Which component of the hemodialysis machine is responsible for detecting air bubbles in the venous blood line?
Dialysis Equipment
Question · Easy
The blood leak detector on a hemodialysis machine primarily uses which method to identify hemoglobin in the spent dialysate?
Question · Medium
Normal operating conductivity range for hemodialysis dialysate is approximately:
Nursing & Healthcare Exam Prep Podcast
Listen on Spotify
Podcast
A hemodialysis machine's conductivity alarm activates. The FIRST action a biomedical technician should take is:
Troubleshooting
In a bicarbonate proportioning system, the bicarbonate concentrate is typically delivered at what ratio with purified water?
Proportioning Systems
Question · Hard
Which proportioning system type measures the actual mass of concentrate dispensed rather than volume?
AAMI/ISO 13959 sets the maximum allowable chloramine level in hemodialysis water at:
Water Treatment
Carbon tank bed exhaustion in a water treatment system is BEST confirmed by testing for:
In a series carbon tank arrangement, sampling for chloramine breakthrough should occur:
Which parameter is used to verify reverse osmosis (RO) membrane performance in a hemodialysis water system?
According to AAMI standards, the maximum allowable bacteria count in hemodialysis water is:
A water softener in a hemodialysis water treatment system functions by:
The primary purpose of the multimedia filter (sediment filter) in a hemodialysis water treatment system is to:
Ultraviolet (UV) disinfection in the hemodialysis water distribution loop primarily inactivates microorganisms by:
Dead legs in a hemodialysis water distribution loop are problematic primarily because they:
The recommended maximum dead-leg length-to-diameter ratio in a hemodialysis water distribution loop is:
Which chemical is most commonly used for high-level disinfection of hemodialysis machine water pathways?
Disinfection
After chemical disinfection of a hemodialysis machine, the proper rinse verification method uses:
Peracetic acid (PAA) used for hemodialysis machine disinfection is preferred over bleach in some facilities primarily because:
Heat disinfection of a hemodialysis machine typically uses water at what temperature and duration?
Citric acid disinfection of a hemodialysis machine is MOST effective for removing:
During dialysis, arterial pressure (pre-pump) is typically:
A low arterial pressure alarm during hemodialysis most commonly indicates:
A high venous pressure alarm during hemodialysis is MOST likely caused by:
Ultrafiltration (UF) control in modern hemodialysis machines is primarily achieved by:
The transmembrane pressure (TMP) in hemodialysis represents:
A dialysis machine temperature alarm activates when dialysate temperature exceeds the upper limit. The safe operating range for dialysate temperature is approximately:
The dialysate circuit in a hemodialysis machine flows in what direction relative to blood flow through the dialyzer?
Deionization (DI) in a water treatment system removes:
A conductivity meter is used for water quality testing in dialysis. What does a decrease in product water conductivity after the RO membrane indicate?
Calibration
Which reference standard is used to verify calibration of a conductivity meter for dialysate quality testing?
Preventive maintenance (PM) frequency for dialysis machine conductivity cell cleaning is typically:
Preventive Maintenance
An annual preventive maintenance task specific to the RO system in dialysis water treatment includes:
Electrical safety testing of a hemodialysis machine measures chassis leakage current. The maximum allowable chassis leakage current per NFPA 99 for patient-care equipment is:
Electrical Safety
A ground fault circuit interrupter (GFCI) protects against electrical shock by:
Renalin (peracetic acid/hydrogen peroxide mixture) was historically used in dialyzer reuse programs primarily for:
Dialyzer Reuse
In dialyzer reuse, total cell volume (TCV) testing verifies:
OSHA's Bloodborne Pathogen Standard (29 CFR 1910.1030) requires that dialysis technicians working with blood or OPIM (other potentially infectious materials) must:
Safety
Mercury-containing sphygmomanometers and thermometers in dialysis facilities are being phased out primarily because:
Environmental
CMS Conditions for Coverage require dialysis facilities to have a Quality Assessment and Performance Improvement (QAPI) program that includes biomedical equipment. This means:
Regulatory
Hemodialysis machines are classified by the FDA as:
Biomedical asset documentation for a dialysis machine should include at minimum:
Documentation
When a hemodialysis machine's air detector alarm activates during treatment, the correct immediate response is:
The heparin pump on a hemodialysis machine delivers anticoagulant into the blood circuit. The typical delivery site is:
Calibration of a dialysis machine's temperature monitor should be verified using:
In a volumetric UF balancing chamber system, the function of the balancing chamber is to:
A dialysis water system produces water with a hardness of 8 grains per gallon after the softener. This indicates: