All Practice Exams

Free Practice Questions for NCQLP LC

Exam-style questions and explanations by OpenExamPrep.

✓ No registration✓ No credit card
100+ Questions
100% Free

Loading practice questions...

Exam Review

Key Facts: NCQLP LC Exam

200

Questions (180 scored)

NCQLP 2026 Candidate Handbook

4 hrs

Exam Time

NCQLP

16-20

5-Question Case Studies

NCQLP

70

Scaled Passing Score (0-99)

NCQLP

$625/$675

2026 U.S./Canada Fee

NCQLP

PSI

Test Center Administrator

NCQLP

The NCQLP LC exam presents 200 multiple-choice questions (180 scored, 20 unscored) in 4 hours at PSI test centers. It includes 100–120 stand-alone questions and 16–20 five-question case studies. The scaled passing score is 70 on a 0–99 scale. In 2026, U.S./Canada fees were $625 early or $675 by the final deadline.

Sample NCQLP LC Practice Questions

Try these sample questions to review concepts for the NCQLP LC exam. Each question includes a detailed explanation. Start the interactive quiz above for the full 100+ question experience with AI tutoring.

1Which photometric quantity describes the luminous flux incident per unit area on a surface, and what is its SI unit?
A.Illuminance, measured in lux
B.Luminance, measured in candelas per square meter
C.Luminous flux, measured in lumens
D.Luminous intensity, measured in candelas
Explanation: Illuminance is the density of luminous flux arriving on a surface, defined as lumens per unit area; the SI unit is the lux (lm/m2) and the IP unit is the footcandle (lm/ft2). It is what light meters read at the work plane.
2A point source produces 25 footcandles on a surface 4 ft directly below it. Using the inverse-square law, what is the illuminance at a point 8 ft directly below the same source?
A.100 footcandles
B.6.25 footcandles
C.12.5 footcandles
D.50 footcandles
Explanation: The inverse-square law states illuminance is proportional to 1/d2. Doubling the distance from 4 ft to 8 ft quarters the illuminance: 25 / (8/4)^2 = 25/4 = 6.25 fc. This applies to a perpendicular surface directly beneath a point source.
3In the lumen (zonal-cavity) method, what does the Coefficient of Utilization (CU) represent?
A.The ratio of luminaire rated lumens to lamp rated lumens
B.The fraction of lamp lumens that reaches the work plane
C.The fraction of luminaire lumens that reaches the work plane, accounting for room geometry and surface reflectances
D.The ratio of maintained to initial illuminance over the cleaning cycle
Explanation: The CU is the fraction of the bare-lamp (or luminaire) lumens that ultimately arrives on the work plane. It depends on luminaire distribution, room cavity ratio, and the reflectances of ceiling, walls, and floor, and is read from manufacturer CU tables.
4Using the lumen method, the number of luminaires required equals (target illuminance x area) divided by which expression?
A.Lumens per luminaire x room cavity ratio
B.Lamp wattage x CU x LLF
C.Lumens per luminaire divided by CU x LLF
D.Lumens per luminaire x CU x LLF
Explanation: N = (E x A) / (lumens per luminaire x CU x LLF). The denominator is the effective maintained lumens each luminaire delivers to the work plane, so dividing the total required lumen-area product by it yields the luminaire count.
5Correlated Color Temperature (CCT) of a white light source is expressed in kelvin. A source rated 2700 K compared with one rated 5000 K will appear:
A.Warmer and more yellow/red
B.Identical in appearance because CRI governs color
C.Greener due to higher duv
D.Cooler and bluer
Explanation: Lower CCT values appear warmer (more yellow/red), while higher CCT values appear cooler (bluer). A 2700 K source resembles incandescent warmth; 5000 K approaches midday daylight. CCT describes chromaticity appearance, independent of color rendering.
6The Color Rendering Index (CRI, Ra) of a light source is determined by:
A.Comparing the chromaticity of the source to a 6500 K daylight standard only
B.Measuring how faithfully the source renders a set of standardized color samples relative to a reference illuminant of the same CCT
C.Averaging the source efficacy across the visible spectrum
D.Counting the number of spectral peaks in the source output
Explanation: CRI (Ra) averages the color-shift of the first eight standardized CIE test color samples when lit by the source versus a reference illuminant of the same CCT (a blackbody below 5000 K or a daylight phase above). A score of 100 indicates no shift.
7Luminous efficacy of a light source is best defined as:
A.The illuminance produced at one meter from the source
B.The total lumens a lamp produces over its rated life
C.The ratio of luminous flux output (lumens) to electrical power input (watts)
D.The fraction of lamp lumens emitted by the luminaire
Explanation: Efficacy is lumens per watt (lm/W), measuring how efficiently a source converts electrical power into visible light. Higher efficacy means lower energy use for a given light output, a key driver of LED adoption and energy-code compliance.
8A luminaire is rated at 5000 lumens. The bare lamps inside are rated at 6250 lumens total. What is the luminaire (fixture) efficiency?
A.0.625
B.0.50
C.1.25
D.0.80
Explanation: Luminaire efficiency = luminaire output lumens / bare-lamp lumens = 5000 / 6250 = 0.80, or 80%. The 20% loss is absorbed by reflectors, lenses, and housing. This ratio is reported in photometric reports as total luminaire efficiency.
9On a candlepower distribution (polar) curve for a luminaire, the radial distance from the center at a given angle represents:
A.Luminous intensity in candelas in that direction
B.Luminance in cd/m2 of the emitting surface
C.Total luminous flux in lumens in that zone
D.Illuminance in footcandles at that angle
Explanation: A candlepower (candela) distribution curve plots luminous intensity versus angle. The radial length at each angle is the candela value emitted in that direction, characterizing whether a luminaire is direct, semi-direct, diffuse, or asymmetric.
10The total Light Loss Factor (LLF) used in maintained-illuminance design is the product of recoverable and nonrecoverable factors. Which of the following is a RECOVERABLE light loss factor?
A.Ballast factor
B.Luminaire Dirt Depreciation (LDD)
C.Voltage-to-luminaire factor
D.Luminaire ambient temperature factor
Explanation: Luminaire Dirt Depreciation (LDD) and Lamp Lumen Depreciation (LLD) and room-surface dirt depreciation are recoverable factors because cleaning or relamping restores output. Nonrecoverable factors (ballast factor, ambient temperature, voltage, tilt) are inherent to the installation.

