All Practice Exams

Free Practice Questions for Odisha CHSE +2 Plumber General (VOC-ITV)

Exam-style questions and explanations by OpenExamPrep.

✓ No registration✓ No credit card
100+ Questions
100% Free

Loading practice questions...

Exam Review

Key Facts: Odisha CHSE +2 Plumber General (VOC-ITV) Exam

VOC-ITV / XI–XII

CHSE lists Plumber General XI and XII and VOC-ITV–Plumber–Plumber General on the official syllabus catalog

CHSE Odisha syllabus page (chseodisha.nic.in/syllabus)

PSC/Q0104

Domain orientation to Plumber–General Qualification Pack Ref. Id. used in Indian school vocational packages

PSSCIVE / school vocational Plumber–General curriculum orientation

Theory + practical

Official assessment combines theory with practical/viva/project evidence—not pure MCQ only

CHSE vocational / VOC-ITV assessment practice; pattern circulars

AHSE package

Examination fee is part of CHSE AHSE enrollment/form-fill-up as notified (not a separate open marketplace job-role fee)

CHSE Odisha AHSE enrollment/form-fill-up fee notifications

100 MCQs

This free local bank is a 100-question English theory-knowledge study adaptation

OpenExamPrep practice bank

Practical not replaced

Workshop skills, journals, viva and project evidence remain mandatory for official success

OpenExamPrep adaptation note; CHSE vocational practical scheme

Free 100-question English MCQ study bank for Odisha CHSE +2 VOC-ITV / Plumber General (XI–XII). Official subject is vocational theory + practical/viva/project under CHSE Odisha (chseodisha.nic.in syllabus; Plumber-General-XI-and-XII.pdf). Fee is part of the AHSE package as notified. Theory-knowledge only—practical/viva not replaced. Domain orientation: PSC/Q0104 Plumber–General.

Sample Odisha CHSE +2 Plumber General (VOC-ITV) Practice Questions

Try these sample questions to review concepts for the Odisha CHSE +2 Plumber General (VOC-ITV) exam. Each question includes a detailed explanation. Start the interactive quiz above for the full 100+ question experience with AI tutoring.

