What initial training requirement must a C-47 contractor fulfill before obtaining authorization to perform manufactured home installations?
Planning And Estimating
Question · Easy
A 14-foot wide single-section manufactured home has a total roof live and dead load of 40 psf. If piers are spaced at 6-foot intervals along each main chassis beam, what concentrated load must each intermediate chassis pier support?
Question · Hard
When planning the installation of a manufactured home on a private lot outside a mobilehome park in California, which agency issues the installation permit?
Trades Exam Prep Podcast
Listen on Spotify
Podcast
What primary technical document governs the structural setup, blocking, and tie-down locations during the installation of a new manufactured home?
Question · Medium
A pier block supports a concentrated load of 4,500 lbs. If the site soil has an allowable soil bearing capacity of 1,500 psf, what minimum pre-cast concrete footing pad area is required?
What must a C-47 contractor verify regarding site utility connection points before finalizing an installation cost estimate?
Where are perimeter piers required along the exterior marriage line of a multi-section manufactured home?
How often must certified manufactured home installers complete continuing education requirements to maintain active certification status in California?
When planning an installation in a California mountain zone with a roof snow load exceeding 40 psf, what structural design requirement applies?
A contractor is estimating 6-mil polyethylene ground vapor retarder material for a 28 ft x 60 ft multi-section home crawl space. Allowing 10% extra for seam overlaps, how much plastic sheeting is required?
When planning hardware takeoffs for marriage line structural attachment, what fastener type is specified by standard DAPIA details for joining floor rim joists?
What is the primary scope limitation of a C-47 General Manufactured Housing classification license issued by CSLB?
A 60-foot manufactured home requires diagonal ground anchors spaced at a maximum of 6 feet on center along both main chassis beams. What minimum number of diagonal anchors is required?
When estimating contract pricing, what document must a C-47 contractor provide to home purchasers before executing the purchase agreement?
What site access dimension must a C-47 contractor verify during pre-installation job site planning for multi-section transport delivery?
What default allowable soil bearing capacity must be assumed for foundation pad sizing when soil testing is not conducted?
Site Preparation
What slope requirement applies to site grading surrounding a manufactured home pad?
What is the minimum required vertical clearance between the unexcavated ground surface and the bottom of the main steel chassis beams?
What pre-installation site clearing operation is required before placing concrete footing pads?
What installation standard applies to ground vapor retarders placed under manufactured homes?
When constructing continuous concrete footings in areas subject to freezing temperatures in California, what depth requirement applies to footings?
Where should site utility service risers (water, gas, sewer) be located relative to the manufactured home footprint during site prep?
What minimum thickness is required for poured-in-place concrete footing pads under federal installation standards?
A pier carries a total structural load of 3,600 lbs. If soil test data indicates an allowable soil bearing capacity of 2,000 psf, what is the minimum required footing footprint size?
What site preparation measure must be installed if high groundwater or surface runoff threatens under-floor crawl space areas?
What is the minimum required separation distance between manufactured home walls on adjacent mobilehome park lots?
When placing foundation pads on imported fill material, what compaction standard is required by site engineering guidelines?
What requirement applies to crane placement pads when hoisting manufactured home modules over site obstacles?
Where must the main gas shutoff valve be located relative to the site supply riser?
What minimum depth below finish grade must water supply lines be buried on site to comply with California plumbing standards?
What slope requirement applies to site sewer drainage piping connecting the home drop point to the park sewer riser?
What working space clearance must be maintained around electrical service pedestals on park lots?
When constructing piers using 8x8x16 concrete masonry units under federal installation standards, how must the block cells be oriented?
Manufactured Home Installation
Under federal installation standards, single-open-cell block piers may be used up to what maximum pier height before double-block corner interlocking is required?
What cap block material combination is permitted on top of a concrete masonry block pier under federal installation standards?
What rule governs the installation of wood shims placed between the cap block and the steel chassis beam?
A 16 ft x 70 ft single-wide home main beam carries 500 lbs per linear foot. If each pier has a maximum allowable capacity of 3,000 lbs, what maximum pier spacing along the main I-beam is permitted?
What primary alignment step must be completed before bolting marriage line wall studs together on a double-wide manufactured home?
According to DAPIA structural connection details, how are ridge beam marriage line connections secured in multi-section homes?
What weatherproofing detail must be installed along the roof marriage line seam during multi-section assembly?
What purpose does the marriage line floor gasket serve during multi-section home setup?
When connecting under-floor crossover heating ducts between home sections, what attachment method is required?
How must electrical crossover circuits between multi-section home units be enclosed under California Electrical Code?
What requirement applies to ABS drain-waste-vent crossover piping connections under multi-section manufactured home floors?
When installing ground anchors, at what angle should diagonal tie-down anchors be driven into the earth?
How are diagonal tie-down straps attached to the main steel chassis beams of a manufactured home?
Under state seismic tie-down standards, what primary purpose do longitudinal ground anchors serve?
Loading more…