Which authority administers the Romanian electrician authorization procedure under Order 66/2023?
Legislation Regulations
Question · Easy
Under Article 9 of the ANRE authorization regulation, which work falls within Grade I's technical scope? Assume all other legal conditions are satisfied.
For ANRE Grades II–IV, what do authorization types A and B distinguish?
Engineering Exam Prep Podcast
Listen on Spotify
Podcast
An electrician holds Grade IIB only. A client requests execution of a 6 kV installation, regardless of its modest power. What is the correct scope decision under Article 9?
Question · Medium
An ANRE authorization's five-year periodic endorsement (vizare periodică) has expired. What follows from Article 18 of the authorization regulation?
During execution, an authorized electrician identifies a technical nonconformity in the design. Which response follows the duties in Article 37 of the ANRE regulation?
In a TN-S installation, which arrangement distinguishes the protective conductor from the neutral downstream of the supply point?
Technical Regulations
A designer proposes an RCD in the TN-C portion of a TN-C-S supply, before PEN separation. Which correction is needed?
What does an RCD principally detect?
Use the overload design condition Ib ≤ In ≤ Iz. With design current Ib = 18 A and corrected cable capacity Iz = 24 A, which listed device rating meets this condition?
A cable passes from open air into thermal insulation for part of its route. Which capacity governs selection where that section can overheat?
What is the principal purpose of protective equipotential bonding?
A three-phase board supplies single-phase electronic loads with substantial third-harmonic current. Which neutral-conductor assumption needs correction?
Which evidence best supports selectivity between upstream and downstream protective devices over the prospective fault-current range?
A cable's tabulated capacity is 30 A. Apply grouping and temperature factors of 0.70 and 0.90. With Ib = 18 A, what follows if only 16 A and 20 A breakers are available and Ib ≤ In ≤ Iz is required?
Question · Hard
Prospective short-circuit current at a board is 8 kA. No verified backup-protection arrangement is available. Which listed breaking capacity is adequate there, assuming all other conditions are met?
A board has both a grid supply and a photovoltaic inverter connection. Before work treated as dead, what must the isolation plan address?
Safety Occupational Health
An appropriate voltage detector indicates no voltage at the isolated work location. Which additional check helps establish that this result is trustworthy?
A person is touching an energized conductor. What is the first electrical-safety priority for a witness who can operate a safe, accessible disconnect?
An RCD's test button trips the device. Which conclusion is justified?
Why should PE not be used as the normal return conductor for a single-phase load?
An IT system's insulation monitor signals a first insulation fault. Which response is appropriate?
An insulation-resistance test is planned on a circuit with electronic controls and surge protective devices. What should be checked before applying test voltage?
Use the simplified TN check Zs × Ia ≤ U0. U0 = 230 V, measured Zs = 1.0 Ω, and the device needs Ia = 300 A for the required disconnection time. Which proposal satisfies this check, with other conditions unchanged?
A balanced three-phase load takes 20 A at 400 V line-to-line and power factor 0.80. What active power does P = √3 × U × I × cos φ give?
Electrical Engineering Calculations
A 230 V single-phase resistive load draws 20 A through a copper circuit 50 m long one way, using 6 mm² conductors. Given ρ = 0.0175 Ω·mm²/m, neglect reactance and use ΔU = 2ρLI/S. What is the voltage drop and percentage?
An ideal three-phase transformer is rated 100 kVA with 400 V secondary line-to-line voltage. What is its rated secondary line current?
Active power stays at 80 kW. Initial reactive power is 60 kvar and desired remaining reactive power is 20 kvar, both inductive. Ignoring losses and harmonics, what capacitor rating and resulting power factor are required?
For this adiabatic exercise, use S ≥ I√t/k with I = 5,000 A, t = 0.20 s, and a given factor k = 115 A·√s/mm². Which is the smallest listed section satisfying the check?
A motor delivers 12 kW mechanical output at efficiency 0.90 and power factor 0.80 on a balanced 400 V three-phase supply. What is its approximate line current?