What are Mesterbrevnemnda's application fee and annual fee for a mesterbrev in 2026?
Business Management
Question · Easy
A ventilation firm gives notice to a 56-year-old technician who has worked there for 12 years. What is the minimum notice under arbeidsmiljøloven § 15-3?
Question · Medium
Under arbeidsmiljøloven § 10-9, what breaks must a technician have on an eight-hour working day?
Trades Exam Prep Podcast
Listen on Spotify
Podcast
What does internkontrollforskriften require of a ventilation contractor?
Which body awards the mesterbrev in Norway?
Under arbeidsmiljøloven § 10-6 (1), when may a ventilation firm use overtime?
A ventilation firm is to install and service heat pump coils that contain fluorinated refrigerants (F-gases). What do the rules require?
Faglig Fordypning Ventilasjonsteknikk
A 3.5-tonne air handling unit is to be lifted onto a roof by mobile crane. What should be done before the lift?
Faglig Ledelse Byggfag
What is the difference between selvkost and salgspris for a ventilation job?
Why must social costs (sosiale kostnader) be added to the hourly wage when pricing a technician's time?
A service technician has 1,750 paid hours a year, of which 1,400 can be billed. What is the billing rate (faktureringsgrad)?
A filter bank costs the firm NOK 10,000 and is sold with a 25 % markup. What are the sales price and the dekningsgrad?
Under NS 8405, the main contractor's delays stop the ventilation work. What must the ventilation contractor do to keep its right to more time?
A firm sells a ventilation unit to a consumer without installing it. Which law applies, and what is the longest reklamasjon limit?
When is NS 8406 a better choice than NS 8405 for a ventilation contract?
In a totalentreprise under NS 8407, who answers for the ventilation design?
Which Norwegian standard describes the process for integrated technical building installations (ITB), from design to commissioning and handover?
A ventilation subcontractor invoices a Norwegian main contractor for installation work. Does a domestic reverse-charge rule apply?
A ventilation firm runs short of cash despite a profitable order book. What is the most likely cause?
A provider fails to warn a consumer that a repair is not worth doing (håndverkertjenesteloven § 7), and the consumer would not have ordered it. What does § 8 say about payment?
Question · Hard
Under NS 8405, what can happen to a disputed claim that the contractor leaves out of its final account (sluttoppstilling)?
An apprentice reports internally that technicians are faking air-balancing reports. What protection does arbeidsmiljøloven chapter 2 A give?
Under byggherreforskriften, what applies to a ventilation contractor working on a large site?
Under NS 8405, the client orders a main duct rerouted around a new beam. The contractor disputes whether it is a change. What must it do?
During refurbishment, old duct insulation containing asbestos is found. What must the master do?
A duct workshop has fixed costs of NOK 1,800,000 and an average dekningsgrad of 45 %. What is its break-even turnover?
What does NS 3420-V cover?
A main contractor's insulation subcontractor uses unsuitable insulation, causing condensation damage. Who answers to the client?
What should a life-cycle cost (LCC) analysis under NS 3454 show a client choosing between two ventilation concepts?
How can a ventilation firm best combine its quality system (KS) with statutory internal control (HMS)?
Under SAK10 § 9-3, what decides the tiltaksklasse of a building work?
What is the purpose of independent control (uavhengig kontroll) under SAK10 chapter 14?
What does TEK17 § 13-1 require of ventilation?
Under TEK17 § 13-3, how is the minimum fresh air for an office in use found?
Under TEK17 § 13-3 (2), what minimum fresh air is required for material emissions in an office when it is not in use?
What does TEK17 § 13-4 (2) require for rooms for permanent stay?
How is specific fan power (SFP) defined?
Where in TEK17 is an SFP of at most 1.5 kW/(m³/s) stated?
What annual average heat recovery efficiency does the energy measures table in TEK17 § 14-2 (2) give for homes?
In a bill of quantities, what is the main use of NS 3420-V items?
Which CO₂ level does Arbeidstilsynet's guidance on indoor climate use as a norm for adequate ventilation in workplaces?
What do categories I, II and III in NS-EN 16798-1 express?
How does NS-EN 16798-3 classify outdoor air?
Under NS-EN 16798-3, what restriction applies to extract air in classes ETA 3 and ETA 4?
How is total pressure related to static and dynamic pressure in a duct?
What is an advantage of a rotary heat exchanger compared with a plate exchanger?
What prevents extract air from leaking into the supply air in a rotary heat exchanger?