Mesterbrevloven § 1 protects the title mester. Who may use the title malermester in marketing?
Business Management
Question · Easy
Under arbeidsmiljøloven § 6-1, when must a painting firm have a verneombud (safety representative)?
Under arbeidsmiljøloven § 7-1, when must a painting firm set up an arbeidsmiljøutvalg (AMU)?
Trades Exam Prep Podcast
Listen on Spotify
Podcast
Internkontrollforskriften § 5 lists eight points for systematic HSE work. Which of them must a painting firm document in writing?
Question · Medium
A painting firm is to coat a floor with a solvent-borne epoxy in a poorly ventilated room. What must the employer consider first under the chemical rules in arbeidsmiljøloven and forskrift om utførelse av arbeid?
In a painting company organised as an aksjeselskap (AS), how does aksjeloven divide responsibility between the board (styret) and the daglig leder?
Under arbeidsmiljøloven §§ 10-4 and 10-6, what are the general limit for normal working hours and the minimum overtime supplement?
Under arbeidsmiljøloven §§ 15-3 and 15-6, how long may an agreed prøvetid last, and what notice applies during it unless otherwise agreed?
A painting master wants to take on apprentices (lærlinger) in malerfaget. What must the firm have under opplæringslova?
When a painting firm calculates the hourly selvkost for a journeyman, what must be added to the direct wage?
A painting job has materials of NOK 40,000, labour of NOK 60,000 and social costs of NOK 24,000. Indirect costs are 20 % of the sum of these. What is the selvkost?
Question · Hard
What is the difference between påslagsprosent (markup) and dekningsgrad (contribution margin ratio) in pricing painting work?
A facade of 360 m² gets two coats. Coverage is 8 m² per litre per coat, with 10 % waste. How many 10-litre buckets must be ordered?
Faglig Fordypning Maler
A painting firm has fixed costs of NOK 1,200,000 a year and an average dekningsgrad of 40 %. What is its break-even turnover (nullpunktsomsetning) excluding MVA?
A Norwegian painting firm invoices a Norwegian main contractor for painting work on a commercial building. How is MVA handled?
What is the main purpose of a liquidity budget (likviditetsbudsjett) for a growing painting firm?
How is working capital (arbeidskapital) defined in a painting firm's balance sheet?
Before signing a NOK 3 million painting contract with a new property developer, which risk measure is most sensible?
A painting firm paints and wallpapers rooms in a private homeowner's existing flat. Which law governs the contract?
Under håndverkertjenesteloven § 32, how far may a painter's final price exceed a prisoverslag (estimate) given to a consumer?
Under håndverkertjenesteloven § 22, what is the longest time a consumer has to complain (reklamere) about a defect in painting work on a house?
What is the main difference between NS 8405 and NS 8406?
A painting contractor under NS 8405 receives an oral order from the client's representative to fill unfinished joints before priming. The painter considers it extra work. What must the painter do to keep the right to extra payment?
If nothing else is agreed, how is dagmulkt for delay calculated under NS 8405?
At an overtakelsesforretning under NS 8405, some minor touch-up defects are noted in the painting work. What is the normal outcome?
In a public tender for painting a school, what is the difference between kvalifikasjonskrav and tildelingskriterier?
When may a painting firm use the mester title and Mestermerket in its marketing?
A customer complains that exterior paint is flaking one year after the job. How should the painting master handle it?
When a painting firm calculates a unit price per m² for filling and painting walls, what must the labour norm include?
A painting firm advertises a paint system as 'completely non-toxic and climate neutral'. What does markedsføringsloven require?
What does an enterprise confirm when it declares ansvarsrett (erklæring om ansvarsrett) in a building case?
Faglig Ledelse Byggfag
TEK17 § 13-9 says precipitation and air moisture must not enter and cause moisture damage or fungal growth. What does this mean for an exterior coating on a timber facade?
DiBK's guidance to TEK17 § 11-9 gives pre-accepted fire properties for surfaces. What class applies to wall and ceiling surfaces in an escape route (rømningsvei)?
A painted surface is planned inside the shower zone of a bathroom (TEK17 § 13-15). What is required?
Why do many projects specify low-emission paints, such as Svanemerket or M1-classified products?
What is sentral godkjenning for ansvarsrett under SAK10 chapter 13?
SAK10 § 14-2 makes independent control (uavhengig kontroll) mandatory for certain work regardless of tiltaksklasse. Which?
A painting firm with ansvarsrett finds a non-conformance (avvik) on site. What do its quality routines under SAK10 § 10-1 require?
Under SAK10 § 8-1, what must the søker confirm when applying for ferdigattest?
What is NS 3420-T used for in painting contracts?
Which aesthetic classes does the 2019 edition of NS 3420-T use for painted interior surfaces such as gypsum board?
A description calls for painted gypsum board to meet aesthetic class K3 under NS 3420-T. What does meeting this class depend on?
Under NS 3420-T, what is the highest aesthetic class for painted perforated gypsum boards or boards with a visible V-groove?
Table T2 in NS 3420-T sets appearance requirements for opaque interior paint on gypsum, concrete and plaster. For which gloss levels does it apply in the 2019 edition?
Under NS 3420-T (2019), who must choose the aesthetic class for a painted surface where the class is part of the description?
NS 3420-T (2019) clarified when the general tolerances in NS 3420-1 apply to painting work. Which statement is correct?
A client wants semi-gloss paint on large gypsum walls lit by grazing daylight from tall windows. What should the painting master advise?
Loading more…