Free Practice Questions for TP EIMSA
Exam-style questions and explanations by OpenExamPrep.
Loading practice questions...
Key Facts: TP EIMSA Exam
Level 3
National qualification level (RNCP38561 / EQF Level 3, Ministère du Travail)
France Compétences
5h 35m
Total candidate evaluation time: 5h 15m practical scenario (MSP in 2 parts) + 20m final interview
France Compétences RNCP38561
2 Blocs
Compulsory competence units: RNCP38561BC01 (Installer) and RNCP38561BC02 (Maintenance)
France Compétences RNCP38561
3h 15m
Practical wiring modification duration from technical dossier under invigilation
France Compétences RNCP38561
2029
RNCP38561 registration is active until 21 March 2029 (supersedes RNCP32297)
France Compétences
The TP Électricien d'Installation et de Maintenance des Systèmes Automatisés (Level 3, RNCP38561, active to 2029) is the French Ministry of Labour qualification for automated machinery electricians. Evaluated in French over 5h 35min — a 5h 15min practical scenario (3h 15m wiring modification, 30m commissioning, 55m troubleshooting/repair, 15m IoT sensor parameterisation, 20m preventive maintenance) plus a 20-minute final interview on the dossier professionnel — the certification covers cabinet assembly, integration, commissioning, repair, and safety. This 100-question practice bank is an English-language MCQ study adaptation; it is not an official translation and does not replace workshop practical testing.
Sample TP EIMSA Practice Questions
Try these sample questions to review concepts for the TP EIMSA exam. Each question includes a detailed explanation. Start the interactive quiz above for the full 100+ question experience with AI tutoring.
1According to standard EN 60204-1 (Safety of machinery - Electrical equipment of machines), which insulated conductor colour is mandatory for the protective bonding conductor (PE) in an industrial automated control cabinet?
2When wiring the internal control circuits of an automated machine cabinet according to EN 60204-1 recommendations, which wire colours designate AC control circuits and DC control circuits respectively?
3In an industrial control cabinet, certain circuits remain live even when the main supply disconnecting switch (sectionneur général) is switched to the OFF (0) position, such as interlocking signals from an adjacent machine. According to EN 60204-1, which wire colour must be used for these circuits?
4Why is it mandatory in industrial automated cabinet assembly to crimp bootlace ferrules (embouts de câblage) onto the stripped ends of flexible multi-strand (Class 5) copper conductors before inserting them into screw terminals?
5A wiring technician is installing slotted PVC trunking (goulotte de câblage) in a machine control cabinet. To comply with standard panel-building trade practices and allow for thermal dissipation as well as future wiring modifications, what is the recommended maximum cross-sectional wire fill factor (taux de remplissage)?
6An electrician must size a regulated 24 V DC switch-mode power supply (alimentation à découpage) for an automated packaging cell. The load inventory is: PLC CPU and rack drawing 1.2 A; 16 electro-pneumatic solenoid valves at 0.12 A each; 10 inductive proximity sensors at 0.025 A each; and 2 safety relay coils drawing 0.15 A each. To ensure reliability and provide a 25% reserve margin, which standard power supply rating should be selected?
7On an industrial electrical schematic drawn in accordance with standard EN 81346-2 and French panel-building conventions, how is an external terminal strip typically designated, and how are its individual terminals identified?
8To prevent electromagnetic interference (EMI/CEM) between high-power inverter outputs and sensitive low-voltage signals inside a control cabinet, what installation practice must be strictly observed?
9When connecting the braided copper shield of a motor power cable driven by a variable frequency drive (VFD) at the cabinet entry gland plate, what is the best practice for high-frequency noise suppression?
10A technician connects a standard 3-wire DC inductive proximity sensor (PNP, normally open) to a 24 V DC PLC digital input card. What are the standard wire colours and connections according to IEC 60947-5-2?
About the TP EIMSA Exam
The Titre Professionnel (TP) Électricien d'Installation et de Maintenance des Systèmes Automatisés is France's state-certified vocational qualification (Niveau 3 / EQF Level 3) for electricians specializing in automated machinery, control cabinet wiring, industrial equipment integration, and electrotechnical maintenance. Registered under France Compétences fiche RNCP38561 (active until 21 March 2029, superseding RNCP32297) and certifed by the Ministère du Travail, du Plein emploi et de l'Insertion, the title validates professionals who build, modify, commission, troubleshoot, and maintain automated industrial machinery and electrical control panels. The qualification encompasses two core competence blocs: RNCP38561BC01 (Installer des équipements automatisés: mounting and wiring control cabinets from schematics, routing cables, terminating ferrules and terminal strips, integrating field sensors and actuators, executing point-to-point continuity checks, insulation resistance testing at 500 V DC, and sequential commissioning); and RNCP38561BC02 (Assurer la maintenance d'équipements automatisés: structured electrical troubleshooting, multimeter voltage/resistance measurements, replacing defective contactors/relays/drives, parameterising IO-Link connected IoT sensors, performing preventive maintenance, retorquing terminals, thermographic inspection, NF C 18-510 5-step consignation, electrical PPE, and DEEE waste sorting). The official assessment is conducted in French through a 5h 15min practical scenario and a 20-minute final interview; this bank is an English-language MCQ study adaptation of the underlying theory, standards, and calculations.
