Career upgrade: Learn practical AI skills for better jobs and higher pay.
Level up
All Practice Exams

100+ Free IBM Sterling B2B Integrator (C8060-218) Practice Questions

Pass your IBM Certified Solution Implementer - Sterling B2B Integrator V5.2 (C8060-218) exam on the first try — instant access, no signup required.

✓ No registration✓ No credit card✓ No hidden fees✓ Start practicing immediately
IBM does not publicly report pass rates Pass Rate
100+ Questions
100% Free
1 / 100
Question 1
Score: 0/0

Which scheduled process rebuilds the search-able indexes used by document tracking and the BP monitor?

A
B
C
D
to track
2026 Statistics

Key Facts: IBM Sterling B2B Integrator (C8060-218) Exam

$200

Exam Fee (USD)

IBM C8060-218 listing

~50-60

Questions (approx)

IBM does not publish exact count

~75-90 min

Time Limit (approx)

IBM-typical exam format

~63%

Passing Score (approx)

IBM-typical scoring

V5.2

Product Version

No V6 admin exam exists yet

Pearson VUE

Test Delivery

In-person or online proctored

The IBM Certified Solution Implementer - Sterling B2B Integrator V5.2 (C8060-218) is the active IBM exam for Sterling B2B Integrator implementer skills, costing $200 USD through Pearson VUE. The exam is approximately 50-60 multiple-choice questions in 75-90 minutes with an approximately 63% passing score (IBM does not publish exact figures). It validates skills across installation/configuration, business process development with GPM/BPML, integration via AS2/SFTP/FTP/OFTP/MLLP, advanced trading partner profiles, administration, and troubleshooting. Note that this is a V5.2 credential — the current product line is V6.x, but IBM has not yet released a V6 administrator/implementer exam, so C8060-218 remains the relevant certification for Sterling B2B Integrator implementer roles in 2026.

Sample IBM Sterling B2B Integrator (C8060-218) Practice Questions

Try these sample questions to test your IBM Sterling B2B Integrator (C8060-218) exam readiness. Each question includes a detailed explanation. Start the interactive quiz above for the full 100+ question experience with AI tutoring.

1Which Sterling B2B Integrator V5.2.6 component is the main JVM that hosts adapters, services, and the workflow engine by default?
A.Perimeter Server (PS)
B.OpsServer
C.Application Server Independent (ASI)
D.Adapter Container (AC)
Explanation: The Application Server Independent (ASI) JVM is the core Sterling B2B Integrator process. It runs the workflow engine, services, adapters, scheduler, and the embedded Jetty HTTP container that serves the web console. ASI is started by run.sh (or startWindowsService) and is the main process you see in process listings.
2An administrator must allow secure inbound traffic from external partners while keeping Sterling B2B Integrator off the internet. Which component is deployed in the DMZ for this purpose?
A.Adapter Container
B.Perimeter Server
C.OPS Server
D.Lightweight JDBC Adapter
Explanation: A Perimeter Server (PS) is a lightweight Java process placed in the DMZ that tunnels inbound and outbound traffic to ASI on the internal network. It lets the integrator stay behind the firewall while external partners connect to the DMZ host.
3Which databases are supported as the Sterling B2B Integrator V5.2.6 backend?
A.DB2, Oracle, and Microsoft SQL Server
B.DB2 and PostgreSQL only
C.MySQL, MariaDB, and Oracle
D.Sybase ASE and Informix
Explanation: Sterling B2B Integrator V5.2.6 supports IBM Db2, Oracle Database, and Microsoft SQL Server as its persistent store. The installer prompts for one of these and provisions the schema during installation.
4An administrator is preparing a clustered Sterling B2B Integrator install. Which two application server bundles can be selected during V5.2.6 install for the cluster mode?
A.Apache Tomcat or Jetty standalone
B.JBoss or WebSphere Application Server
C.GlassFish or WildFly
D.WebLogic or Oracle iAS
Explanation: Sterling B2B Integrator V5.2.6 ships with embedded options for JBoss or IBM WebSphere Application Server when cluster mode requires application server features. ASI itself is application-server-independent, but the install lets you select these bundles.
5Which UNIX/Linux script is used to install Sterling B2B Integrator V5.2.6 from a silent or interactive command line?
A.setup.exe
B.install.sh
C.configure.bat
D.deploy.jar
Explanation: On UNIX and Linux, install.sh located in the SI install media kicks off the installer. It accepts a silent install file (silent_install.cmd) or runs interactively, prompting for install directory, database, and ports.
6Which Sterling B2B Integrator script provides a snapshot of installation parameters, paths, and version data and is commonly attached to IBM support tickets?
A.dump_info.sh
B.envinfo.sh
C.version_check.sh
D.diagnostic.sh
Explanation: dump_info.sh (Linux/UNIX) and dump_info.cmd (Windows) print installation properties, ports, database configuration, JVM information, and product version. IBM support typically asks for dump_info output to triage installs and patches.
7Which command stops Sterling B2B Integrator immediately, terminating active business processes without waiting for them to finish?
A.softstop.sh
B.stopWindowsService.cmd
C.hardstop.sh
D.pausebp.sh
Explanation: hardstop.sh (or hardstop.cmd) terminates ASI and adapter containers immediately, without waiting for in-flight business processes to complete. It is used when softstop hangs or the system is unresponsive.
8An administrator wants permanent Sterling B2B Integrator property overrides that survive patches and upgrades. Which file should contain the overrides?
A.sandbox.cfg
B.customer_overrides.properties
C.noapp.properties
D.jvm.options
Explanation: customer_overrides.properties (under install_dir/properties) is the supported file for persistent property overrides. Values placed there override the corresponding *.properties files and are preserved across fix packs, patches, and upgrades.
9Which property file specifies JVM heap size, GC settings, and other JVM startup arguments for the Sterling B2B Integrator ASI process?
A.tuning.properties
B.jvm.options / jvm_options
C.performance.cfg
D.sandbox.cfg
Explanation: JVM startup arguments such as heap (Xms/Xmx), GC algorithm, and 32-bit/64-bit selection are configured via the jvm.options/jvm_options file used by Sterling B2B Integrator's startup scripts. Changes require restarting ASI.
10An administrator needs Sterling B2B Integrator to start automatically after a Linux reboot. Which is the recommended approach?
A.Add run.sh to /etc/inittab and run as root
B.Configure a systemd or init.d service that runs run.sh as the SI install user
C.Add run.sh to /etc/profile of the install user
D.Use crontab @reboot for the root account
Explanation: IBM's documented practice is to wrap run.sh in a systemd unit (or init.d script on older distributions) that runs as the non-root install user. Sterling B2B Integrator must not be run as root, and OS-managed service control gives clean dependencies and logging.

