Which standard is cited as the means of compliance with the Gas (Safety and Measurement) Regulations 2010 and NZ Building Code clause G11 for general gas installations in New Zealand?
As Nzs 5601 Gas Installations
Question · Easy
Natural gas is supplied as a 'second family' gas. Approximately what is its relative density compared with air?
Lpg Natural Gas Properties
Commercial propane (LP Gas) has a relative density of approximately 1.5. What is the main safety implication of this property?
Trades Exam Prep Podcast
Listen on Spotify
Podcast
What is the approximate flammability (explosive) range of natural gas in air?
Question · Medium
Approximately what is the flammable range of LP Gas (propane) in air?
Which product of incomplete combustion of a gas appliance is the toxic, odourless gas most dangerous to occupants?
Appliance Installation Commissioning
A correctly adjusted gas burner producing complete combustion will typically show what flame appearance?
Under AS/NZS 5601.1, when testing a consumer piping installation for soundness, the test pressure must be at least operating pressure or what minimum value, whichever is greater?
Leak Soundness Testing
Which instrument is most appropriate for measuring the low operating pressure of a domestic gas appliance during commissioning?
Gas Pressures Sizing
An installation pipe-sizing calculation must ensure that the pressure drop from the meter/regulator to the most remote appliance does not exceed what is permitted. The principal reason for limiting pressure drop is to ensure:
When sizing consumer piping, the gas consumption of each appliance is expressed in which unit so it can be totalled for the installation?
A flueless gas appliance (such as an unflued space heater) discharges its combustion products into the room. AS/NZS 5601.1 controls this hazard primarily by requiring:
Flueing Ventilation
Ventilation openings provided for a flued gas appliance installed in a confined space are required mainly to:
A flue terminal for a natural-draught flued appliance must be located so that combustion products disperse safely. Which of the following is a correct general principle from AS/NZS 5601.1?
What document must a registered gasfitter issue under the Gas (Safety and Measurement) Regulations 2010 to record that gasfitting work has been completed safely and complies with the regulations?
Nz Gas Regulations Certification
Which body registers and licenses gasfitters in New Zealand and administers the certifying gasfitter examination?
Pgdb Act Regulations
Under the Plumbers, Gasfitters, and Drainlayers Act 2006, what is the key difference between an authorised (certifying) gasfitter and a tradesperson gasfitter?
An odorant such as ethyl mercaptan is added to natural gas and LP Gas primarily to:
When commissioning a new gas appliance, in what order should the following key steps generally be carried out?
Purging of consumer piping before placing an installation into service is carried out to:
A 'room-sealed' (balanced flue) appliance is characterised by which feature?
Which gas property describes the energy released when a unit volume of gas is completely burned, used to calculate appliance gas rate from MJ/h?
The Wobbe index of a fuel gas is used principally to determine:
Question · Hard
When converting an appliance from natural gas to LP Gas, the most critical component change is usually the:
What is the approximate gross calorific value of natural gas as supplied in New Zealand?
Approximately what is the gross calorific value of propane (LP Gas)?
LP Gas is stored in cylinders as a liquid under pressure. What happens as gas is drawn off in vapour from a cylinder?
A typical first-stage regulator on an LP Gas cylinder installation reduces cylinder pressure to an intermediate pressure before the second-stage regulator delivers appliance pressure. The principal purpose of the second-stage regulator is to:
The standard nominal appliance operating (inlet) pressure for natural gas appliances in New Zealand is approximately:
The nominal appliance operating pressure for LP Gas appliances is approximately:
Which class of pipe material is commonly permitted by AS/NZS 5601.1 for above-ground consumer gas piping inside a building?
When a gas leak is suspected on an in-service installation, which detection method is acceptable under safe-working practice?
An open-flued (natural draught) appliance relies on which principle to draw combustion products up the flue?
A spillage (or flue-spillage) test on an open-flued appliance is carried out to confirm that:
Worst-case spillage testing of an open-flued appliance generally requires that during the test all mechanical extract fans and exhaust systems in the space are:
High-pressure gas work and certain higher-risk gasfitting in New Zealand is classified as 'high-risk gasfitting work.' What is required when this work is completed?
Which authority is the primary regulator for gas safety (including the gas appliance certification regime) in New Zealand?
Before disconnecting or working on an existing gas installation, the first safety action a gasfitter should take is to:
An appliance pressure test point (test nipple) is provided so the gasfitter can:
If a soundness (pressure) test shows a steady pressure drop over the test period, the correct action is to:
A continuous (always-burning) pilot light versus an electronic ignition system: which statement is correct regarding modern appliance safety?
A flame-failure device (FFD) on a gas appliance functions to:
Stoichiometric combustion of one volume of propane requires approximately how many volumes of air?
Stoichiometric combustion of one volume of methane (natural gas) requires approximately how many volumes of air?
When a gasfitter completes work and issues a Certificate of Compliance, the regulations require the certificate to be:
Which of the following best describes 'aeration' in a gas burner?
Flame 'lifting' (the flame lifting off the burner ports) is most commonly caused by:
Loading more…