About the NCQLP LC Exam

The NCQLP Lighting Certified (LC) examination is a 4-hour, closed-book computer-based test of 200 multiple-choice questions (180 scored and 20 unscored pretest items) administered at PSI test centers for the National Council on Qualifications for the Lighting Professions. Section 1 contains 100-120 stand-alone questions across Existing Conditions, Design Phase, and Bidding and Construction Phase; Section 2 contains 16-20 job-related case studies of 5 questions each across Commercial, Institutional, Residential, Industrial, and Exteriors.

Exam sponsor: NCQLP (administered by PSI). The requirements and fees below concern the certification or admission exam, separate from our free practice resources.

Questions

200 questions

Time Limit

4 hours

Passing Score

Scaled score of at least 70 on a 0–99 scale; the raw number needed can vary by form.

Exam / Certification Fees

$625 early or $675 final (U.S./Canada); $725 international; $100 to sit as an eligible Intern LC (2026 fees)

Exam sponsor website

Reported exam pass rate: not-published. A current official first-time pass rate for the 2026 cycle was not found in the candidate materials. Exam sponsor website

Fees, eligibility, and exam policies can change. Confirm them with the exam sponsor before applying or paying.

Our practice resources: topics covered

We aim to reflect publicly available exam outlines and topic information in our study resources. Coverage, format, and difficulty may differ from the actual exam, and we cannot guarantee that every detail is accurate or current. Confirm exam requirements, fees, and policies with the official exam sponsor.

100-120 Qs (Section 1)

Existing Conditions, Design, and Bidding/Construction

Stand-alone questions covering Existing Conditions (at least 25), Design Phase (at least 50), and Bidding and Construction Phase (at least 25)

16-20 Cases / 80-100 Qs (Section 2)

Commercial and Institutional Case Studies

At least five Commercial cases (office, retail, hospitality/entertainment, sports/recreation) and six Institutional cases (education, health care, transport, museums, worship, libraries, government/correctional facilities).

