Free Practice Questions for F-Gas Category I
Exam-style questions and explanations by OpenExamPrep.
Loading practice questions...
Explore More Ireland F-Gas Refrigerant Certification
Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.
Key Facts: F-Gas Category I Exam
100
Practice Questions
OpenExamPrep
NFQ Level 5
QQI Special Purpose Award
QQI
Certificate A1
New EU Certificate (replaces Category I)
Regulation (EU) 2024/2215
Any size
Category I Charge Scope
EPA Ireland
5 t CO2e
Leak-Check Threshold
Regulation (EU) 2024/573
S.I. 404/2022
Irish F-Gas Regulations
Irish Statute Book
The QQI Level 5 F-Gas Category I certificate is Ireland's full-scope qualification for handling fluorinated greenhouse gases on stationary refrigeration, air-conditioning and heat-pump equipment of any size: installation, servicing, repair, decommissioning, leak checking and recovery without charge-size limits. QQI-validated programmes assess a theory test and a practical skills demonstration, and both must be passed. Since 2024 the EU rules are Regulation (EU) 2024/573, which replaced Regulation (EU) No 517/2014, and Implementing Regulation (EU) 2024/2215, which replaced Category I with Certificate A1; existing Category I holders keep using their certificates only if they update their knowledge and skills to the A1 level (Article 10(a)). The EPA enforces the rules and F-Gas Registration Ltd issues company certificates. This free prep includes 100 research-based practice questions with explanations and an AI tutor.
Sample F-Gas Category I Practice Questions
Try these sample questions to review concepts for the F-Gas Category I exam. Each question includes a detailed explanation. Start the interactive quiz above for the full 106+ question experience with AI tutoring.
1What was the scope of the Category I personnel certificate under Commission Implementing Regulation (EU) 2015/2067, the scheme behind Ireland's existing Category I certificates?
2Which Irish statutory instrument, signed in July 2022, designates the EPA as competent authority and creates offences for the EU F-gas rules, replacing S.I. No. 658 of 2016?
3In Ireland, who is the competent authority responsible for enforcing F-Gas Regulation requirements on stationary equipment?
4Which QQI award has been Ireland's personnel qualification for Category I F-gas work on large refrigeration, air-conditioning and heat pump systems?
5From 1 January 2021, which statement about UK F-Gas personnel certificates is correct for work in Ireland?
6What is the primary role of F-Gas Registration Ltd in the Irish F-Gas regime?
7Commission Implementing Regulation (EU) 2024/2215 replaced the Category I–IV certificates of Regulation (EU) 2015/2067. On which equipment may a technician holding Certificate A2, the certificate that replaces Category II, carry out installation, servicing, repair, decommissioning and recovery?
8What activities did the Category III certificate under Implementing Regulation (EU) 2015/2067 permit?
9Under a Category IV certificate (Implementing Regulation (EU) 2015/2067; now Certificate E under Regulation (EU) 2024/2215), a technician may perform which activity?
10Which operator duties under the EU F-Gas Regulation (EU) 2024/573 must the owner of F-gas equipment in Ireland meet?
About the F-Gas Category I Exam
The QQI Level 5 Special Purpose Certificate in F-gas Handling in Large RACHPT&T Systems Category I is Ireland's full-scope fluorinated-gas handling qualification for stationary refrigeration, air-conditioning and heat-pump equipment of any charge size and the refrigeration units of refrigerated trucks and trailers. QQI's award standard (April 2020) builds it on Annex 1, Category I, of Implementing Regulation (EU) 2015/2067. Since 2024 the EU rules are Regulation (EU) 2024/573, which replaced Regulation (EU) No 517/2014, and Implementing Regulation (EU) 2024/2215, which replaced Category I with Certificate A1; existing Category I holders keep using their certificates only if they update their knowledge and skills to the A1 level (Article 10(a)).
Exam sponsor: Quality and Qualifications Ireland (QQI), with programmes delivered by approved training providers; F-Gas Registration Ltd issues company certificates. The requirements and fees below concern the certification or admission exam, separate from our free practice resources.
Assessment
Theory examination plus skills demonstration / practical assessment on a working vapour-compression refrigeration system with TEV and liquid receiver. Both must be passed for the QQI Level 5 Special Purpose Award. This practice bank is 100 selected-response items.
