Which ASTM standard defines the standard terminology used for soil and rock in the NICET Geotechnical program?
Nicet Geotech General
Question · Easy
Never enter a tank before testing the air
Short
Which ASTM standard specifies the laboratory determination of moisture (water) content of soil?
Per ASTM D4220, why are undisturbed cohesive samples typically sealed with wax and kept upright during transport?
Question · Medium
Trades Exam Prep Podcast
Listen on Spotify
Podcast
Under OSHA 29 CFR 1926 Subpart P, which soil type is the most stable for excavation purposes?
At what excavation depth does OSHA generally require a protective system such as sloping, shoring, or shielding?
A soil sample has a wet mass of 180.0 g and a dry mass of 150.0 g. What is the water content?
For a saturated soil, which weight-volume equation is correct?
In ASTM D653 terminology, what is 'liquid limit' (LL)?
Why should a field technician never alter raw test data on an original field log, even if a reading appears wrong?
A confined-space permit-required entry must include atmospheric testing for all of the following EXCEPT:
Convert 2.35 g/cm^3 to pounds per cubic foot (pcf). Use 1 g/cm^3 = 62.43 pcf.
At a drilling site, the minimum standard PPE ensemble for a geotechnical field technician typically includes:
A 1-inch diameter Shelby tube has a cross-sectional area of approximately:
You observe a subcontractor compacting wet fill that pumps under the roller. What is the correct first action?
What does the term 'plasticity index' (PI) represent?
A sample weighs 500 g and 62 g pass the No. 200 sieve. What is the fines content?
When preparing a daily field report for a drilling operation, which item is LEAST essential?
Which gas is produced when calcium carbonate in soil reacts with dilute hydrochloric acid, a common field test for calcareous soils?
For an excavation 22 feet deep in Type B soil, OSHA 1926.652 requires:
Question · Hard
A contractor asks you to ignore one failing density test because 'the next two will pass.' What is the correct response?
In the Standard Penetration Test (ASTM D1586), the N-value is the number of hammer blows required to drive the sampler:
Nicet Geotech Exploration
Per ASTM D1586, the standard SPT hammer weighs and falls:
When drilling below the water table in cohesionless soil, why is the borehole typically kept filled with drilling fluid or water at or above the water table elevation?
A Shelby tube (ASTM D1587) is typically used to recover:
A Shelby tube sample is pushed into soft clay using hydraulic pressure rather than driven with a hammer because:
On a boring log, a symbol of an inverted triangle over a horizontal line typically indicates:
Why should groundwater readings be recorded both during drilling and after a stabilization period (often 24 hours)?
Rock Quality Designation (RQD) is computed as:
Hollow-stem augers are often preferred over solid-stem augers in granular soils because:
During rotary wash boring, the mud 'cake' built up on the borehole wall serves what purpose?
In a groundwater monitoring well, the annular seal above the screened interval is typically:
An SPT blow count is recorded as 50 blows for 4 inches, then refusal. The N-value is typically reported as:
On a boring location plan, what do station and offset coordinates represent?
When logging a boring, a technician should describe soil using:
Before drilling on a new site, federal law (47 CFR and state one-call regulations) requires:
A split-spoon sampler used in SPT has an outside diameter and an inside diameter of approximately:
A pocket penetrometer is typically used to estimate:
During diamond coring, if core recovery is low (<50 percent) in fractured rock, the technician should:
Recovery ratio for a Shelby tube sample is computed as:
To obtain an undisturbed sample of cohesionless sand below the water table, which specialized method is often used?
Per ASTM D6938, the nuclear density gauge measures in-place wet density by:
Nicet Geotech Construction
The sand cone test (ASTM D1556) determines in-place density by:
The Standard Proctor test (ASTM D698) uses a 5.5-lb hammer dropped from 12 inches in how many layers and blows per layer for the 4-inch mold?
Modified Proctor (ASTM D1557) imparts more energy than Standard Proctor (D698) and therefore typically yields:
If in-place dry density is 115.0 pcf and Standard Proctor maximum dry density is 120.0 pcf, the relative compaction is:
The line of zero air voids (ZAV) on a compaction curve represents:
Loading more…