All Practice Exams

Free Practice Questions for F-Gas Category I

Exam-style questions and explanations by OpenExamPrep.

✓ No registration✓ No credit card
106+ Questions
100% Free

Loading practice questions...

Same family resources

Explore More Ireland F-Gas Refrigerant Certification

Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.

Exam Review

Key Facts: F-Gas Category I Exam

100

Practice Questions

OpenExamPrep

NFQ Level 5

QQI Special Purpose Award

QQI

Certificate A1

New EU Certificate (replaces Category I)

Regulation (EU) 2024/2215

Any size

Category I Charge Scope

EPA Ireland

5 t CO2e

Leak-Check Threshold

Regulation (EU) 2024/573

S.I. 404/2022

Irish F-Gas Regulations

Irish Statute Book

The QQI Level 5 F-Gas Category I certificate is Ireland's full-scope qualification for handling fluorinated greenhouse gases on stationary refrigeration, air-conditioning and heat-pump equipment of any size: installation, servicing, repair, decommissioning, leak checking and recovery without charge-size limits. QQI-validated programmes assess a theory test and a practical skills demonstration, and both must be passed. Since 2024 the EU rules are Regulation (EU) 2024/573, which replaced Regulation (EU) No 517/2014, and Implementing Regulation (EU) 2024/2215, which replaced Category I with Certificate A1; existing Category I holders keep using their certificates only if they update their knowledge and skills to the A1 level (Article 10(a)). The EPA enforces the rules and F-Gas Registration Ltd issues company certificates. This free prep includes 100 research-based practice questions with explanations and an AI tutor.

Sample F-Gas Category I Practice Questions

Try these sample questions to review concepts for the F-Gas Category I exam. Each question includes a detailed explanation. Start the interactive quiz above for the full 106+ question experience with AI tutoring.