Time Limit
Set by the training provider (QQI's award standard sets no exam duration)
Passing Score
Pass both the theory examination and skills demonstration (pass criteria set by the QQI-validated programme provider)
Fees, eligibility, and exam policies can change. Confirm them with the exam sponsor before applying or paying.
Our practice resources: topics covered
We aim to reflect publicly available exam outlines and topic information in our study resources. Coverage, format, and difficulty may differ from the actual exam, and we cannot guarantee that every detail is accurate or current. Confirm exam requirements, fees, and policies with the official exam sponsor.
F-Gas Regulation & Certification
EU 2024/573 (which replaced 517/2014), S.I. No. 404 of 2022, Categories I–IV and certificates A1–E, QQI award, F-Gas Registration Ltd, operator duties, labelling and records
Environmental Impact & Refrigerants
GWP/ODP, CO2-equivalent calculation, refrigerant types, HFC phase-down, natural and low-GWP alternatives
Leak Checking & Detection
5/50/500 tonne CO2e thresholds, check frequencies, direct/indirect methods, fixed detection and repair verification
Recovery, Charging & Records
Venting ban, recovery cylinders, recycling vs reclamation, cross-contamination and commissioning records
Refrigeration Cycle & Thermodynamics
Vapour-compression cycle, superheat/subcooling, latent heat, p-h diagrams and COP
System Components & Servicing
Compressors, condensers, evaporators, TEV, filter driers, sight glasses, receivers, controls and fault finding
Installation, Piping & Pressure Testing
OFN-purged brazing, pressure strength/tightness testing, evacuation and leak-tight pipework
Preparing for the F-Gas Category I Exam
What You Need to Know
- Passing score: Pass both the theory examination and skills demonstration (pass criteria set by the QQI-validated programme provider)
- Assessment: Theory examination plus skills demonstration / practical assessment on a working vapour-compression refrigeration system with TEV and liquid receiver. Both must be passed for the QQI Level 5 Special Purpose Award. This practice bank is 100 selected-response items.
- Time limit: Set by the training provider (QQI's award standard sets no exam duration)
- Exam / certification fees: Set by each training provider Official sources
Using Our Practice Resources
- Work through all 106 available questions
- Review every answer and explanation
- Track weak areas and revisit them
- Use our AI tutor for tough concepts
F-Gas Category I: Suggested Study Strategy
Frequently Asked Questions
What activities does F-Gas Category I cover in Ireland?
Category I is the highest level of personal F-gas certification under Implementing Regulation (EU) 2015/2067. Holders may carry out installation, maintenance, servicing, repair, decommissioning, leak checking and refrigerant recovery on stationary refrigeration, air-conditioning and heat-pump equipment of any charge size, and on refrigeration units of refrigerated trucks and trailers. Since 2024, Certificate A1 under Regulation (EU) 2024/2215 covers the same full scope, and Category I holders keep using their certificates only if they update to the A1 level.
How is F-Gas Category I different from Category II?
Category II permits the same activities but only on equipment containing less than 3 kg of F-gas (or less than 6 kg if hermetically sealed and labelled). Category II leak checking must not entail breaking into the refrigerant circuit. Category I has no charge-size restriction and covers intrusive leak checking on any system.
Who awards the F-Gas Category I certificate in Ireland?
Training programmes are validated by Quality and Qualifications Ireland (QQI) and delivered by approved providers. On successful completion you receive the QQI Level 5 Special Purpose Certificate in F-gas Handling in Large RACHPT&T Systems Category I. EPA Ireland names QQI as the personnel certification body; F-Gas Registration Ltd issues company certificates.
What are the prerequisites for the Category I course?
QQI's award standard for Category I does not set entry requirements; check the entry criteria of the training provider.
When must equipment be leak-checked under EU 2024/573?
Under Article 5 of Regulation (EU) 2024/573, periodic leak checks begin at 5 tonnes CO2 equivalent. Equipment with 5 to under 50 t CO2e is checked at least every 12 months (24 months with a leak detection system), 50 to under 500 t every 6 months (12 months with one), and 500 t or more every 3 months (6 months with the leak detection system that Article 6 requires).
Is this free F-Gas Category I practice as good as paid prep?
Our 100 practice questions cover the Annex 1 knowledge areas in QQI's Category I award standard and the current Irish and EU F-gas rules, with a teaching explanation for every answer plus free daily AI tutor interactions. All content is free forever and updated for 2026.