1Under the NSQF-aligned Plumber–General job role used in CHSE VOC-ITV Plumber General, a Plumber–General is primarily responsible for:
A.Installation, major repair, maintenance and servicing of pipes and sanitary fixtures in housing, industrial, commercial and institutional setups
B.Designing multi-storey structural steel frames
C.Selling only ceramic tiles in a retail showroom
D.Only reading water meters for municipal billing
Explanation: The Plumber–General (PSC/Q0104 orientation used in Plumber General XI–XII curricula) installs, repairs, maintains and services pipes and sanitary fixtures across housing, industrial, commercial and institutional work. CHSE Odisha lists VOC-ITV Plumber–Plumber General / Plumber General XI and XII against this trade.
2Which Sector Skill Council is most directly associated with the Plumber–General qualification pack orientation (PSC/Q0104) referenced in Indian school vocational Plumber–General curricula?
A.Water Management and Plumbing Skill Council (WMPSC)
B.Beauty & Wellness Sector Skill Council only
C.Automotive Skills Development Council only
D.Food Industry Capacity & Skill Initiative only
Explanation: Plumber–General learning-outcome curricula for Classes XI–XII are oriented to QP Ref. Id. PSC/Q0104 under the plumbing sector, with WMPSC as the plumbing skill-council reference commonly cited with PSSCIVE materials.
3In a domestic building water-flow system, the sequence that best describes potable water delivery to fixtures is:
A.Source/service → storage or direct supply → distribution pipes → fixture supplies → fixtures
B.Septic tank → manhole → street sewer only
C.Gas service → burner → flue only
D.Drainage stack → soil pipe → roof vent only
Explanation: Potable supply typically moves from the municipal or private source through a service connection, optional storage/overhead arrangements, distribution piping and branch supplies to fixtures. Drainage is a separate waste system.
4Compared with a residential bathroom group, commercial plumbing systems more often require the Plumber–General to plan for:
A.Higher simultaneous demand, more fixture density, larger mains/stacks, and public-use durability
B.Eliminating all traps and vents by code
C.Using only flexible garden hose as the building main
D.Only single-fixture garden taps with no drainage
Explanation: Commercial and institutional work typically means higher fixture counts, peak simultaneous use, larger pipe sizes, and more robust public-use fixtures and supports than a simple dwelling bathroom group.
5A correct workplace behaviour expectation for a Plumber–General trainee on a multi-person site is to:
A.Work as a good listener and team player who follows instructions and coordinates hazard-free workflow with seniors and colleagues
B.Hide defects until handover day
C.Use phones only and never speak to the team
D.Ignore senior instructions if the trainee prefers another method
Explanation: Plumber–General course outcomes emphasise independent competent work plus teamwork: listening, following instructions, coordinating with seniors/colleagues, and maintaining a safe, hazard-free workflow.
6CHSE Odisha’s published syllabus catalog lists Plumber General for Classes XI and XII under which vocational framing?
A.As Plumber General XI and XII / VOC-ITV Plumber–Plumber General (+2 integrated vocational) under the Council of Higher Secondary Education, Odisha
B.Only as a postgraduate civil engineering research paper
C.Only as a Class V drawing hobby club
D.Only as a pure theoretical philosophy elective with no skill component
Explanation: On chseodisha.nic.in/syllabus, Plumber General XI and XII and VOC-ITV–Plumber–Plumber General appear as +2 vocational / integrated vocational entries under CHSE Odisha.
7In Indian domestic plumbing practice, GI pipe most commonly means:
A.Galvanised iron (zinc-coated steel) pipe
B.Green insulated electrical conduit only
C.Graphite-lined lead pipe only
D.Glass-insulated copper only
Explanation: GI stands for galvanised iron: mild-steel pipe with a zinc coating that slows rust. It is widely used for cold-water and some outdoor service lines where mechanical strength is needed.
8uPVC (unplasticised PVC) cold-water pressure pipe is generally preferred over GI when the priority is:
A.Corrosion resistance and lower weight for cold potable distribution within material temperature/pressure ratings
B.Serving as a high-temperature steam main above 200 °C
C.Replacing structural rebar in columns
D.Maximum electrical conductivity for earthing
Explanation: uPVC is light, corrosion-resistant and common for cold-water distribution within rated pressure and temperature limits. It is not a steam main and is not structural rebar.
9CPVC is commonly selected for domestic hot-and-cold potable lines mainly because it:
A.Is a pure metal alloy that cannot use solvent cement
B.Must never be used for any potable water
C.Is only suitable for underground gas transmission at high pressure
D.Has better temperature resistance for hot water than ordinary cold-water PVC within manufacturer ratings
Explanation: Chlorinated PVC (CPVC) is formulated for higher service temperatures than ordinary PVC, making it a common choice for hot-and-cold potable distribution when installed per manufacturer ratings and jointing rules.
10Which fitting primarily changes the direction of a pipe run (for example 90° or 45°)?
A.Water meter only
B.Roof flashing only
C.Gate valve only
D.Elbow (or bend)
Explanation: Elbows and bends change direction. Valves control flow; meters measure; flashing weathers roof penetrations.

About the Odisha CHSE +2 Plumber General (VOC-ITV) Exam

Odisha CHSE Higher Secondary Plumber–General prepares +2 students for the Plumber–General job role under the Council of Higher Secondary Education, Odisha. The Council syllabus catalog lists Plumber General XI and XII and VOC-ITV–Plumber–Plumber General as +2 vocational / integrated vocational offerings. Domain content covers pipes and fittings, tools, measurement and basic estimation, water supply and drainage installation, sanitary fixtures, valves, jointing/sealing, safety, and troubleshooting—aligned with the PSC/Q0104 Plumber–General orientation used in Indian school vocational packages. Assessment is theory-plus-practical (with viva/project evidence as notified), with fees collected through the AHSE enrollment package rather than a separate public marketplace price. This free English MCQ bank builds theory fluency for pipes, water, drainage, fixtures and safety—it is not an official-format simulation and does not replace workshop skills or viva.

Exam sponsor: CHSE Odisha. The requirements and fees below concern the certification or admission exam, separate from our free practice resources.

Assessment

CHSE Odisha lists Plumber General for Classes XI and XII and VOC-ITV–Plumber–Plumber General as a +2 integrated vocational job-role subject on chseodisha.nic.in/syllabus. Domain learning aligns with the national Plumber–General school vocational curriculum orientation (PSC/Q0104): introduction to the plumbing sector and job role; basics of plumbing (symbols/terminology, BIS/ISI ideas, accurate measurement and calculation, pipes/fittings/supports/sealants, tools and lifting aids, water properties/pressure/flow); preparation using drawings, layouts and material take-off; installation of water supply piping (layouts, supports, jointing, alignment, testing); installation of drainage systems (soil/waste/vent, traps, chambers); installation of sanitary fixtures; troubleshooting and maintenance (including blockage clearing and corrosion protection); health and safety; teamwork; and resource-efficient work. Employability skill units run alongside domain units. Official success requires practical/workshop and viva/project evidence—this free 100-question bank is an English MCQ study adaptation of theory knowledge only.

Time Limit

Official theory and practical durations follow the CHSE Odisha AHSE / vocational timetable and subject scheme for the sitting (confirm current notice). This practice bank is untimed.

Passing Score

Published CHSE 2026 passing marks require about 30% in both theory and practical components (e.g., 12/40 theory and 18/60 practical for vocational trade subjects). Confirm the current AHSE / VOC-ITV circular for your registration year and subject code.

Exam / Certification Fees

Included in the CHSE Odisha AHSE enrollment / form-fill-up fee package as notified for the sitting, plus any practical/project evaluation fees; exact rupees vary by year (illustrative AHSE 2025 form-fill-up subtotal Rs.520)—see official notifications on chseodisha.nic.in.

Exam sponsor website

Our practice resources: topics covered

We aim to reflect publicly available exam outlines and topic information in our study resources. Coverage, format, and difficulty may differ from the actual exam, and we cannot guarantee that every detail is accurate or current. Confirm exam requirements, fees, and policies with the official exam sponsor.

Study emphasis ~6%

Plumbing Industry & Job Role

Job-role scope, sector context, domestic vs commercial systems, CHSE VOC-ITV framing.

Study emphasis ~14%

Pipes & Fittings

GI/uPVC/CPVC/copper/PPR materials; elbows, tees, reducers, unions, couplings, caps.

Study emphasis ~8%

Tools & Equipment

Wrenches, vices, cutters, levels, reamers, measuring tools, lifting aids.

Study emphasis ~8%

Measurement & Basic Estimation

c/c and end-to-end measure, thread make-up, take-off, simple cost and pressure–head ideas.

Study emphasis ~14%

Water Supply Systems

Direct/indirect supply, tanks, concealed/buried piping, supports, testing, hot/cold feeds.

Study emphasis ~12%

Drainage Systems

Traps, soil/waste/vent, gradient, chambers, soak pits, water-carriage concepts.

Study emphasis ~10%

Plumbing Fixtures

Basins, WCs, sinks, urinals, baths/showers, sensor fittings, layout and standards.

Study emphasis ~8%

Valves & Controls

Gate, globe, ball, check, PRV, float and TMV isolation/control devices.

Study emphasis ~8%

Sealing & Jointing

PTFE, solvent cement, putty, solder, compression, rubber-ring and flange seals.

Study emphasis ~12%

Safety & Troubleshooting

PPE, isolation, fire/chemical hazards, trap/vent faults, blockages, corrosion, leaks.

Preparing for the Odisha CHSE +2 Plumber General (VOC-ITV) Exam

What You Need to Know

  • Passing score: Published CHSE 2026 passing marks require about 30% in both theory and practical components (e.g., 12/40 theory and 18/60 practical for vocational trade subjects). Confirm the current AHSE / VOC-ITV circular for your registration year and subject code.
  • Assessment: CHSE Odisha lists Plumber General for Classes XI and XII and VOC-ITV–Plumber–Plumber General as a +2 integrated vocational job-role subject on chseodisha.nic.in/syllabus. Domain learning aligns with the national Plumber–General school vocational curriculum orientation (PSC/Q0104): introduction to the plumbing sector and job role; basics of plumbing (symbols/terminology, BIS/ISI ideas, accurate measurement and calculation, pipes/fittings/supports/sealants, tools and lifting aids, water properties/pressure/flow); preparation using drawings, layouts and material take-off; installation of water supply piping (layouts, supports, jointing, alignment, testing); installation of drainage systems (soil/waste/vent, traps, chambers); installation of sanitary fixtures; troubleshooting and maintenance (including blockage clearing and corrosion protection); health and safety; teamwork; and resource-efficient work. Employability skill units run alongside domain units. Official success requires practical/workshop and viva/project evidence—this free 100-question bank is an English MCQ study adaptation of theory knowledge only.
  • Time limit: Official theory and practical durations follow the CHSE Odisha AHSE / vocational timetable and subject scheme for the sitting (confirm current notice). This practice bank is untimed.
  • Exam / certification fees: Included in the CHSE Odisha AHSE enrollment / form-fill-up fee package as notified for the sitting, plus any practical/project evaluation fees; exact rupees vary by year (illustrative AHSE 2025 form-fill-up subtotal Rs.520)—see official notifications on chseodisha.nic.in. Official sources

Using Our Practice Resources

  • Work through all 100 available questions
  • Review every answer and explanation
  • Track weak areas and revisit them
  • Use our AI tutor for tough concepts

Odisha CHSE +2 Plumber General (VOC-ITV): Suggested Study Strategy

1Build a material card for GI, uPVC, CPVC, copper and PPR: typical uses, jointing method, and temperature/pressure cautions.
2Drill fitting identification (elbow, tee, reducer, union, coupling, cap) with one real installation example each.
3Practise center-to-center vs end-to-end measure and thread make-up on scrap pipe before exam week.
4Sketch a simple bathroom: cold/hot supplies, traps, soil/waste branches and a vent path—label each part.
5Memorise isolation vs check vs PRV vs float valve purposes with one fault each prevents.
6For jointing, list correct steps for PTFE threads, PVC solvent cement and copper solder—and the usual failure mode of each.
7Safety: rehearse isolation/depressurise before opening lines, PPE for cutting/chemicals, and never cross-connect waste to potable.
8Complete practical journal tasks (cutting/threading, joint samples, fixture fixings, test pressure logs)—MCQs do not replace them.
9Read Plumber-General-XI-and-XII.pdf and the current AHSE fee/timetable notices on chseodisha.nic.in before exam week.

Frequently Asked Questions

Is the official CHSE Plumber General exam only multiple choice?

No. Plumber General / VOC-ITV Plumber–General is a vocational job-role subject with theory plus practical, viva and project/portfolio evidence as notified for the year. Theory may include MCQ and/or short/descriptive items under the current pattern circular. This bank is an English theory-knowledge MCQ study adaptation only—it does not replace practical or occupational assessment.

What syllabus does this practice bank follow?

It targets CHSE Odisha Plumber General XI and XII / VOC-ITV–Plumber–Plumber General as listed on chseodisha.nic.in/syllabus, with domain topics oriented to the national Plumber–General school vocational curriculum (PSC/Q0104): pipes/fittings, tools, measurement, water supply, drainage, fixtures, troubleshooting, safety and related workplace skills.

What topics should I prioritise for theory?

Prioritise pipe materials and fittings, jointing/sealing methods, water-supply layouts and testing, drainage traps/vents/gradients, fixture installation sequences, common valves, basic measurement/estimation, and health & safety including isolation and PPE.

What is the examination fee?

Plumber General is examined as part of the Higher Secondary vocational / VOC-ITV AHSE package. Fees are collected through CHSE enrollment / form fill-up as notified (illustrative AHSE 2025 form-fill-up subtotal Rs.520, with related certificate heads and practical/project fees adding further charges). Check the current circular on chseodisha.nic.in rather than unofficial fixed rupee quotes.

What are typical pass floors?

Published CHSE 2026 passing marks require about 30% in both theory and practical components (e.g., 12/40 theory and 18/60 practical for vocational trade subjects). Always confirm the circular that applies to your registration year and subject.

Why use MCQs if practicals matter so much?

MCQs quickly check theory facts on materials, joints, layouts, traps, valves and safety. Official success still depends on workshop skills, journals, viva and project evidence—practise those with your school alongside this free theory bank.