What license does Massachusetts require for fire alarm system installation?
State Laws Regulations
Question · Easy
Which Massachusetts board oversees Systems Technician licensing?
How many hours of approved education are required for the Massachusetts Systems Technician Class D exam?
Trades Exam Prep Podcast
Listen on Spotify
Podcast
How many hours of practical experience does Massachusetts require for the Systems Technician Class D license?
Under whom must a Massachusetts Systems Technician trainee work to accumulate experience hours?
The Massachusetts Systems Technician Class D exam covers which of the following?
Question · Medium
Which code editions does the Massachusetts Systems Technician exam reference as of 2026?
Massachusetts requires Systems Technician work experience to be a minimum of how many years?
In Massachusetts, the Systems Technician Class D license permits work on which systems?
What is the consequence of performing fire alarm installation without a Systems Technician license in Massachusetts?
Per NFPA 72, what is the standard spacing for spot-type smoke detectors on a smooth ceiling?
Nfpa Codes
What minimum sound level is required for notification appliances in sleeping areas per NFPA 72?
Under NEC Article 760, fire alarm circuits are specifically covered under which article?
What is the minimum battery standby time for a fire alarm system without a generator per NFPA 72?
System Design
Per NFPA 72, what is the maximum travel distance to a manual pull station?
Installation Practices
What is the required mounting height for manual pull stations per NFPA 72?
What type of circuit provides redundant pathways for continued operation after a single open fault?
What is the primary function of an end-of-line resistor?
Per NFPA 72, trouble conditions must be indicated within how many seconds?
What cable type is required for fire alarm installations in plenum spaces?
Per NFPA 72, visible notification appliances must flash at what color?
What is the required temporal pattern for fire alarm evacuation signals?
Per NFPA 72, what derating factor applies to sealed lead-acid batteries?
Question · Hard
What signal does a ground fault generate on a fire alarm circuit?
Per NEC Article 760, what is the minimum conductor size for NPLFA circuits?
What is the standard fixed-temperature rating for ordinary heat detectors?
Per NFPA 72, smoke detector sensitivity testing must occur at what interval?
Inspection Testing
What is the maximum notification appliance activation time after alarm per NFPA 72?
What type of fire alarm system assigns unique addresses to each device?
Per NFPA 72, what documentation must be provided after system installation?
What is the minimum distance from an air supply diffuser for smoke detectors per NFPA 72?
What must happen when a fire alarm system impairment exceeds 4 hours?
Per NFPA 72, what is the maximum conduit fill for three or more conductors?
Per NFPA 72, elevator recall requires smoke detectors at which locations?
What is the proper method for testing a manual pull station annually?
What is the purpose of fire alarm system acceptance testing?
What type of detector is most responsive to slow smoldering fires?
What device monitors sprinkler valve position?
Per NFPA 72, fire alarm circuit breakers must have what special feature?
Per NFPA 72, what is the minimum visible appliance candela for a 20x20 ft room?
What fire alarm wiring penetration through a fire-rated wall requires?
Per NFPA 72, how often must batteries be load tested?
What is the purpose of a monitor module in an addressable system?
What is the sidewall mounting range for smoke detectors per NFPA 72?
Per NFPA 72, what is the central station alarm retransmission time?
What is the minimum visible appliance mounting height per NFPA 72?
Per NFPA 72, what is the required signaling for AC power failure?