Key Facts: Iran Nezam Architecture Design Exam Exam
7-8 hours
Approximate Exam Duration
INBR / MRUD
50 / 100 (50%)
Passing Score (clause 6-4, 1405 instruction)
INBR
3 years
Bachelor's Post-Grad Experience Required
IRCEO
Open-Book
Exam Format
INBR
Grade 3
Initial License Grade Awarded
IRCEO
3 years
Validity of an Exam Pass Toward the Licence
INBR
The Iran Nezam Architecture Design examination is the one Nezam Mohandesi paper that is not multiple choice: an open-book, drawing-based (tarsimi) design project lasting roughly 7 to 8 hours, held nationwide under the Office of National Building Regulations. Candidates draw multi-story floor plans, parking bays, ramps, and staircases to INBR Topics 3, 4, 15, 18, 19 and the disability accessibility regulations, and must reach 50 out of 100. Passing supports a Grade 3 (Payeh 3) architectural design practising licence. OpenExamPrep provides independent English-language MCQ practice on the underlying codes.
Sample Iran Nezam Architecture Design Exam Practice Questions
Try these sample questions to review concepts for the Iran Nezam Architecture Design Exam exam. Each question includes a detailed explanation. Start the interactive quiz above for the full 100+ question experience with AI tutoring.
1According to Topic 4 of the Iranian National Building Regulations (INBR), what is the minimum required clear floor-to-ceiling height for habitable spaces in residential buildings?
2INBR Topic 4 fixes a minimum tread depth for stairs and also requires that 2 x riser + tread fall between 63 and 64 cm. Taken together, what maximum riser height do these two rules allow on a common (shared) residential staircase?
3Using the standard ergonomic formula mandated in INBR Topic 4 (2 × Riser + Tread = 63 to 64 cm), if an architect specifies a riser height of 17.5 cm for a public residential staircase, what is the acceptable range for the tread depth?
4Under INBR Topic 4, what is the minimum useful (clear) width of a corridor that forms part of a building's main access route?
5When designing a light well (pasio) to provide natural light and ventilation for primary habitable rooms (such as bedrooms or living rooms) in buildings up to 5 stories high, what is the minimum required horizontal area according to INBR Topic 4?
6What is the minimum horizontal clear floor area and minimum width required for a kitchen providing ventilation and light via a light court in a multi-story residential building under INBR Topic 4?
7Under INBR Topic 4, what is the minimum required height for protective balustrades or guardrails on open residential balconies, roof terraces, and stair landings?
8According to INBR Topic 4, vertical balusters on exterior balconies and open stair guardrails must be spaced such that which of the following objects cannot pass through?
9What is the minimum clear width of an entry door serving a single-family residential unit (apartment entrance door) under INBR Topic 4?
10In multi-story residential buildings, what is the minimum required width of a common public stair flight under INBR Topic 4?
About the Iran Nezam Architecture Design Exam Exam
The Iran Nezam Architecture Design exam is the mandatory practical licensing examination administered by the Ministry of Roads and Urban Development for architects seeking the design (Tarahi) practicing grade in Iran's Construction Engineering Organization. Candidates must produce hand-drafted architectural drawings complying strictly with the Iranian National Building Regulations (Mabahes-e Moghararat-e Melli-ye Sakhteman).
Exam sponsor: Office of National Building Regulations and Building Control (inbr.ir), Ministry of Roads and Urban Development; delivered nationwide by the National Organization for Educational Testing (Sazman-e Sanjesh) educational services company. The requirements and fees below concern the certification or admission exam, separate from our free practice resources.
Assessment
1 full architectural drawing project (site plan, parking layout, residential floor plans, building cross-sections, and egress stair details), held open book
Time Limit
Approximately 7 to 8 hours; not published in the official 1405 registration instruction
Passing Score
50 out of 100 (50%) — clause 6-4 of the official 1405 registration instruction sets this threshold for every discipline and competency
Exam / Certification Fees
Set per sitting and shown in the inbr.ir registration cart; the official 1405 registration instruction does not publish a fixed amount
Exam sponsor websiteFees, eligibility, and exam policies can change. Confirm them with the exam sponsor before applying or paying.
Our practice resources: topics covered
We aim to reflect publicly available exam outlines and topic information in our study resources. Coverage, format, and difficulty may differ from the actual exam, and we cannot guarantee that every detail is accurate or current. Confirm exam requirements, fees, and policies with the official exam sponsor.
General Building Requirements (INBR Topic 4)
Minimum room dimensions, ceiling clearances, corridor widths, light well sizing, ventilation shafts, and spatial planning criteria
Fire Safety & Egress Design (INBR Topic 3)
Egress capacity, maximum travel distances, smoke-proof stair enclosures, fire separations, exit doors, and refuge areas
Parking Layout & Vehicle Circulation
Stall dimensions, maneuvering aisles, vehicular ramp gradients and transitions, head clearances, and column grid placement
Accessibility Standards for Persons with Disabilities
Pedestrian ramp slopes, continuous handrails, accessible entrance thresholds, wheelchair clearance circles, and accessible restrooms
Vertical Transportation & Building Envelope (INBR Topics 15, 18, 19)
Elevator shaft and pit dimensions, stretcher elevator compliance, acoustic insulation between units, and thermal insulation envelope details
Preparing for the Iran Nezam Architecture Design Exam Exam
What You Need to Know
- Passing score: 50 out of 100 (50%) — clause 6-4 of the official 1405 registration instruction sets this threshold for every discipline and competency
- Assessment: 1 full architectural drawing project (site plan, parking layout, residential floor plans, building cross-sections, and egress stair details), held open book
- Time limit: Approximately 7 to 8 hours; not published in the official 1405 registration instruction
- Exam / certification fees: Set per sitting and shown in the inbr.ir registration cart; the official 1405 registration instruction does not publish a fixed amount Official sources
Using Our Practice Resources
- Work through all 100 available questions
- Review every answer and explanation
- Track weak areas and revisit them
- Use our AI tutor for tough concepts
Iran Nezam Architecture Design Exam: Suggested Study Strategy
Frequently Asked Questions
What is the format of the official Iran Nezam Architecture Design exam?
Clause 6-1 of the official 1405 registration instruction states that all Nezam Mohandesi entry-to-profession exams are four-option multiple choice except architecture-design, which is held as a drawing-based (tarsimi) paper lasting roughly 7 to 8 hours. Candidates are given a site lot with specific zoning parameters, street alignments, and floor area ratios, and must draw complete architectural plans including basement parking, ground floor access, typical residential levels, building sections, and egress details. This is an independent English-language MCQ study adaptation by OpenExamPrep covering the underlying technical codes, dimensions, and regulatory calculations — it is not an official translation and does not simulate the drawing paper.
What are the eligibility requirements for the Nezam Architecture Design exam?
Candidates must hold an accredited degree in Architecture approved by the Ministry of Science, Research and Technology. Eligibility requires a minimum post-graduation practical work period: 3 years for Bachelor's degree (Karshenasi) holders, 2 years for Master's degree (Karshenasi Arshad) holders, or 1 year for Ph.D. (Doctora) holders.
What is the passing score for the Architecture Design exam?
Clause 6-4 of the official 1405 registration instruction sets the pass threshold at 50 out of 100 (50%) for every Nezam Mohandesi discipline and competency, including architecture-design. There is no conditional pass: candidates who miss the threshold simply re-sit in a later round. Evaluation is nonetheless demanding, because serious design errors such as failing to provide required parking stalls, creating unventilated habitable rooms, or violating fire egress rules weigh heavily on the marked drawing.
Is the Architecture Design exam open book?
Yes. Clause 6-2 of the official 1405 registration instruction states that the entry-to-profession exams in all disciplines are held open book (ketab baz); only the Article 27 expert-assessment exam is closed book. Candidates may bring official copies of the National Building Regulations (Mabahes), municipal zoning codes, and drafting guides into the examination hall, alongside manual drafting equipment.
Which National Building Regulations (INBR) are tested in Architecture Design?
The primary tested regulations include Topic 3 (Protection of Buildings Against Fire), Topic 4 (General Building Requirements), Topic 15 (Elevators and Escalators), Topic 18 (Acoustic Insulation and Sound Attenuation), Topic 19 (Energy Conservation in Buildings), and the Urban and Architectural Regulations for Persons with Physical Disabilities.