1What was the scope of the Category I personnel certificate under Commission Implementing Regulation (EU) 2015/2067, the scheme behind Ireland's existing Category I certificates?
A.All installation, maintenance, servicing, repair, decommissioning, leak checking and recovery activities on stationary refrigeration and air-conditioning equipment of any charge size
B.Leak checking only on hermetically sealed systems under 3 kg without breaking the circuit
C.Recovery of refrigerant from small hermetically sealed systems only
D.Installation of split air-conditioning units under 6 kg charge only
Explanation: Category I was the full-scope certificate under Implementing Regulation (EU) 2015/2067 (Article 3(2)(a)): all regulated F-gas activities on stationary refrigeration, air-conditioning and heat pump equipment, whatever the charge. Regulation (EU) 2024/2215 repealed Implementing Regulation (EU) 2015/2067 in 2024; Certificate A1 now covers all activities on any charge (Article 3(2)(a)), and existing Category I holders may keep using their certificates only if they update their knowledge and skills to the A1 level (Article 10(a)).
2Which Irish statutory instrument, signed in July 2022, designates the EPA as competent authority and creates offences for the EU F-gas rules, replacing S.I. No. 658 of 2016?
A.S.I. No. 404 of 2022 (European Union (Fluorinated Greenhouse Gases) Regulations 2022)
B.S.I. No. 658 of 2016, unchanged since 2016
C.The Environmental Protection Agency Act 1992 on its own
D.None: the EU Regulation needs no national enforcement provisions
Explanation: S.I. No. 404 of 2022, the European Union (Fluorinated Greenhouse Gases) Regulations 2022 (signed 28 July 2022), designates the EPA as competent authority, creates offences such as carrying out certified work without the required certificate, and revoked S.I. No. 658 of 2016 (Regulation 25). It was made to implement Regulation (EU) No 517/2014; the EU Regulation now in force is Regulation (EU) 2024/573, which repealed 517/2014 from 11 March 2024.
3In Ireland, who is the competent authority responsible for enforcing F-Gas Regulation requirements on stationary equipment?
A.The Environmental Protection Agency (EPA)
B.The Health and Safety Authority (HSA) only
C.F-Gas Registration Ltd
D.Quality and Qualifications Ireland (QQI)
Explanation: The EPA enforces the F-Gas Regulation (EU) 2024/573 in Ireland and is designated competent authority by S.I. No. 404 of 2022. F-Gas Registration Ltd issues company certificates, and QQI is the certification body for personnel qualifications.
4Which QQI award has been Ireland's personnel qualification for Category I F-gas work on large refrigeration, air-conditioning and heat pump systems?
A.QQI Level 5 Special Purpose Certificate in F-gas Handling in Large RACHPT&T Systems Category I
B.QQI Level 3 Certificate in Plumbing and Heating
C.A City & Guilds 2079 Level 2 certificate alone without Irish registration
D.An EPA environmental officer licence
Explanation: QQI's award standard (April 2020) for the Level 5 Special Purpose Certificate in F-gas Handling in Large RACHPT&T Systems Category I requires a theory test and a skills demonstration meeting Annex 1, Category I, of Implementing Regulation (EU) 2015/2067, and EPA Ireland names QQI as the personnel certification body. Regulation (EU) 2024/2215 repealed Implementing Regulation (EU) 2015/2067 in 2024; Category I holders keep using their certificates only if they update to the Certificate A1 level (Article 10(a)).
5From 1 January 2021, which statement about UK F-Gas personnel certificates is correct for work in Ireland?
A.UK-issued F-Gas personnel certificates are no longer recognised for work in Ireland; an Irish (QQI-based) or other EU-issued certificate is required
B.UK certificates remain fully equivalent if the technician also holds a Safe Pass card
C.UK certificates are valid only for systems under 3 kg charge
D.UK certificates are recognised provided the company is registered in Northern Ireland
Explanation: EPA Ireland states that from 1 January 2021 UK F-gas certification body awards are no longer recognised in the EU. Technicians working in Ireland need a valid Irish certificate, obtained through QQI-approved training, or a certificate issued in another EU Member State.
6What is the primary role of F-Gas Registration Ltd in the Irish F-Gas regime?
A.To issue F-gas company certificates and keep the public register of certified companies
B.To set HFC import quotas for the Irish market
C.To conduct mandatory EPA leak inspections on all RAC plant
D.To approve new refrigerant blends for sale in the EU
Explanation: EPA Ireland states that F-Gas Registration Ltd is the certification company established in Ireland to issue company certificates, and that it maintains a public register of certified companies. Personnel qualifications come through QQI-approved training.
7Commission Implementing Regulation (EU) 2024/2215 replaced the Category I–IV certificates of Regulation (EU) 2015/2067. On which equipment may a technician holding Certificate A2, the certificate that replaces Category II, carry out installation, servicing, repair, decommissioning and recovery?
A.Equipment containing less than 3 kg of fluorinated refrigerant, or less than 6 kg if the system is hermetically sealed and labelled as such
B.Any stationary system regardless of charge size
C.Mobile air-conditioning in road vehicles only
D.Equipment of 500 tonnes CO2 equivalent or more only
Explanation: Article 3(2)(b) of Commission Implementing Regulation (EU) 2024/2215 gives Certificate A2 holders all the certified activities for F-gases and hydrocarbons, limited to equipment with a charge of less than 3 kg, or less than 6 kg for labelled hermetically sealed systems. Under Article 10(a), holders of an old Category II certificate may keep using it only if they update their knowledge and skills to the A2 level.
8What activities did the Category III certificate under Implementing Regulation (EU) 2015/2067 permit?
A.Recovery of fluorinated refrigerant from small systems only
B.Full installation and commissioning of commercial chillers
C.Leak checking without breaking the refrigerant circuit only
D.Design of VRF systems and load calculations only
Explanation: Category III is limited to recovery operations on small equipment. It does not authorise charging, installation, or leak checking that involves breaking into the circuit on larger systems. Under Regulation (EU) 2024/2215, Certificate D replaces it (recovery from equipment under 3 kg, or 6 kg if labelled hermetically sealed), and Category III holders keep using their certificates only if they update to the D level (Article 10(b)).
9Under a Category IV certificate (Implementing Regulation (EU) 2015/2067; now Certificate E under Regulation (EU) 2024/2215), a technician may perform which activity?
A.Leak checking without breaking the refrigerant circuit
B.Recovery and recycling of refrigerant from any system size
C.Brazing new pipework on a split system during first fix installation
D.Pressure strength testing with nitrogen on a new circuit
Explanation: Category IV covered only leak checks that do not entail breaking into the refrigeration circuit, and Certificate E under Article 3(2)(f) of Regulation (EU) 2024/2215 covers the same. Category IV holders keep using their certificates only if they update to the E level (Article 10(c)). Any work opening the circuit needs a broader certificate.
10Which operator duties under the EU F-Gas Regulation (EU) 2024/573 must the owner of F-gas equipment in Ireland meet?
A.Prevent deliberate release of F-gases, use certified personnel, maintain leak-check records and ensure proper recovery at end of life
B.Replace all HFC systems with CO2 within two years of installation
C.Publish annual refrigerant inventories on the company website
D.Employ an EPA inspector on site for every service visit
Explanation: Operators (owners/controllers of equipment) must prevent venting, use certified companies/personnel for regulated work, comply with leak-check schedules, label equipment and keep records of gas quantities and service activities.

