Per NFPA 780 (2020), Class I lightning-protection materials are required on ordinary structures of what maximum height?
Nfpa 780
Question · Easy
What is the minimum cross-sectional area of a Class I main copper lightning conductor in NFPA 780 (2020)?
What is the minimum cross-sectional area of a Class I main aluminum lightning conductor in NFPA 780 (2020)?
Question · Medium
Trades Exam Prep Podcast
Listen on Spotify
Podcast
What is the minimum cross-sectional area of a Class II main copper lightning conductor in NFPA 780 (2020)?
What is the minimum diameter of a solid Class I copper air terminal in NFPA 780 (2020)?
What is the minimum diameter of a solid Class II copper air terminal in NFPA 780 (2020)?
What is the minimum diameter of a solid Class I aluminum air terminal in NFPA 780 (2020)?
A Class I main copper conductor must have at least 57,400 circular mils. What is the smallest standard AWG size that meets that NFPA 780 (2020) area?
Question · Hard
What is the minimum weight of a Class I main copper lightning conductor per 1,000 ft in NFPA 780 (2020)?
An ordinary commercial building in South Carolina measures 80 ft from grade to the highest roof. Which NFPA 780 (2020) material class is required?
Per NFPA 780 (2020) 4.6.2, the tip of an air terminal shall be not less than how far above the object or area it is intended to protect?
What is the maximum spacing along a roof ridge or perimeter for standard air terminals 24 in or less in height under NFPA 780 (2020)?
When air terminals taller than 24 in (610 mm) are used, NFPA 780 (2020) permits perimeter or ridge spacing up to which maximum, provided the rod is supported at not less than one-half its height?
Strike-termination devices shall be located at or within what distance of ridge ends, outside corners, and roof edges per NFPA 780 (2020)?
On a flat or gently sloping roof, no point on the roof shall be more than what distance from the nearest strike-termination device under NFPA 780 (2020)?
An air terminal 36 in tall is installed on a Class I roof ridge. In addition to the 25 ft spacing allowance, where must that rod be supported?
A rooftop metal body may be used as a strike-termination device without a dedicated air terminal when it is electrically continuous and has a metal thickness of not less than which value?
A straight roof ridge is 80 ft long. Using 24 in Class I air terminals, terminals must be within 2 ft of each end and spaced not more than 20 ft apart. What is the minimum number of air terminals required on that ridge?
What rolling-sphere radius does NFPA 780 (2020) use to define the ordinary-structure zone of protection?
Using the NFPA 780 (2020) 150 ft rolling-sphere model, what is the horizontal protected distance at grade from a 30 ft-high strike-termination device? Use d = √[h(2R − h)], where R = 150 ft.
NFPA 780 (2020) 4.8.1 permits the protective-angle method with one angle from grade to 25 ft and another from 25 ft to 50 ft. Which method must be used to evaluate protection of surfaces more than 50 ft below the strike-termination device?
Each strike-termination device shall have a minimum of how many paths to ground in an NFPA 780 (2020) ordinary-structure system?
What is the minimum number of down conductors required on any ordinary structure protected to NFPA 780 (2020)?
Down conductors shall be spaced at intervals averaging not more than which distance around the structure perimeter?
Structures exceeding which perimeter must have a down conductor for every 100 ft of perimeter or fraction thereof?
No bend of a lightning conductor shall form an included angle of less than which value?
What is the minimum bend radius permitted for lightning conductors in NFPA 780 (2020)?
Lightning conductors shall be fastened at intervals not exceeding which distance?
A rectangular building has a protected perimeter of 360 ft. What is the minimum number of down conductors required by NFPA 780 (2020)?
A 40 ft by 40 ft one-story shop has a 160 ft perimeter. What is the minimum number of down conductors required?
A 90 ft by 60 ft warehouse has a 300 ft perimeter. What is the minimum number of down conductors required by NFPA 780 (2020)?
Where should the two or more required down conductors be located on an ordinary structure?
Why does NFPA 780 require bonding of grounded metal bodies that lie within the calculated bonding distance of a lightning conductor?
NFPA 780 (2020) calculates bonding distance with which formula?
In the NFPA 780 bonding-distance formula, what value of n is used when only one down conductor lies within a 100 ft (30 m) radius of the metal body?
A grounded rooftop pipe is 30 ft above the nearest lightning-protection ground reference. There is one down conductor in the 100 ft zone and the flashover path is through air (Km = 1). What is the calculated bonding distance D?
A grounded metal body is 36 ft above the nearest lightning-protection ground reference. Two down conductors at least 25 ft apart lie in the 100 ft zone, and the path is through air (Km = 1). What is D?
A rooftop HVAC unit is 4.0 ft from a down conductor. The unit is 30 ft above the lightning-protection ground reference, two qualifying downs are in the zone (n = 1.5), and the gap is through air (Km = 1). Is a bond required?
In the bonding-distance formula, what value of Km is used when the potential flashover path is through solid building material such as concrete, brick, or wood?
What value of n is used when three or more down conductors, each spaced at least 25 ft (7.6 m) apart, lie within a 100 ft (30 m) radius of the metal body?
A grounded steel column is 24 ft above the lightning-protection ground reference. One down conductor is in the zone and the path is through masonry (Km = 0.50). What is D?
Bonding plates used to connect a lightning conductor to a metal body shall have a minimum surface contact area of which value?
Which of the following grounded systems must be interconnected to the lightning protection system with main-size conductors?
How does NFPA 780 (2020) define a grounded (non-isolated) metal body?
What is the minimum diameter of a ground rod used as an NFPA 780 (2020) lightning-protection grounding electrode?
An NFPA 780 (2020) ground rod shall extend vertically not less than how far into the earth?
What is the minimum manufactured length of an NFPA 780 (2020) ground rod?