About the IBM Sterling B2B Integrator (C8060-218) Exam

The IBM Certified Solution Implementer - Sterling B2B Integrator V5.2 (C8060-218) certification validates the ability to install, configure, develop, administer, and troubleshoot Sterling B2B Integrator V5.2 deployments. It covers the V5.2.6 architecture (ASI, OpsServer, Adapter Container, Perimeter Server), GPM/BPML business process development, EDI translation, AS2/SFTP/FTP/OFTP/MLLP integrations, advanced trading partner profiles, system tuning, and operational troubleshooting. The credential is targeted at consultants, implementation engineers, and administrators working with Sterling B2B Integrator V5.2.

Assessment

Approximately 50-60 multiple-choice questions covering installation/configuration, business process development with GPM/BPML, integration and communication adapters/protocols, administration and operations, and troubleshooting. IBM does not publish the exact number of operational questions.

Time Limit

approximately 75-90 minutes

Passing Score

approximately 63%

Exam Fee

$200 USD (IBM / Pearson VUE)

IBM Sterling B2B Integrator (C8060-218) Exam Content Outline

20%

Installation and Configuration

V5.2.6 architecture (ASI, OpsServer, Adapter Container, Perimeter Server), Db2/Oracle/MSSQL, JBoss/WebSphere bundle, install.sh, dump_info, hardstop/softstop, customer_overrides.properties, jvm.options, install3rdParty, cluster vs non-cluster

20%

Business Process Development

Graphical Process Modeler (GPM), BPML primitives (operation, choice, scope, onFault, sequence, while, repeat), persistence levels (Full, Step Status, BP Start/Stop, None), Sync vs Async, BP versioning, Translation Service, Map Editor, Code Lists

20%

Integration and Communication

FTP/SFTP/HTTP/HTTPS adapters, AS2 with Drummond Group certification and MDN, OFTP/OFTP2, MLLP for HL7, RosettaNet PIPs, X12 (837/850/856/810/999), EDIFACT, TRADACOMS, advanced trading partner profile (Identity, Transport, Document Exchange, Delivery Channel, Packaging), envelopes

20%

Administration and Operations

User accounts and groups, schedules, MyPage dashboard, Workflow Reporting / BP monitor, Archive/Purge, Indexing, Mailbox routing rules, MESA alerts, JVM tuning, service configuration groups, audit logging, restart and recovery

20%

Troubleshooting

Logs (noapp.log, system.log, opsserver.log, node*AC* container logs), service-level log levels, dump_info bundles, hardstop vs softstop, AS2 trust/certificate problems, JDBC connection pool starvation, GC tuning, heap dumps with jcmd, archive restore

