In an HVAC ladder (line) diagram, what do the two vertical lines on the left and right represent?
Control Circuits Ladder Diagrams
Question · Easy
On a ladder diagram, loads (such as relay coils and motors) and switching contacts should be arranged so that the:
A set of normally open (N.O.) contacts in a control circuit will:
Trades Exam Prep Podcast
Listen on Spotify
Podcast
Most residential and light-commercial HVAC control circuits operate at what nominal voltage?
A control transformer with a 120 V primary and 24 V secondary rated at 40 VA can supply a maximum secondary current of approximately:
Question · Medium
When two control transformers are connected in parallel to increase available VA, you must ensure that they are:
Question · Hard
In HVAC thermostat terminal designations, what does the 'C' terminal provide?
Thermostats Sensors
On a conventional cooling thermostat, which terminal carries the call for the compressor (cooling)?
The heat anticipator in a mechanical (bimetal) heating thermostat is best described as a:
If a heat anticipator is set with too low an amperage value (lower than the actual circuit current), the typical result is:
A thermistor used as an HVAC temperature sensor changes its:
For an NTC (negative temperature coefficient) thermistor, as the sensed temperature increases, its resistance:
A thermocouple, as used in a standing-pilot flame-safety circuit, generates a small DC voltage by the:
A pressure transducer in a modern HVAC system typically outputs which signal proportional to the sensed pressure?
The difference between the setpoint at which a control turns a load ON and the point at which it turns the load OFF is called the:
An electromechanical relay used in HVAC controls primarily allows a:
Relays Contactors Sequencers
The main difference between a contactor and a general-purpose control relay is that a contactor is:
A definite-purpose contactor used on a residential condensing unit commonly has a coil voltage of:
A sequencer in an electric-heat furnace is used to:
A potential (voltage) relay used to drop out the start capacitor of a single-phase compressor opens its contacts based on:
When troubleshooting a relay coil, an ohmmeter reading of infinite (OL) resistance across the coil indicates the coil is:
Contactor or relay contacts that are pitted, burned, and high in resistance will most likely cause:
Direct Digital Control (DDC) differs from traditional pneumatic and electromechanical control mainly because DDC:
Electronic Ddc Bas Controls
Which open communication protocol was developed specifically by ASHRAE for building automation and control networks?
In a DDC controller, a binary (digital) input is typically used to read:
A 0-10 VDC analog output from a DDC controller is most commonly used to:
In a PID control loop, the integral (I) term primarily acts to:
Proportional-only control in HVAC is characterized by an inherent:
A spring-return modulating damper actuator that fails on loss of power will:
An ECM (electronically commutated motor) blower differs from a standard PSC motor because the ECM:
A solid-state (electronic) ignition module that energizes a hot surface igniter and then proves flame is performing what control function?
Flame rectification, used by electronic ignition modules to prove a flame, works because the flame:
A high-limit safety control on a gas furnace heat exchanger is designed to:
Safety Limit Controls
A rollout switch on a gas furnace is a safety device that trips when:
The pressure switch (draft-proving switch) wired to a furnace inducer motor proves that:
A low-pressure cutout in a refrigeration control circuit protects the system by stopping the compressor when:
A high-pressure control that requires the technician to physically reset it after a trip is described as a:
A freeze-stat (low-temperature limit) on a chilled-water or hydronic air handler is installed to:
An anti-short-cycle (time-delay) control on an air conditioner protects the compressor by:
In a basic cooling sequence of operation, when the thermostat calls for cooling, the 'Y' signal first energizes the:
Sequence Of Operation Troubleshooting
In a standard gas-furnace heating sequence, the indoor blower (fan) is energized by the:
A technician finds 24 VAC at the R-to-C terminals but 0 V from R to W during a heat call with the thermostat closed. The most likely problem is:
A condenser fan and compressor will not start; the technician measures 24 VAC across the contactor coil but the contactor does not pull in. The most likely fault is:
When troubleshooting a 24 V control circuit, a blown low-voltage fuse that re-blows immediately after replacement most likely indicates:
A 'hopscotch' (hot-check) troubleshooting method on a ladder diagram involves:
In a ladder diagram, a single relay coil with two separate sets of contacts on different rungs is an example of:
A holding (seal-in) contact in a motor start/stop control circuit is used to: