1Before starting work on a live circuit, the safest first action is to:
A.Isolate the supply and verify it is dead
B.Touch the wires with a bare finger to check
C.Leave the main switch ON for lighting
D.Stand in water for better contact
Explanation: Safe electrical work begins with isolation (switching off and securing the supply) and proving dead with a suitable tester before touch. Working on energised conductors without controls risks shock and arc flash.
2Which personal protective item is most directly used to reduce electric shock risk when handling potentially live equipment?
A.Cotton dust mask only
B.Insulated gloves rated for the voltage
C.Ordinary wet cotton gloves
D.Metal jewellery for better grip
Explanation: Voltage-rated insulating gloves form a barrier between the worker and live parts. They must be dry, undamaged, and suitable for the system voltage, and used with other controls such as isolation when possible.
3Electric shock severity mainly depends on which combination of factors?
A.Only the colour of the cable sheath
B.Current through the body, path, and duration
C.Only the brand of the switchboard
D.Only ambient room temperature
Explanation: Injury from shock is driven by how much current flows through the body, which path it takes (especially heart/brain), and how long contact lasts. Voltage and body resistance affect current via Ohm’s law, but current and path determine harm.
4If a co-worker is receiving a continuous electric shock and is stuck to a live conductor, your first priority is to:
A.Pull them free with bare hands immediately
B.Pour water on them while they remain connected
C.Isolate the supply or separate them with a dry insulating means, then call for help
D.Leave the site without reporting
Explanation: Rescuers must not become second victims. Switch off the supply if possible, or use a dry non-conducting object to break contact, then start first aid/CPR as trained and call emergency services.
5Why should jewellery and metal watches be removed before electrical work?
A.They improve insulation automatically
B.They can short live parts or cause severe burns if current flows through them
C.They are required by all wiring colour codes
D.They increase megger readings
Explanation: Conductive jewellery can bridge terminals or live parts, causing short circuits, arc burns, or concentrating current on skin. Removing metal accessories reduces contact and burn hazards.
6A damaged flexible cord with exposed copper strands should be:
A.Wrapped with ordinary sticky tape and left in service
B.Taken out of service and repaired or replaced by a competent person
C.Painted red so people know it is special
D.Used only for outdoor extension at full load
Explanation: Exposed live conductors are a shock and fire hazard. Remove the equipment from service, tag it defective, and repair or replace the cord correctly—do not rely on temporary adhesive tape as a permanent fix.
7Which practice best reduces fire risk from overloaded wiring?
A.Using multiple high-wattage appliances on one undersized socket adapter chain
B.Matching cable size and protective device rating to the expected load
C.Bypassing fuses with thick copper wire
D.Ignoring warm plugs and smell of burning insulation
Explanation: Overheating occurs when current exceeds the safe capacity of cables or joints. Correct conductor sizing, proper protective devices, and avoiding multi-adapter overloads keep temperature within limits.
8In a workshop, electrical tools with metal bodies should preferably be:
A.Used with broken earth pins if the job is urgent
B.Double-insulated or properly earthed as designed
C.Connected through a wet floor for cooling
D.Operated without any plug
Explanation: Class I tools need a protective earth path; Class II (double-insulated) tools rely on reinforced insulation. Either way, the designed protection must be intact—never defeat the earth pin for convenience.
9Lockout/tagout (or equivalent isolation control) is used mainly to:
A.Speed up production by skipping isolation
B.Prevent unexpected re-energisation while someone is working on equipment
C.Increase voltage during maintenance
D.Replace the need for PPE forever
Explanation: Isolation controls keep the energy source secured so co-workers cannot switch equipment back on during work. Tags communicate who locked it and why; PPE still supports residual risk control.
10Which statement about ladders near overhead lines is correct?
A.Metal ladders are always safest near live lines
B.Keep safe clearance; treat unknown lines as live and use non-conductive ladders when appropriate
C.Touch the line briefly to check if it is dead
D.No clearance is needed if work is quick
Explanation: Approach distance and insulated practices matter near overhead conductors. Metal ladders can conduct; never contact a line to test it. If clearance cannot be guaranteed, de-energise through the utility or stop work.