About the F-Gas Category I Exam

The QQI Level 5 Special Purpose Certificate in F-gas Handling in Large RACHPT&T Systems Category I is Ireland's full-scope fluorinated-gas handling qualification for stationary refrigeration, air-conditioning and heat-pump equipment of any charge size and the refrigeration units of refrigerated trucks and trailers. QQI's award standard (April 2020) builds it on Annex 1, Category I, of Implementing Regulation (EU) 2015/2067. Since 2024 the EU rules are Regulation (EU) 2024/573, which replaced Regulation (EU) No 517/2014, and Implementing Regulation (EU) 2024/2215, which replaced Category I with Certificate A1; existing Category I holders keep using their certificates only if they update their knowledge and skills to the A1 level (Article 10(a)).

Exam sponsor: Quality and Qualifications Ireland (QQI), with programmes delivered by approved training providers; F-Gas Registration Ltd issues company certificates. The requirements and fees below concern the certification or admission exam, separate from our free practice resources.

Assessment

Theory examination plus skills demonstration / practical assessment on a working vapour-compression refrigeration system with TEV and liquid receiver. Both must be passed for the QQI Level 5 Special Purpose Award. This practice bank is 100 selected-response items.

Time Limit

Set by the training provider (QQI's award standard sets no exam duration)

Passing Score

Pass both the theory examination and skills demonstration (pass criteria set by the QQI-validated programme provider)

Exam / Certification Fees

Set by each training provider

Exam sponsor website

Fees, eligibility, and exam policies can change. Confirm them with the exam sponsor before applying or paying.

Our practice resources: topics covered

We aim to reflect publicly available exam outlines and topic information in our study resources. Coverage, format, and difficulty may differ from the actual exam, and we cannot guarantee that every detail is accurate or current. Confirm exam requirements, fees, and policies with the official exam sponsor.

Not published

F-Gas Regulation & Certification

EU 2024/573 (which replaced 517/2014), S.I. No. 404 of 2022, Categories I–IV and certificates A1–E, QQI award, F-Gas Registration Ltd, operator duties, labelling and records

Not published

Environmental Impact & Refrigerants

GWP/ODP, CO2-equivalent calculation, refrigerant types, HFC phase-down, natural and low-GWP alternatives

Not published

Leak Checking & Detection

5/50/500 tonne CO2e thresholds, check frequencies, direct/indirect methods, fixed detection and repair verification

Not published

Recovery, Charging & Records

Venting ban, recovery cylinders, recycling vs reclamation, cross-contamination and commissioning records