Exam sponsor: Ministère du Travail, du Plein emploi et de l'Insertion / DREETS. The requirements and fees below concern the certification or admission exam, separate from our free practice resources.
Assessment
The assessment for the Titre Professionnel Électricien d'installation et de maintenance des systèmes automatisés (RNCP38561) comprises two main components totaling 5 hours 35 minutes of candidate evaluation time: 1. Mise en situation professionnelle (05 h 15 min total) divided into two parts: Première partie (03 h 45 min) consisting of a wiring modification on an automated system from a technical dossier under an invigilator (03 h 15 min), followed by commissioning of the automated equipment from a procedure in the presence of the jury (00 h 30 min); Deuxième partie (01 h 30 min) in the presence of the jury, consisting of fault-finding on faulted automated equipment, repair and commissioning from a procedure (00 h 55 min), verification of a connected IoT sensor parameterisation (00 h 15 min), and preventive maintenance of the equipment (00 h 20 min). 2. Entretien final (00 h 20 min) with the jury, which includes discussion of the candidate's dossier professionnel. The jury is habilitated by the territorial representative of the ministry (DREETS/DDEETS) and composed of qualified trade professionals. Candidates who validate both competence blocs (RNCP38561BC01 and BC02) are awarded the full Titre Professionnel; individual validated blocs are certified as Certificats de Compétences Professionnelles (CCP).
Time Limit
5h 35min
Passing Score
Validation of both competence blocs (RNCP38561BC01 and RNCP38561BC02) by the jury; partial validation is certified as individual CCPs
Exam / Certification Fees
No separate examination fee is published for the candidate: the validation session sits inside a funded pathway; AFPA prices the full qualifying course at 12,852 € net of tax
Exam sponsor websiteFees, eligibility, and exam policies can change. Confirm them with the exam sponsor before applying or paying.
Official sources
- France Compétences - Fiche RNCP38561 (TP Électricien d'installation et de maintenance des systèmes automatisés)
- Ministère du Travail - Titres Professionnels et Référentiels REAC / RE
- AFPA - Formation qualifiante Électricien d'installation et de maintenance des systèmes automatisés
- INRS - Risque électrique et habilitation NF C 18-510 (ED 6127)
Our practice resources: topics covered
We aim to reflect publicly available exam outlines and topic information in our study resources. Coverage, format, and difficulty may differ from the actual exam, and we cannot guarantee that every detail is accurate or current. Confirm exam requirements, fees, and policies with the official exam sponsor.
Cabinet Wiring & Field Integration
Industrial control panel component mounting, DIN rail layout, slotted ducting (goulottes) fill ratios, bootlace ferrules, terminal marking under EN 81346-2, conductor colour coding under EN 60204-1 (black power, red AC control, dark blue DC control, orange external interlocks, green/yellow PE), EMC cable separation and 360-degree shield bonding, 24 V DC switch-mode power supply sizing, and field device integration (inductive/photoelectric PNP sensors, safety switches, emergency stop dual channels, reversing contactors).
Commissioning & Electrical Testing
Pre-commissioning point-to-point continuity checks (sonnage), insulation resistance testing (500 V DC ≥ 1.0 MΩ under EN 60204-1), phase rotation checks (L1-L2-L3), three-phase motor active power and starting current calculations, star-delta motor coupling rules, three-phase voltage drop (ΔU) calculations, thermal overload relay setting, fuse coordination (aM vs gG), and PLC I/O checkout.
Fault Diagnosis & System Repair
Structured fault diagnosis methodology, half-split troubleshooting (dichotomie), multimeter voltage drop and resistance measurements, contactor contact degradation diagnosis, 24 V DC short-circuit/ground fault isolation, solenoid valve coil resistance checks, motor single-phasing detection, stator insulation breakdown testing, VFD fault diagnosis, and parameterising connected IoT sensors (IO-Link) using IODD device descriptions.
Preventive Maintenance & Electrical Safety
NF C 18-510 5-step electrical consignation (séparation, condamnation, identification, VAT with approved dedicated detector, MALT/CC), electrical PPE (1000 V insulating gloves, arc-flash face shield), employer-issued habilitation symbols and limits (BR, B1V, B2V, BC), terminal tightening torques, Joule heating prevention, infrared thermographic hotspot detection, cabinet cooling maintenance, DEEE / WEEE industrial waste sorting, hazardous lithium battery disposal, and motor energy efficiency (IE classes, Affinity laws).
