All Practice Exams

Free Practice Questions for Iran Nezam Architecture Design Exam

Exam-style questions and explanations by OpenExamPrep.

✓ No registration✓ No credit card
100+ Questions
100% Free

Loading practice questions...

Same family resources

Explore More Iran Construction Engineering Org Architecture & Planning

Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.

Exam Review

Key Facts: Iran Nezam Architecture Design Exam Exam

7-8 hours

Approximate Exam Duration

INBR / MRUD

50 / 100 (50%)

Passing Score (clause 6-4, 1405 instruction)

INBR

3 years

Bachelor's Post-Grad Experience Required

IRCEO

Open-Book

Exam Format

INBR

Grade 3

Initial License Grade Awarded

IRCEO

3 years

Validity of an Exam Pass Toward the Licence

INBR

The Iran Nezam Architecture Design examination is the one Nezam Mohandesi paper that is not multiple choice: an open-book, drawing-based (tarsimi) design project lasting roughly 7 to 8 hours, held nationwide under the Office of National Building Regulations. Candidates draw multi-story floor plans, parking bays, ramps, and staircases to INBR Topics 3, 4, 15, 18, 19 and the disability accessibility regulations, and must reach 50 out of 100. Passing supports a Grade 3 (Payeh 3) architectural design practising licence. OpenExamPrep provides independent English-language MCQ practice on the underlying codes.

Sample Iran Nezam Architecture Design Exam Practice Questions

Try these sample questions to review concepts for the Iran Nezam Architecture Design Exam exam. Each question includes a detailed explanation. Start the interactive quiz above for the full 100+ question experience with AI tutoring.