Not published

Refrigeration Cycle & Thermodynamics

Vapour-compression cycle, superheat/subcooling, latent heat, p-h diagrams and COP

Not published

System Components & Servicing

Compressors, condensers, evaporators, TEV, filter driers, sight glasses, receivers, controls and fault finding

Not published

Installation, Piping & Pressure Testing

OFN-purged brazing, pressure strength/tightness testing, evacuation and leak-tight pipework

Preparing for the F-Gas Category I Exam

What You Need to Know

  • Passing score: Pass both the theory examination and skills demonstration (pass criteria set by the QQI-validated programme provider)
  • Assessment: Theory examination plus skills demonstration / practical assessment on a working vapour-compression refrigeration system with TEV and liquid receiver. Both must be passed for the QQI Level 5 Special Purpose Award. This practice bank is 100 selected-response items.
  • Time limit: Set by the training provider (QQI's award standard sets no exam duration)
  • Exam / certification fees: Set by each training provider Official sources

Using Our Practice Resources

  • Work through all 106 available questions
  • Review every answer and explanation
  • Track weak areas and revisit them
  • Use our AI tutor for tough concepts

F-Gas Category I: Suggested Study Strategy

1Memorise the four certification categories and their charge-size limits: Category I (any size), II (<3 kg or <6 kg sealed), III (recovery only, small), IV (leak check without breaking circuit), now Certificates A1, A2, D and E under Regulation (EU) 2024/2215
2Know the CO2-equivalent formula: charge (kg) × GWP ÷ 1000, and the leak-check thresholds at 5, 50 and 500 tonnes CO2e
3Learn the leak-check frequencies with and without fixed detection systems for each charge band
4Understand the venting ban: all F-gas must be recovered before opening a circuit or disposing of equipment
5Practise OFN purging during brazing, pressure strength testing and deep evacuation before charging
6Complete all 100 practice questions and review every miss with the AI tutor before your theory exam

Frequently Asked Questions

What activities does F-Gas Category I cover in Ireland?

Category I is the highest level of personal F-gas certification under Implementing Regulation (EU) 2015/2067. Holders may carry out installation, maintenance, servicing, repair, decommissioning, leak checking and refrigerant recovery on stationary refrigeration, air-conditioning and heat-pump equipment of any charge size, and on refrigeration units of refrigerated trucks and trailers. Since 2024, Certificate A1 under Regulation (EU) 2024/2215 covers the same full scope, and Category I holders keep using their certificates only if they update to the A1 level.

How is F-Gas Category I different from Category II?

Category II permits the same activities but only on equipment containing less than 3 kg of F-gas (or less than 6 kg if hermetically sealed and labelled). Category II leak checking must not entail breaking into the refrigerant circuit. Category I has no charge-size restriction and covers intrusive leak checking on any system.

Who awards the F-Gas Category I certificate in Ireland?

Training programmes are validated by Quality and Qualifications Ireland (QQI) and delivered by approved providers. On successful completion you receive the QQI Level 5 Special Purpose Certificate in F-gas Handling in Large RACHPT&T Systems Category I. EPA Ireland names QQI as the personnel certification body; F-Gas Registration Ltd issues company certificates.

What are the prerequisites for the Category I course?

QQI's award standard for Category I does not set entry requirements; check the entry criteria of the training provider.

When must equipment be leak-checked under EU 2024/573?

Under Article 5 of Regulation (EU) 2024/573, periodic leak checks begin at 5 tonnes CO2 equivalent. Equipment with 5 to under 50 t CO2e is checked at least every 12 months (24 months with a leak detection system), 50 to under 500 t every 6 months (12 months with one), and 500 t or more every 3 months (6 months with the leak detection system that Article 6 requires).

Is this free F-Gas Category I practice as good as paid prep?

Our 100 practice questions cover the Annex 1 knowledge areas in QQI's Category I award standard and the current Irish and EU F-gas rules, with a teaching explanation for every answer plus free daily AI tutor interactions. All content is free forever and updated for 2026.