Preparing for the TP EIMSA Exam
What You Need to Know
- Passing score: Validation of both competence blocs (RNCP38561BC01 and RNCP38561BC02) by the jury; partial validation is certified as individual CCPs
- Assessment: The assessment for the Titre Professionnel Électricien d'installation et de maintenance des systèmes automatisés (RNCP38561) comprises two main components totaling 5 hours 35 minutes of candidate evaluation time: 1. Mise en situation professionnelle (05 h 15 min total) divided into two parts: Première partie (03 h 45 min) consisting of a wiring modification on an automated system from a technical dossier under an invigilator (03 h 15 min), followed by commissioning of the automated equipment from a procedure in the presence of the jury (00 h 30 min); Deuxième partie (01 h 30 min) in the presence of the jury, consisting of fault-finding on faulted automated equipment, repair and commissioning from a procedure (00 h 55 min), verification of a connected IoT sensor parameterisation (00 h 15 min), and preventive maintenance of the equipment (00 h 20 min). 2. Entretien final (00 h 20 min) with the jury, which includes discussion of the candidate's dossier professionnel. The jury is habilitated by the territorial representative of the ministry (DREETS/DDEETS) and composed of qualified trade professionals. Candidates who validate both competence blocs (RNCP38561BC01 and BC02) are awarded the full Titre Professionnel; individual validated blocs are certified as Certificats de Compétences Professionnelles (CCP).
- Time limit: 5h 35min
- Exam / certification fees: No separate examination fee is published for the candidate: the validation session sits inside a funded pathway; AFPA prices the full qualifying course at 12,852 € net of tax Official sources
Using Our Practice Resources
- Work through all 100 available questions
- Review every answer and explanation
- Track weak areas and revisit them
- Use our AI tutor for tough concepts
TP EIMSA: Suggested Study Strategy
Frequently Asked Questions
What is the official format and duration of the TP Électricien d'Installation et de Maintenance des Systèmes Automatisés examination?
The RNCP38561 fiche specifies a total candidate assessment time of 5 hours 35 minutes before a jury of trade professionals habilitated by the DREETS/DDEETS. It consists of a 5-hour 15-minute practical scenario (mise en situation professionnelle) divided into two parts: Part 1 (3h 45min total: 3h 15min wiring modification on automated equipment from a technical dossier under invigilation, followed by 30min equipment commissioning before the jury); Part 2 (1h 30min total with jury: 55min fault-finding, repair, and commissioning; 15min verification of connected IoT sensor parameterisation; and 20min preventive maintenance). The session concludes with a 20-minute final interview (entretien final) covering the candidate's professional dossier (dossier professionnel).
Does this English-language practice bank replace the official workshop assessment?
No. The official French assessment is hands-on and performance-based, conducted on real automated industrial machinery and electrical cabinets in French. This 100-question practice bank is an English-language MCQ study adaptation designed to help learners and technicians master the underlying electrical engineering principles, standard formulas, wire color conventions, testing procedures, safety regulations, and troubleshooting methodologies. It does not replace workshop practice or the oral examination.
Is an NF C 18-510 electrical authorization an entry prerequisite for this Titre Professionnel?
No. The RNCP38561 certification fiche lists no prerequisite for entry. Under French labor law (Code du Travail), an electrical authorization (habilitation électrique NF C 18-510, such as symbol BR or B2V) is an individual legal document issued exclusively by an EMPLOYER based on medical fitness and safety training for tasks carrying electrical risk in the workplace. It is not an entry requirement or diploma component of the certification itself, although candidates are thoroughly trained in the 5-step consignation procedure and VAT safety protocols.
What is the difference between TP EIMSA (Level 3) and TP Technicien de Maintenance Industrielle (Level 4)?
The TP Électricien d'Installation et de Maintenance des Systèmes Automatisés (RNCP38561) is a Level 3 (CAP/BEP level) qualification focused squarely on the electrical and automated aspects of machinery: cabinet layout, wiring modifications, field sensor/actuator integration, electrical commissioning, and electrical troubleshooting. In contrast, the TP Technicien de Maintenance Industrielle (TMI, RNCP41536) is a Level 4 (Bac level) multi-technical qualification that encompasses mechanical transmission repair, shaft alignment, bearing mounting, industrial hydraulics, pneumatic circuits, manual machining, and welding, alongside advanced predictive maintenance (AMDEC/GMAO).
How is the Titre Professionnel awarded upon completion?
The complete Titre Professionnel is awarded when the candidate successfully validates both compulsory competence blocs: RNCP38561BC01 (Installer des équipements automatisés) and RNCP38561BC02 (Assurer la maintenance d'équipements automatisés). If only one bloc is validated, the candidate receives a Certificat de Compétences Professionnelles (CCP) for that bloc, which is permanently retained, and can present the remaining bloc in a subsequent session within the validity period of the title.