1According to Topic 4 of the Iranian National Building Regulations (INBR), what is the minimum required clear floor-to-ceiling height for habitable spaces in residential buildings?
A.2.60 meters
B.2.20 meters
C.2.40 meters
D.2.70 meters
Explanation: INBR Topic 4 (General Building Requirements) establishes that all primary habitable spaces in residential buildings—such as living rooms, bedrooms, and dining spaces—must maintain a minimum clear finished floor-to-ceiling height of 2.40 meters. Secondary spaces such as corridors, bathrooms, and storage rooms are permitted a reduced clearance of 2.10 meters.
2INBR Topic 4 fixes a minimum tread depth for stairs and also requires that 2 x riser + tread fall between 63 and 64 cm. Taken together, what maximum riser height do these two rules allow on a common (shared) residential staircase?
A.Minimum tread of 25 cm, giving a maximum riser of about 20 cm
B.Minimum tread of 30 cm, giving a maximum riser of about 17 cm
C.Minimum tread of 22 cm, giving a maximum riser of about 21 cm
D.Minimum tread of 28 cm, giving a maximum riser of about 18 cm
Explanation: INBR Topic 4 sets the minimum useful tread depth (kaf-e pelleh) at 0.28 m and requires that twice the riser plus the tread lie between 0.63 and 0.64 m. Substituting the minimum tread: 2h = 64 - 28 = 36 cm, so h = 18 cm at the upper bound (and 17.5 cm at the 63 cm bound). The proportioning rule and the minimum tread therefore cap a shared residential stair at roughly an 18 cm riser.
3Using the standard ergonomic formula mandated in INBR Topic 4 (2 × Riser + Tread = 63 to 64 cm), if an architect specifies a riser height of 17.5 cm for a public residential staircase, what is the acceptable range for the tread depth?
A.26.0 cm to 27.0 cm
B.28.0 cm to 29.0 cm
C.30.0 cm to 31.0 cm
D.32.0 cm to 33.0 cm
Explanation: Applying the formula 2h + b = 63 to 64 cm: 2 × 17.5 cm = 35.0 cm. Subtracting this from 63 cm yields b = 28.0 cm, and subtracting from 64 cm yields b = 29.0 cm. Both values satisfy the minimum required public tread depth of 28 cm under INBR Topic 4.
4Under INBR Topic 4, what is the minimum useful (clear) width of a corridor that forms part of a building's main access route?
A.1.40 meters
B.1.10 meters
C.1.20 meters
D.0.90 meters
Explanation: INBR Topic 4 requires corridors on the main access route to have a minimum useful width of 1.40 meters. Topic 4 allows this to drop, as far as 0.90 meters, only in its defined exceptional cases, such as a low occupant load or a route on which accessible access is not required. Inside an individual dwelling unit the minimum corridor width is 0.90 meters.
5When designing a light well (pasio) to provide natural light and ventilation for primary habitable rooms (such as bedrooms or living rooms) in buildings up to 5 stories high, what is the minimum required horizontal area according to INBR Topic 4?
A.4 square meters with a minimum dimension of 1.5 meters
B.9 square meters with a minimum dimension of 2.5 meters
C.6 square meters with a minimum dimension of 2.0 meters
D.12 square meters with a minimum dimension of 3.0 meters
Explanation: INBR Topic 4 mandates that when a light court (pasio) illuminates primary habitable spaces (living rooms and bedrooms) in buildings up to 5 stories, its horizontal clear surface area must be at least 12 square meters, with no horizontal dimension less than 3.0 meters. For secondary spaces like kitchens, the minimum area is 6 square meters with a minimum dimension of 2.0 meters.
6What is the minimum horizontal clear floor area and minimum width required for a kitchen providing ventilation and light via a light court in a multi-story residential building under INBR Topic 4?
A.6.0 square meters area with a minimum clear width of 2.0 meters
B.5.0 square meters area with a minimum clear width of 1.6 meters
C.5.5 square meters area with a minimum clear width of 1.8 meters
D.4.5 square meters area with a minimum clear width of 1.5 meters
Explanation: INBR Topic 4's rules for cooking spaces and kitchens set a minimum floor area of 5.5 square meters and a minimum clear width of 1.80 meters between finished wall faces, plus unobstructed working space in front of the counter run. An independent (closed) kitchen must also receive natural light; open and wall-type kitchens may rely on artificial light with mandatory mechanical extraction.
7Under INBR Topic 4, what is the minimum required height for protective balustrades or guardrails on open residential balconies, roof terraces, and stair landings?
A.1.00 meter
B.0.90 meters
C.1.10 meters
D.1.20 meters
Explanation: INBR Topic 4 requires that guardrails and balustrades on elevated walking surfaces, exterior balconies, roof terraces, and stair landings must have a minimum finished vertical height of 1.10 meters. For internal staircases, handrails are typically set at 0.90 meters, but outer edge perimeter fall-protection must meet the 1.10-meter standard.
8According to INBR Topic 4, vertical balusters on exterior balconies and open stair guardrails must be spaced such that which of the following objects cannot pass through?
A.A sphere with a diameter of 12 cm
B.A sphere with a diameter of 10 cm
C.A sphere with a diameter of 15 cm
D.A sphere with a diameter of 11 cm
Explanation: INBR Topic 4 specifies that openings in protective railings and balustrades must not allow the passage of a sphere with a diameter of 11 cm (110 mm) to prevent infants and small children from slipping through or becoming trapped.
9What is the minimum clear width of an entry door serving a single-family residential unit (apartment entrance door) under INBR Topic 4?
A.0.80 meters
B.0.90 meters
C.1.00 meter
D.0.75 meters
Explanation: INBR Topic 4 requires apartment unit main entrance doors to have a minimum clear opening width of 0.90 meters (allowing convenient entry, furniture moving, and emergency access). Internal bedroom doors require a minimum of 0.80 meters, and bathroom doors require 0.70 meters.
10In multi-story residential buildings, what is the minimum required width of a common public stair flight under INBR Topic 4?
A.1.20 meters
B.0.90 meters
C.1.10 meters
D.1.40 meters
Explanation: Under INBR Topic 4, common public stairs in multi-family residential buildings serving more than two dwelling units must maintain a minimum clear width of 1.10 meters between finished walls or between a wall and a handrail. In buildings with more than 50 occupants, wider flights may be required by egress load calculations.

About the Iran Nezam Architecture Design Exam Exam

The Iran Nezam Architecture Design exam is the mandatory practical licensing examination administered by the Ministry of Roads and Urban Development for architects seeking the design (Tarahi) practicing grade in Iran's Construction Engineering Organization. Candidates must produce hand-drafted architectural drawings complying strictly with the Iranian National Building Regulations (Mabahes-e Moghararat-e Melli-ye Sakhteman).

Exam sponsor: Office of National Building Regulations and Building Control (inbr.ir), Ministry of Roads and Urban Development; delivered nationwide by the National Organization for Educational Testing (Sazman-e Sanjesh) educational services company. The requirements and fees below concern the certification or admission exam, separate from our free practice resources.

Assessment

1 full architectural drawing project (site plan, parking layout, residential floor plans, building cross-sections, and egress stair details), held open book

Time Limit

Approximately 7 to 8 hours; not published in the official 1405 registration instruction

Passing Score

50 out of 100 (50%) — clause 6-4 of the official 1405 registration instruction sets this threshold for every discipline and competency

Exam / Certification Fees

Set per sitting and shown in the inbr.ir registration cart; the official 1405 registration instruction does not publish a fixed amount

Exam sponsor website

Fees, eligibility, and exam policies can change. Confirm them with the exam sponsor before applying or paying.

Our practice resources: topics covered

We aim to reflect publicly available exam outlines and topic information in our study resources. Coverage, format, and difficulty may differ from the actual exam, and we cannot guarantee that every detail is accurate or current. Confirm exam requirements, fees, and policies with the official exam sponsor.