About the Maharashtra SSC Electrical Technology Pre-Voc/NSQF Exam

Maharashtra SSC Electrical Technology under MSBSHSE is a Class 10 pre-vocational / NSQF skill subject (commonly subject code 92 on modern SSC subject lists; confirm your hall ticket). Core learning themes include electrical safety, circuits, wiring, earthing, protection devices, motors orientation, tools, and employability. Official assessment often combines theory with practical, project, performance, or school-based evidence depending on the subject scheme. About 35% is widely reported as the SSC subject pass floor—confirm the year's notification. This free bank provides English four-option MCQs for knowledge and judgment practice only—pair with official school materials via mahahsscboard.in.

Exam sponsor: Maharashtra State Board of Secondary and Higher Secondary Education (MSBSHSE), Pune. The requirements and fees below concern the certification or admission exam, separate from our free practice resources.

Assessment

Typical SSC pre-vocational / NSQF skill subject pattern: written theory and/or practical/project/performance/internal evidence as per scheme (confirm year's school/board notice). Local bank: English MCQ study adaptation only.

Time Limit

As notified on the year's MSBSHSE SSC timetable for theory where applicable; other components scheduled separately

Passing Score

35%

Exam / Certification Fees

As notified by MSBSHSE and paid through affiliated secondary schools (no single fixed public subject fee for all categories).

Exam sponsor website

Reported exam pass rate: Not published as a fixed subject-wise standing figure for this subject. Exam sponsor website

Fees, eligibility, and exam policies can change. Confirm them with the exam sponsor before applying or paying.

Our practice resources: topics covered

We aim to reflect publicly available exam outlines and topic information in our study resources. Coverage, format, and difficulty may differ from the actual exam, and we cannot guarantee that every detail is accurate or current. Confirm exam requirements, fees, and policies with the official exam sponsor.

~14% of this local bank

Electrical Safety

Lockout, PPE, shock prevention

~14% of this local bank

Basic Circuits

Series/parallel, Ohm/Kirchhoff orientation

~14% of this local bank

Wiring and Installation

Domestic wiring, conduits, colour codes

~14% of this local bank

Earthing and Protection

Earthing, MCB, fuse, ELCB/RCCB concepts

~10% of this local bank

Tools and Instruments

Tester, multimeter, meggers orientation

~10% of this local bank

Machines Orientation

Motors, transformers basics

~12% of this local bank

Maintenance and Fault Finding

Open circuit, short, overload

~12% of this local bank

Employability

Documentation, customer safety advice

Preparing for the Maharashtra SSC Electrical Technology Pre-Voc/NSQF Exam

What You Need to Know

  • Passing score: 35%
  • Assessment: Typical SSC pre-vocational / NSQF skill subject pattern: written theory and/or practical/project/performance/internal evidence as per scheme (confirm year's school/board notice). Local bank: English MCQ study adaptation only.
  • Time limit: As notified on the year's MSBSHSE SSC timetable for theory where applicable; other components scheduled separately
  • Exam / certification fees: As notified by MSBSHSE and paid through affiliated secondary schools (no single fixed public subject fee for all categories). Official sources

Using Our Practice Resources

  • Work through all 100 available questions
  • Review every answer and explanation
  • Track weak areas and revisit them
  • Use our AI tutor for tough concepts

Frequently Asked Questions

How is Maharashtra SSC Electrical Technology officially examined?

It is examined under the Maharashtra Secondary School Certificate as a Class 10 pre-vocational / NSQF skill subject (commonly code 92). Logistics may combine written theory with practical, project, performance, or internal assessment depending on the subject scheme. Candidates generally need about 35% with separate floors as notified. Confirm the year's syllabus and circulars with your school and mahahsscboard.in.

Is this practice bank the same format as the official SSC paper?

No. Official assessment may mix written theory with practical, project, or performance evidence. This bank is an English-language multiple-choice study adaptation for concepts and judgment only—not an official blueprint replica or practical/performance certification substitute.

What subject code is used for Electrical Technology?

Modern Maharashtra SSC subject lists commonly show code 92 for Electrical Technology. Always confirm the code printed on your hall ticket and school registration because board circulars can refine titles or codes.

In which languages is the official assessment offered?

Maharashtra SSC subject materials and papers are commonly available in English and Marathi mediums (and other media as notified for some subjects). This practice bank is an English-language study adaptation, not an official translation of the board paper.

How should I use these free MCQs?

Study your school syllabus first, then drill this bank by category. Read every wrong-option explanation, keep a practical/project journal if required, and re-test weak topics under timed conditions before board week.