According to the ICB certification information provided for this practice bank, how many total items are on the TABB Technician certification exam?
Tabb Technician Exam Logistics
Question · Easy
What score is required to pass the TABB Technician certification exam based on the official facts used for this practice bank?
Which work scope best matches a TABB Testing, Adjusting and Balancing Technician?
Tabb Technician Scope
Trades Exam Prep Podcast
Listen on Spotify
Podcast
Which pair of systems is most central to the TABB Technician certification scope?
What does TAB stand for in HVAC field work?
Which formula gives airflow through a duct or opening when area and average velocity are known?
Tabb Technician Math
A rectangular duct is 24 inches by 12 inches. What is its cross-sectional area in square feet?
In standard air TAB calculations, velocity pressure is most commonly expressed in which unit?
Tabb Technician Airflow Fundamentals
Which relationship is correct for air pressure components in a duct?
Which instrument is normally used with a traverse to determine average velocity pressure in a duct?
Tabb Technician Instrumentation
Which instrument is most appropriate for checking electrical current on a fan motor without opening the circuit?
Tabb Technician Electrical
For hydronic balancing, gallons per minute is a unit of what quantity?
Tabb Technician Hydronic Distribution
Which device is commonly used to read pressure drop across a calibrated hydronic balance valve?
Tabb Technician Hydronic Measurements
Which heat-transfer equation is commonly used for sensible heat in an air stream?
Tabb Technician Heat Transfer
Which heat-transfer equation is commonly used for water coils when flow and temperature difference are known?
In psychrometrics, dry-bulb temperature is best described as what?
Tabb Technician Psychrometrics
What does relative humidity describe?
Which project document usually states the required airflow and water flow values that the TAB technician must verify?
Tabb Technician Project Documents
Before final TAB readings are taken, which condition is most important?
Tabb Technician Preliminary Tab
Which condition should a technician normally report as a deficiency before attempting final balance?
Which air terminal device is commonly used to measure supply or return volume directly at a diffuser or grille?
Tabb Technician Air Measurements
Which action best supports instrument accuracy?
Which fan component primarily adds energy to the air stream?
Tabb Technician Hvac Equipment
In a VAV air system, what does VAV mean?
Tabb Technician Air Distribution
What is the main purpose of a balancing damper?
What is the main purpose of a hydronic balancing valve?
Which component circulates water through a hydronic system?
In the basic vapor-compression refrigeration cycle, which component raises refrigerant pressure?
Tabb Technician Refrigeration
Which practice best supports TAB report data integrity?
Tabb Technician Reports
Which safety practice is most appropriate before measuring or adjusting energized HVAC equipment?
Tabb Technician Safety
A duct has an area of 3.0 square feet and an average velocity of 850 fpm. What is the airflow?
Question · Medium
A 20 inch by 18 inch duct has an average measured velocity of 720 fpm. Approximately what is the airflow?
Using V = 4005 x square root of velocity pressure for standard air, what velocity corresponds to 0.25 inches w.g. velocity pressure?
A Pitot reading shows total pressure of 1.20 inches w.g. and static pressure of 0.75 inches w.g. What is the velocity pressure?
A fan delivers 4000 cfm at 900 rpm. If speed is increased to 990 rpm and system conditions remain similar, what airflow is expected by the fan laws?
A fan static pressure is 2.0 inches w.g. at 1000 rpm. If speed is reduced to 900 rpm on the same system, what static pressure is expected by the fan laws?
A fan brake horsepower is 5.0 hp at full speed. If speed is reduced to 80 percent on the same system, approximately what horsepower is expected?
A supply fan is low on airflow and all branch dampers are wide open. Which condition is a likely system-side cause?
During a duct traverse, why are multiple readings taken across the duct instead of one centerline reading?
A terminal unit is scheduled for 800 cfm and measured at 720 cfm. What percent of design is it delivering?
A diffuser is 20 percent low. The measured flow is 320 cfm. What is the design flow?
A duct leakage test is intended to verify what condition?
Which condition generally increases duct friction loss?
Which fitting condition is most likely to create a dynamic loss and unstable measurement location?
A chilled-water coil has 12 gpm and a 10 F temperature rise. What is the approximate heat transfer?
An air-handling unit supplies 5000 cfm with a 20 F cooling coil dry-bulb temperature drop. What is the approximate sensible cooling?
A mixed-air plenum has 25 percent outdoor air at 30 F and 75 percent return air at 70 F. Ignoring heat gain, what mixed-air temperature is expected?