25%

General Building Requirements (INBR Topic 4)

Minimum room dimensions, ceiling clearances, corridor widths, light well sizing, ventilation shafts, and spatial planning criteria

25%

Fire Safety & Egress Design (INBR Topic 3)

Egress capacity, maximum travel distances, smoke-proof stair enclosures, fire separations, exit doors, and refuge areas

20%

Parking Layout & Vehicle Circulation

Stall dimensions, maneuvering aisles, vehicular ramp gradients and transitions, head clearances, and column grid placement

15%

Accessibility Standards for Persons with Disabilities

Pedestrian ramp slopes, continuous handrails, accessible entrance thresholds, wheelchair clearance circles, and accessible restrooms

15%

Vertical Transportation & Building Envelope (INBR Topics 15, 18, 19)

Elevator shaft and pit dimensions, stretcher elevator compliance, acoustic insulation between units, and thermal insulation envelope details

Preparing for the Iran Nezam Architecture Design Exam Exam

What You Need to Know

  • Passing score: 50 out of 100 (50%) — clause 6-4 of the official 1405 registration instruction sets this threshold for every discipline and competency
  • Assessment: 1 full architectural drawing project (site plan, parking layout, residential floor plans, building cross-sections, and egress stair details), held open book
  • Time limit: Approximately 7 to 8 hours; not published in the official 1405 registration instruction
  • Exam / certification fees: Set per sitting and shown in the inbr.ir registration cart; the official 1405 registration instruction does not publish a fixed amount Official sources

Using Our Practice Resources

  • Work through all 100 available questions
  • Review every answer and explanation
  • Track weak areas and revisit them
  • Use our AI tutor for tough concepts

Iran Nezam Architecture Design Exam: Suggested Study Strategy

1Master INBR Topic 4 dimensional tables for minimum clear widths of corridors, stairs, door openings, and light courts
2Memorize standard parking stall dimensions (5.0m x 2.5m for single stalls, 4.5m width for two stalls between columns) and ramp slope limits (maximum 15% to 17%)
3Understand fire stair enclosure rules and maximum exit access travel distances under INBR Topic 3
4Practice calculating stair riser and tread proportions using the standard formula: 2 × Riser + Tread = 63 to 64 cm
5Ensure thorough familiarity with disability accessibility regulations, including maximum 8% pedestrian ramp slopes and 1.50m wheelchair turning circles

Frequently Asked Questions

What is the format of the official Iran Nezam Architecture Design exam?

Clause 6-1 of the official 1405 registration instruction states that all Nezam Mohandesi entry-to-profession exams are four-option multiple choice except architecture-design, which is held as a drawing-based (tarsimi) paper lasting roughly 7 to 8 hours. Candidates are given a site lot with specific zoning parameters, street alignments, and floor area ratios, and must draw complete architectural plans including basement parking, ground floor access, typical residential levels, building sections, and egress details. This is an independent English-language MCQ study adaptation by OpenExamPrep covering the underlying technical codes, dimensions, and regulatory calculations — it is not an official translation and does not simulate the drawing paper.

What are the eligibility requirements for the Nezam Architecture Design exam?

Candidates must hold an accredited degree in Architecture approved by the Ministry of Science, Research and Technology. Eligibility requires a minimum post-graduation practical work period: 3 years for Bachelor's degree (Karshenasi) holders, 2 years for Master's degree (Karshenasi Arshad) holders, or 1 year for Ph.D. (Doctora) holders.

What is the passing score for the Architecture Design exam?

Clause 6-4 of the official 1405 registration instruction sets the pass threshold at 50 out of 100 (50%) for every Nezam Mohandesi discipline and competency, including architecture-design. There is no conditional pass: candidates who miss the threshold simply re-sit in a later round. Evaluation is nonetheless demanding, because serious design errors such as failing to provide required parking stalls, creating unventilated habitable rooms, or violating fire egress rules weigh heavily on the marked drawing.

Is the Architecture Design exam open book?

Yes. Clause 6-2 of the official 1405 registration instruction states that the entry-to-profession exams in all disciplines are held open book (ketab baz); only the Article 27 expert-assessment exam is closed book. Candidates may bring official copies of the National Building Regulations (Mabahes), municipal zoning codes, and drafting guides into the examination hall, alongside manual drafting equipment.

Which National Building Regulations (INBR) are tested in Architecture Design?

The primary tested regulations include Topic 3 (Protection of Buildings Against Fire), Topic 4 (General Building Requirements), Topic 15 (Elevators and Escalators), Topic 18 (Acoustic Insulation and Sound Attenuation), Topic 19 (Energy Conservation in Buildings), and the Urban and Architectural Regulations for Persons with Physical Disabilities.