerations, applicable rules, recordkeeping, and discharge limits and permit conditions.

Collection System Operator Certificate (380.535)

This certificate is voluntary — but an NPDES permit may require one. There is a single level. Eligibility is 1 year of collection system operating experience (minimum 6 months hands-on, with up to 6 months substituted from wastewater courses or lab, O&M, or public water supply experience), high school education or equivalent, and the ability to read and write English. The exam has 100 questions drawn from Chemical Addition, Collection Systems, Flow Measurement, General Information, Maintenance, Management, Mathematics, Motors, Preliminary Treatment, Pumps and Pumping, Recordkeeping, Rules and Regulations, and Safety. The certificate has no expiration and no CEU requirement.

Examination Logistics & Operator-In-Training Status

  • Fees: there are no fees associated with Illinois wastewater operator certification at present. (Drinking water certification does charge fees — see Section 1.3.)
  • Exam request: submit an Exam Request form at least 30 days before the desired exam date. Expect a Letter of Admission with a schedule in roughly 4 weeks, then call or email the testing site to reserve a seat. You may not simply show up.
  • Testing sites: the 2026 schedule uses the Des Plaines and Rockford regional offices, Illinois EPA headquarters in Springfield, the Marion regional office, and the Environmental Resources Training Center (ERTC) at SIU Edwardsville. Special exams are sometimes offered at conferences.
  • Exam format (Classes 1-4 and Collection System): 100 multiple-choice questions, four answer choices each, maximum 3 hours (9:00 a.m. to 12:00 p.m.). You receive scratch paper, pencils, an answer sheet, and a booklet containing questions, formulas and conversion factors. You may bring only your Letter of Admission, a photo ID, and a non-programmable calculator incapable of storing alphanumeric data. Cell phones and smart watches are barred from the room entirely.
  • Passing score: 70. Results are mailed to the examinee's home address, typically within 30 days (about 8 weeks for Class K), with a per-subject performance breakdown.
  • Level order: you may take any level of exam without passing the lower ones first, and you may test before meeting the experience requirements.
  • Retakes: there is no waiting period, but you must have your results and a valid, unused Letter of Admission. You may schedule only one exam date and location at a time.
  • Operator-In-Training: a score of 70 or higher makes you an Operator-In-Training at that level. The score and OIT status remain effective for 5 years from the date of examination. Choosing a different certification level means taking that level's exam.
  • Full certification: once the minimum experience is obtained, submit the application to the Operator Certification Unit. Review takes up to 90 days, after which the applicant receives a certificate or a denial letter.

Renewal, Restoration & Continuing Education (Subpart G)

Class 1-4 certificates are valid for 3 years from July 1 of the year of issuance. Before July 1 of the expiration year, the operator submits the Agency-issued Renewal Form.

  • Classes 1 and 2: 30 hours of approved continuing education every 3 years, minimum 20 technical hours.
  • Classes 3 and 4: 15 hours every 3 years, minimum 10 technical hours.
  • Collection System, Class K and Class R: no CEU requirement.

Technical topics include activated sludge, aeration, backwash filters, chemical addition, chlorinators, clarifiers, collection systems, digesters, DMRs, disinfection, electrical maintenance, fixed film, Imhoff tanks, instrumentation, intermittent sand filters, lab procedures, lagoons, math, maintenance, operations, oxidation ditches, package aeration, preliminary and primary treatment, reports and records, SCADA, screening, sedimentation, sludge drying beds, sludge handling, land application, sludge presses, and tertiary treatment. Non-technical training includes administration, computers, emergency planning, management, first aid, safety, confined spaces, and wastewater-related weather training.

Two documentation rules are frequently tested. All training must be approved by the Agency — providers or operators may request approval. And operators must keep proof-of-training records for 6 years from the training date, including course name, training provider, instructor or speaker, location, dates, total hours completed, and attendance verification records. The Agency may audit by random selection.

If an operator fails to renew, restoration is available with proof of training within 2 years of the expiration date. Past that, the operator must retake the certification examination and reapply.

Reciprocity (Subpart H)

Illinois grants reciprocity with some other states, depending on the reciprocal state's rules and the applicant's education and employment qualifications. Class R, Class K, Operator-In-Training and Collection System certifications are not eligible for reciprocity from another state.

Sanctions (Subpart F)

Under 35 Ill. Adm. Code 380.600, causes for sanctions include:

  1. Obtaining or attempting to obtain certification by fraud or deceit.
  2. Gross negligence or gross misconduct in operating a treatment or pretreatment facility.
  3. Falsification of records and reports required by the Environmental Protection Act or its rules.
  4. Willful failure to maintain or willful non-submission of required records and reports.
  5. Willful violation of the Act or any rule promulgated under it.
  6. A final civil judgment or criminal conviction for any of the acts above.

Sanctions under 380.615 include prohibiting application for certification, probation, suspension and revocation. A suspended certificate is invalid for up to 18 months, and experience gained during suspension earns no credit toward eligibility. A revoked certificate is invalid, and the operator may not reapply for not less than 18 months and not more than 4 years; at the end of the revocation period the operator must pass the certification examination again.

Test Your Knowledge

Which of the following statements correctly details the regulatory rules governing an Illinois Class K wastewater operator certificate?

A
B
C
D
Test Your Knowledge

An Illinois candidate wants a Class 1 municipal wastewater certificate. What combination of experience does 35 Ill. Adm. Code Part 380 require?

A
B
C
D
Test Your Knowledge

Under 35 Ill. Adm. Code Part 380, what continuing education requirements must Class 1 and Class 2 wastewater operators complete during their 3-year renewal cycle?

A
B
C
D