How to Pass the IBM Sterling B2B Integrator (C8060-218) Exam

What You Need to Know

  • Passing score: approximately 63%
  • Assessment: Approximately 50-60 multiple-choice questions covering installation/configuration, business process development with GPM/BPML, integration and communication adapters/protocols, administration and operations, and troubleshooting. IBM does not publish the exact number of operational questions.
  • Time limit: approximately 75-90 minutes
  • Exam fee: $200 USD

Keys to Passing

  • Complete 500+ practice questions
  • Score 80%+ consistently before scheduling
  • Focus on highest-weighted sections
  • Use our AI tutor for tough concepts

IBM Sterling B2B Integrator (C8060-218) Study Tips from Top Performers

1Memorize the four V5.2.6 process types: ASI (main JVM), OpsServer (cluster ops), Adapter Container (isolated adapter JVM), and Perimeter Server (DMZ tunnel) — questions repeatedly test which one does what
2Drill the four trading partner profile records — Identity, Transport, Document Exchange, Delivery Channel, Packaging — and which artifact holds certificates vs endpoints vs envelope rules
3Master the persistence levels (Full, Step Status / Engine May Override, BP Start/Stop, None) and remember that step-level error messages require Full or Step Status - Engine May Override
4Know the install scripts cold: install.sh, dump_info, install3rdParty, hardstop vs softstop, and InstallService.sh for fix packs — many troubleshooting questions hinge on the right command
5Review the supported protocols and what each is for: AS2 (Drummond Group certified, MDN receipts), SFTP (SSH), FTPS (TLS), OFTP/OFTP2 (automotive), MLLP (HL7), and the X12 transaction codes (837 claim, 850 PO, 856 ASN, 810 invoice)
6Practice reading logs: noapp.log/system.log for ASI, opsserver.log for cluster ops, and node*AC* directories for adapter container logs

Frequently Asked Questions

What is the C8060-218 IBM Sterling B2B Integrator certification?

C8060-218 is the IBM Certified Solution Implementer - Sterling B2B Integrator V5.2 exam. It validates the ability to install, configure, develop, administer, and troubleshoot Sterling B2B Integrator V5.2 deployments, including ASI/OpsServer/Adapter Container/Perimeter Server architecture, GPM/BPML business process development, EDI translation, AS2/SFTP/FTP/OFTP integrations, and trading partner onboarding.

Is C8060-218 a V5.2 or V6 exam — should I still take it in 2026?

C8060-218 covers Sterling B2B Integrator V5.2. The current product line is V6.x, but IBM has not yet released a V6 administrator/implementer exam, so C8060-218 remains the only bookable IBM implementer certification for Sterling B2B Integrator and is the right credential to pursue in 2026 if you work with the product.

How many questions are on the C8060-218 exam and how long is it?

IBM does not publicly state the exact question count or time limit for C8060-218. Based on IBM's standard exam format, candidates should plan for approximately 50-60 multiple-choice questions in roughly 75-90 minutes, with an approximately 63% passing score.

What does the C8060-218 exam cost and who administers it?

The C8060-218 exam costs $200 USD per attempt and is administered through Pearson VUE, either at a test center or via online proctoring. Candidates need a Pearson VUE account, valid government-issued photo ID, and IBM training profile to register.

What topics are heavily tested on C8060-218?

The exam emphasizes the V5.2.6 architecture (ASI, OpsServer, Adapter Container, Perimeter Server), business process development with GPM and BPML (including persistence levels, Sync vs Async, fault handling), integration via AS2/SFTP/FTP/OFTP/MLLP and EDI envelopes (X12, EDIFACT, TRADACOMS), advanced trading partner profiles (Identity, Transport, Document Exchange, Delivery Channel, Packaging), administration (Archive/Purge, schedules, JVM tuning), and troubleshooting from logs and dump_info.

How should I prepare for the C8060-218 exam?

Combine hands-on time with a Sterling B2B Integrator V5.2 install (running install.sh, dump_info, hardstop/softstop, configuring adapters, and inspecting logs) with IBM's official V5.2 documentation on GPM, BPML, persistence levels, and the trading partner profile. Use these 100 free practice questions to identify weak domains, then revisit the relevant IBM documentation for that area.

What experience level is recommended before taking C8060-218?

While there are no formal prerequisites, IBM aims this exam at candidates with hands-on Sterling B2B Integrator implementation experience. Most successful candidates have 6-12 months of real implementation work covering install, BP development, partner onboarding, and operational troubleshooting before sitting the exam.