Which standard supplies the design safety requirements for machinery-room ventilation in a new closed-circuit ammonia refrigeration system?
Safety Standards Practices
Question · Medium
When establishing a maintenance schedule for a relief valve that discharges internally into a closed-circuit ammonia system, which approach follows IIAR guidance?
Federal workplace rule intended to prevent or limit catastrophic releases of toxic, reactive, flammable or explosive chemicals at covered worksites.
Workplace hazards
Guess the Term
Introduction & Exam Overview
1.1 Current Exam Facts
Study guide
Which job on an OSHA PSM-covered ammonia process triggers management of change under 29 CFR 1910.119(l)?
Read the clue and guess the term in 6 tries.
Game
Which provision belongs in an emergency action plan required under OSHA 29 CFR 1910.38(c)?
Question · Easy
Written procedure for reviewing modifications to chemicals, technology, equipment or procedures before they are made, except for replacements in kind.
Which vessel dimensions are used in the conventional fire-exposure calculation C = f × D × L for minimum required refrigerant vessel relief capacity?
Question · Hard
Before opening an ammonia refrigerant line for maintenance on a PSM-covered process, what must the safe work procedure account for?
Document that must include sections on first-aid measures, fire-fighting measures and handling and storage for each hazardous chemical.
1.2 Test-Day Tools, On-Screen References, and Calculators
What can the Clean Air Act §112(r)(1) General Duty Clause require at a stationary ammonia refrigeration facility below the federal RMP threshold?
Swap tiles to line up three of the same term.
Term Match
When must an employer begin investigating an incident that caused, or could reasonably have caused, a catastrophic release from a PSM-covered process?
Clean Air Act Section 112(r) rule requiring facilities that use extremely hazardous substances to file chemical accident prevention documents with EPA.
Under OSHA PSM mechanical integrity, what determines inspection and testing frequencies for ammonia process equipment?
Which records belong together in the equipment portion of the process safety information required by 29 CFR 1910.119(d)(3)?
Motor controller that sets an AC motor's speed by changing the hertz of its power supply, now industry's usual choice for speed control.
Electricity
1.3 CIRO vs CARO and the RETA Credential Path
What is the NIOSH 15-minute recommended exposure limit for ammonia?
Flip two cards at a time to find matching terms.
Term Pairs
What establishes electrical isolation before qualified personnel work on normally energized parts of a refrigeration compressor motor circuit?
A service is called three-___ when it uses three current-carrying conductors that are offset from one another in time.
On a wye-delta start for a large ammonia compressor motor, the main purpose of the wye stage is to:
A compressor package with an independent prelubrication pump requires proof of adequate oil differential pressure before starting. Which input belongs in the motor-start permissive circuit?
Ratio of cooling delivered to energy consumed, with both measured in the same units.
Heat Flow
IIAR and ASHRAE Standards
2.1 IIAR 2 and ASHRAE 15 Machinery-Room Design
What can happen if a three-phase compressor motor loses one phase while it is running under load?
Find five hidden terms in a grid of letters.
Term Search
The measured line-to-line voltages at a three-phase motor are 478 V, 460 V and 441 V. What is the NEMA percent voltage unbalance to the nearest whole percent?
General term for heat that changes a substance's phase without changing its temperature, whether melting, boiling, condensing or freezing.
Why does the screw-compressor manufacturer's prestart checklist call for verifying the drive motor's direction of rotation?
A correctly sized VFD (variable frequency drive) on an industrial ammonia condenser fan motor primarily aims to:
Kind of gas that does not participate in the refrigeration effect, forms in greater amounts at higher ambient temperatures, and only gets compressed.
2.2 IIAR 6 Inspection, Testing, and Maintenance
Power factor correction capacitors installed at a refrigeration plant primarily:
Trades Exam Prep Podcast
Listen on Spotify
Podcast
A compressor motor repeatedly trips on thermal overload. Which comparison best helps distinguish an electrical supply problem from elevated compressor load?
___ pressure: condensing pressure that can be allowed to fall with outdoor temperature to cut compressor energy.
Monitoring System Performance
On a pressure-enthalpy (P-h) diagram for ammonia, the horizontal distance between the evaporator outlet and compressor inlet along an isobar represents:
Coefficient of performance (COP) for a refrigeration cycle is defined as:
Pattern of change in repeated readings that predictive maintenance uses to catch a machine problem before failure.
2.3 IIAR 7 Operating Procedures and IIAR 9 Existing Systems
For a simplified steady-state calculation using an overall evaporator heat-transfer coefficient U, which expression gives the coil heat-transfer rate?
At the same refrigeration load and condenser water flow, what typically happens when water entering a water-cooled condenser warms from 70°F to 85°F and condensing pressure can float?
Self-contained mechanical metering device that holds a set superheat, unlike its electronic counterpart, which needs a control system and an actuator.
Valves, Controls and DX Systems
Using the ASHRAE R-717 table that sets saturated liquid enthalpy to zero at −40°F, what is the approximate enthalpy of saturated ammonia vapor at 0°F?