Which NFPA 72 (2022) chapter covers the requirements for protected premises fire alarm systems?
Nicet Fire Alarm Ii Installation
Question · Easy
What should a Level II technician resolve before turning a field condition into a work plan?
Installation
Flashcard
Per NFPA 72 (2022), what is the minimum required secondary (standby) power capacity for a typical protected premises fire alarm system in non-voice service?
Nicet Fire Alarm Ii Layout
Question · Medium
Panel that receives signals from initiating devices and determines the required output functions.
System installation
Guess the Term
Exam Overview & Open-Book Strategy
1.1 Exam Facts, Eligibility & Logistics
Study guide
Cheat sheet
Under the NFPA 72 (2022) battery-sizing rule, what multiplier is applied to the calculated amp-hour demand?
Read the clue and guess the term in 6 tries.
Game
How do a circuit, pathway, and raceway differ?
Per NFPA 72 (2022) Chapter 23, which pathway class will continue to operate after a single open in the circuit?
Addressable pathway used for communication between devices.
T-tap branches off a signaling line circuit are generally permitted only on which pathway class?
Why do listed equipment instructions matter during installation?
Which NFPA 72 (2022) chapter contains the circuit and pathway survivability requirements?
Conventional pathway used to connect non-addressable detectors and manual stations to an addressable loop.
1.2 Open-Book References & On-Screen Navigation
Per NFPA 72 (2022) Chapter 12, which pathway survivability level is achieved by routing circuits through a building protected throughout by an approved automatic sprinkler system with circuits in metal raceway?
Question · Hard
Swap tiles to line up three of the same term.
Term Match
What functional distinction separates an IDC, SLC, and NAC?
Per NFPA 72 (2022) Chapter 24, partial evacuation and one-way emergency communication requirements apply to which type of system?
Nicet Fire Alarm Ii Complex Operations
Wiring path that supplies power to horns, strobes, and other warning devices.
What is the primary purpose of elevator Phase I emergency recall?
What must be verified when adding an addressable device?
Which detector typically initiates elevator hoistway/machine-room shunt trip for sprinklers?
Visual notification appliance with a xenon flash tube or LED whose light output is rated in candela.
1.3 Certification Path & Performance Measures
Per NFPA 72 (2022) Section 17.7.5, duct smoke detectors used for HVAC shutdown are required to be installed in what location relative to the duct airflow?
Flip two cards at a time to find matching terms.
Term Pairs
What is the purpose of an end-of-line supervision component?
A sprinkler waterflow switch is most appropriately monitored as which signal type at the fire alarm control unit?
Trip arrangement that cuts elevator power when waterflow is detected in the machine room or shaft.
A valve tamper switch on a sprinkler post indicator valve is properly monitored as which signal type?
When is a branch or T-tap acceptable on a fire alarm pathway?
Per NEC Article 760, Power-Limited Fire Alarm (PLFA) circuits must be separated from Class 1, light, and power conductors in the same enclosure or raceway unless which condition is met?
Component installed on fire alarm wiring to limit transient overvoltage.
Installation: Work Planning
2.1 Work Plans from Field Conditions
Which of the following is a typical difference between NPLFA and PLFA fire alarm circuits?
Find five hidden terms in a grid of letters.
Term Search
How is pathway class different from pathway survivability?
When calculating conduit fill for fire alarm cables per Chapter 9 of the NEC, what is the maximum permitted fill for a conduit containing more than two cables?
Voice-clarity score whose 0.5 value is considered equivalent to 0.7 on another common scale.
Per NFPA 72 (2022) Chapter 18, public-mode visible notification appliance candela ratings begin at what minimum candela rating for wall-mounted strobes?
Why must fire alarm conductors be separated from incompatible wiring?
Per NFPA 72 (2022), what minimum sound pressure level above average ambient is required for audible public-mode alarm signaling?
Switch that reports whether a sprinkler control valve has moved from its proper position.
System maintenance