Included in Section 2

Residential, Industrial, and Exteriors Case Studies

At least 1 Residential case study, at least 2 Industrial (manufacturing/warehouse) case studies, and at least 2 Exteriors (site/roadway) case studies

Technical study topics

Calculations, Photometrics, Sources, and Controls

Lumen and point-method calculations, light loss factors, LED LM-79/LM-80/TM-21 metrics, CRI/TM-30, 0-10V/DALI/DMX controls, and daylighting

Project requirements and trade-offs

Codes, Standards, Economics, and Life Safety

ASHRAE/IES 90.1 LPD and controls, NFPA 101 emergency egress lighting, NFPA 70 (NEC), BUG/dark-sky limits, LCCA, and maintenance

Preparing for the NCQLP LC Exam

What You Need to Know

  • Passing score: Scaled score of at least 70 on a 0–99 scale; the raw number needed can vary by form.
  • Exam length: 200 questions
  • Time limit: 4 hours
  • Exam / certification fees: $625 early or $675 final (U.S./Canada); $725 international; $100 to sit as an eligible Intern LC (2026 fees) Official sources

Using Our Practice Resources

  • Work through all 100 available questions
  • Review every answer and explanation
  • Track weak areas and revisit them
  • Use our AI tutor for tough concepts

NCQLP LC: Suggested Study Strategy

1Memorize the photometric quantities and units (lumen, candela, lux/footcandle, cd/m2) and how they relate
2Practice the lumen (zonal-cavity) method end to end, including CU, RCR, and light loss factors
3Drill the point method with the inverse-square and cosine laws on tilted surfaces
4Learn IES recommended practices by application (ANSI/IES RP-1 offices, RP-8 roadway and parking)
5Know ASHRAE 90.1 LPD calculations, automatic shutoff, and daylight-zone control requirements
6Understand LED metrics: efficacy, LM-79, LM-80/TM-21, L70, CRI/TM-30, CCT, and binning
7Approach case studies by fixing the project context once and applying it across all five grouped questions
8Practice unit conversions (1 fc = 10.76 lux) and quick energy-cost/payback calculations

Frequently Asked Questions

How many questions are on the NCQLP LC exam?

200 multiple-choice questions (180 scored, 20 unscored pretest). The exam has 100–120 stand-alone items and 16–20 case studies with five items each. The time limit is 4 hours.

Where do I take the NCQLP LC exam?

The 2026 handbook specifies in-person computer testing at PSI test centers. After NCQLP approves your application and PSI confirms eligibility, schedule with PSI. The exam is closed book. Check the candidate handbook before bringing a calculator.

What topics does the NCQLP LC exam cover?

Section 1 covers Existing Conditions, Design Phase, and Bidding and Construction Phase. Section 2 applies lighting knowledge to commercial, institutional, residential, industrial, and exterior case studies.

What is the passing score for the NCQLP LC exam?

The passing score is 70 on a scale of 0–99; it is not a fixed raw percentage. NCQLP reports a pass/fail result immediately after testing and follows up with a detailed score report by email.

Who can apply for Lighting Certification?

An accredited bachelor’s degree plus at least 3 years of lighting-related work experience, or at least 6 years of lighting-related experience. All applicants must submit two non-family recommendations. The Intern LC pathway lets qualified students or recent graduates test before satisfying the full experience requirement.

How much did the NCQLP LC exam cost in 2026?

Standard U.S. and Canada applicants paid $625 by July 31, 2026, or $675 by September 11, 2026. The international application fee was $725. Eligible interns paid $100 to sit, with a balance due when applying for full LC status. Check NCQLP for the next cycle’s dates and fees.

How do I maintain the LC credential after passing?

Renew every 3 years with 36 Lighting Education Units (LEUs), or 18 LEUs plus documentation of 25 years in lighting. Alternatively, pass the current LC exam in year three.