What is the primary well barrier when drilling a well?
Principles And Procedures
Question · Easy
The hydrostatic pressure of a fluid column depends on which two factors?
Unplanned influx of formation fluid or gas into the wellbore that, without corrective action, can lead to a blowout.
Influx detection
Guess the Term
Exam Overview
Well Control Incidents and Their Consequences
Study guide
A well has a mud weight of 12.0 ppg and a true vertical depth of 10,000 ft. What is the approximate hydrostatic pressure at the bottom of the hole?
Calculations And Kill Sheet
Question · Medium
Read the clue and guess the term in 6 tries.
Game
Which of the following is a recognised warning sign of a kick while drilling?
Greatest reading at the wellhead that the space around the pipe can hold without compromising any part of it.
Wellbore strength
A 'drilling break' is best described as:
When a flow check is positive after a drilling break, what is the correct first action for the driller?
Procedure that shows rock can hold a set pressure without starting a crack.
Qualification, Assessment and Study Planning
What does SIDPP stand for in well control?
Swap tiles to line up three of the same term.
Term Match
After shutting in a well, why is the Shut-In Casing Pressure (SICP) usually higher than the Shut-In Drill Pipe Pressure (SIDPP)?
Procedure that finds the pressure needed to start a crack in exposed rock.
A well is shut in with SIDPP of 300 psi. The current mud weight is 11.0 ppg and the TVD is 9,000 ft. What is the required kill mud weight?
In the Driller's Method of well control, how many circulations are required to kill the well?
Gauge value that, when added to the kill-rate pump reading, equals the reading at the start of a kill.
Gauge readings
Hydrostatic Pressure and the Circulating System
Hydrostatic Pressure, Fluid Gradients, and Mud Weight
Which statement best describes the Wait and Weight (Engineer's) Method?
Flip two cards at a time to find matching terms.
Term Pairs
During a kill operation, the drill pipe pressure is the control parameter because:
Gauge value found by adding the kill-rate pump reading to the closed-in string reading.
Kill methods
What is MAASP?
As gas in a kick migrates up a shut-in well without being allowed to expand, what happens to the pressure throughout the well?
Question · Hard
Gauge value seen once the fluid that will kill the well reaches the bit.
Multiple Fluid Columns and Inverse Hydrostatic Calculations
Which type of influx is generally the most hazardous to manage in a well control situation?
Find five hidden terms in a grid of letters.
Term Search
What is the main purpose of a leak-off test (LOT)?
Downhole mud weight while pumping, made from the static column plus annulus friction.
Hydraulics
Why is a slow circulating rate (SCR) pressure recorded during well operations?
The difference between a 'soft' shut-in and a 'hard' shut-in is mainly that:
Casing ___: reinforced sub at the bottom of the string that guides it past irregularities in the open hole.
Well construction
U-Tube Principle, Dynamic Pressure Losses, and Equivalent Circulating Density
Formation pore pressure that is higher than the normal hydrostatic gradient for the area is described as:
Which of the following is a common cause of a kick?
Casing string hung inside an earlier one and stopping short of the wellhead.
Swabbing during a trip out of the hole tends to:
What is the purpose of a trip sheet during tripping operations?
___ and weight: one-circulation kill method delayed while heavier fluid is mixed.
Formation Pressure and Integrity Limits
Formation Pore Pressure, Normal vs Abnormal Pressure, and Fracture Gradient
During a well kill using the Driller's Method, the casing pressure is held constant during the FIRST circulation by adjusting the:
What does ICP stand for, and when is it used?
Solid additive put into mud to stop it escaping into a reservoir so a heavy column stays in place.
Contingency response
A pump delivers 0.1 barrels per stroke. How many strokes are needed to pump 250 barrels of kill mud to the bit?
Final Circulating Pressure (FCP) is generally: