Which New Zealand legislation sets out the primary safety requirements for electrical installations, appliances, and the carrying out of prescribed electrical work?
Electricity Safety Regulations 2010
Question · Easy
Under the Electricity (Safety) Regulations 2010, what term is used for work described in Schedule 1 clause 1 that is not excluded by clause 2?
Prescribed Electrical Work
Abbreviation used for the 2010 instrument whose amended version took effect on 13 November 2025.
Regulations and licensing
Guess the Term
Introduction & Exam Overview
1.1 Current Exam Facts
Study guide
Which New Zealand body sets the registration and competence requirements for electrical workers and appoints the Registrar of Electrical Workers?
Read the clue and guess the term in 6 tries.
Game
Under regulation 65, which document is required for general or high-risk PEW on an installation that installs or maintains its conductors or connected fittings?
Certification Coc Esc Roi
Legally defined tasks such as installing, maintaining or testing fittings and installations that only an authorised person may do.
What is the primary purpose of an Electrical Safety Certificate (ESC) as distinct from a Certificate of Compliance (CoC)?
Question · Medium
When is a Record of Inspection (RoI) required under the Electricity (Safety) Regulations 2010?
New Zealand organisation that issues practising licences to people who install, maintain and test wiring.
1.2 Open-Reference Strategy & Permitted Materials
Apart from the express exceptions, what system of supply does regulation 27 require for an installation designed and constructed to operate at standard low voltage in New Zealand?
Asnzs 3000 Wiring Rules
Swap tiles to line up three of the same term.
Term Match
An ordinary low-voltage installation is supplied from a MEN system. Which switchboard must be a MEN switchboard under regulation 27(4)?
Category of prescribed electrical work, defined in Regulation 6A, that covers mains work, PV systems, medical and hazardous work and requires inspection.
Risk categories
Per AS/NZS 3000, what is the maximum rated residual current for an RCD relied upon for additional protection against electric shock?
Under regulation 24(6), a 10 mA RCD required to protect children from direct contact is tested at five times its rated residual current. Within what time must it interrupt the current in all live conductors?
Testing Verification
Question · Hard
Category of prescribed electrical work for replacing a light switch or power outlet to repair an existing installation, for which inspection is not required.
1.3 Electrician Registration Pathway & Limits of Work
What is the standard DC test voltage used for an insulation resistance test on a typical 230/400 V low-voltage installation?
Flip two cards at a time to find matching terms.
Term Pairs
What is the usual minimum insulation resistance for a standard low-voltage final subcircuit tested at 500 V DC, with no equipment subject to a different limit?
New Zealand's public 230 V supply arrangement, in which the protective conductor is joined to the supply's return conductor and to an electrode.
Wiring and protection
Which sequence best represents the correct order of verification tests on a new installation under AS/NZS 3000?
What is the purpose of measuring earth fault loop impedance (Zs) during verification of a final subcircuit?
The general mass of the ground that conductive parts are connected to for safety.
1.4 Which Editions Apply: ESR Schedule 2 & the 13 November 2025 Update
An electrician proves a voltage indicator on a known source, checks for absence of voltage on an isolated circuit, then checks the indicator again. What is this procedure called?
Safe Isolation Safety
Find five hidden terms in a grid of letters.
Term Search
What is the essential first action when establishing safe isolation of a circuit, after identifying the correct point of isolation?
Enclosed air-break switch rated at no more than 125 A that opens automatically on overcurrent and can be reset.
NZECP 34 (the New Zealand Electrical Code of Practice for Electrical Safe Distances) primarily sets minimum requirements for what?
Electrical Codes Of Practice
NZECP 51 sets out the requirements for which type of work?
Protective device that opens a circuit by melting a wire element when excessive current flows.
Electricity Act & EWRB Framework
2.1 Electricity Act 1992 Framework
Which Standard provides the in-service safety inspection and testing requirements for portable electrical appliances and cords (PAT / 'test and tag') in New Zealand?
Installation Requirements
Trades Exam Prep Podcast
Listen on Spotify
Podcast
Which companion standard gives cable current ratings and voltage-drop data for typical New Zealand installation conditions?
Safety unit that opens a supply when leakage to the ground exceeds a predetermined level, such as 30 mA for a portable model.
Testing and verification
A standard-low-voltage installation follows a certified Part 1 design. Under regulation 61(4), what is the maximum voltage drop at maximum load from the point of supply to a socket-outlet or the supply terminals of a fixed-wired appliance?
What is the nominal single-phase low-voltage supply voltage and frequency in New Zealand?
Word that completes the standard term 'earth fault ___ impedance', meaning the complete circuit followed by fault current back to the supply and measured in ohms.
2.2 EWRB Role, Register & Registration Classes
What is the maximum rated residual current for an RCD providing additional shock protection on a new ordinary domestic socket-outlet or lighting final subcircuit?
For new installation wiring designed to AS/NZS 3000:2018 including Amendments 1, 2, and 3, subject to New Zealand modifications, which insulation colour does Table 3.4 specify for a protective earthing conductor?
Document required by regulation 65 for all general-risk and high-risk jobs before the job can be treated as complete.
Certification documents
Under regulation 13(1), what must a person ensure when carrying out work on only part of an electrical installation?
Loading more…