In the basic vapor-compression refrigeration cycle, which component is responsible for absorbing heat from the conditioned space?
Refrigeration Cycle And Components
Question · Easy
Gray body, yellow top
Short
What is the primary function of the compressor in a refrigeration system?
Superheat is defined as the difference between the:
Question · Medium
Trades Exam Prep Podcast
Listen on Spotify
Podcast
A technician measures a suction line temperature of 50 F at a saturation temperature of 40 F. What is the superheat?
Subcooling is best described as liquid refrigerant that is:
Never vent refrigerant
Which metering device maintains a constant superheat at the evaporator outlet by modulating refrigerant flow in response to load?
In a TXV, the three forces acting on the diaphragm are bulb pressure, evaporator (spring-adjusted) pressure, and:
Question · Hard
What is the purpose of a filter-drier installed in the liquid line of a refrigeration system?
Bubbles seen in a liquid-line sight glass during steady operation most commonly indicate:
The accumulator in a refrigeration system is installed in the suction line primarily to:
During the latent heat process in the evaporator, the refrigerant:
One ton of refrigeration is equal to the removal of how much heat per hour?
The latent heat of fusion of water (ice melting) is approximately:
Which condenser type rejects heat to circulating water that is then cooled in a cooling tower?
A reciprocating compressor that has lost its valve seal (worn valves) will most likely show:
The compression ratio of a compressor is calculated as:
What is the purpose of a hot-gas defrost system in a commercial low-temperature evaporator?
A receiver in a refrigeration system is used to:
Higher-than-normal head (discharge) pressure on an air-cooled system is most commonly caused by:
In a refrigeration system, the metering device creates a pressure drop that causes some refrigerant to flash. This flash gas:
Oil return to the compressor in a properly designed system is ensured primarily by:
Which statement about a capillary tube metering device is correct?
A scroll compressor compresses refrigerant using:
An externally equalized TXV is required (instead of internally equalized) primarily when:
The high side of a refrigeration system includes which of the following components?
Non-condensable gas (air) trapped in a refrigeration system will collect in the:
A liquid-line restriction (such as a partially plugged filter-drier) typically produces:
Ohm's law states that voltage equals:
Electrical Fundamentals And Motors
A 240-volt heating element draws 10 amps. What is its power consumption?
In a series circuit, the total resistance is found by:
Two 20-ohm resistors connected in parallel produce a total resistance of:
In a single-phase PSC (permanent split capacitor) motor, the run capacitor is connected:
The purpose of a start capacitor on a single-phase compressor motor is to:
On a hermetic compressor, the three terminals are commonly identified as:
A capacitor that reads shorted on an ohmmeter (continuous low resistance) should be:
A contactor in an HVAC unit is used to:
A potential (voltage) relay used to drop out a start capacitor operates based on:
An ECM (electronically commutated motor) condenser or blower motor differs from a PSC motor in that it:
Three-phase power is commonly used for larger HVACR compressors because it:
Reversing two of the three line leads on a three-phase motor will:
Locked rotor amperage (LRA) refers to the current a motor draws:
A motor that hums but will not start, then trips on overload, most likely has:
A step-down control transformer in residential HVAC commonly reduces 120 or 240 volts to:
Complete combustion of natural gas produces primarily carbon dioxide, water vapor, and:
Heating Systems And Combustion
The three requirements for combustion (the fire triangle) are fuel, heat, and: