Which fire extinguisher type is most appropriate for an electrical panel fire where the power cannot be immediately isolated?
Workshop Safety
Question · Medium
Under typical ITI workshop OSH practice, a yellow-and-black striped floor marking indicates:
Before working on a motor terminal box, the first electrical safety step is to:
Trades Exam Prep Podcast
Listen on Spotify
Podcast
Used transformer oil contaminated with unknown chemistry in an NSTI workshop should be:
Question · Easy
The purpose of a residual current device (RCCB/ELCB) in a workshop DB is to:
5S housekeeping in an electrical workshop places frequently used testers:
First aid for a conscious electric-shock victim requires:
Question · Hard
According to Ohm's law, if voltage across a resistor is 230 V and resistance is 46 Ω, the current is:
Electrical Fundamentals
Two 100 Ω resistors in parallel have an equivalent resistance of:
The unit of electrical power in SI is:
In a purely resistive AC circuit at unity power factor, the phase angle between voltage and current is:
A 3 kW heater on 230 V single-phase draws approximately:
The colour code for neutral conductor in new Indian wiring practice is typically:
Magnetic flux density is measured in:
Skin effect in AC conductors causes:
A capacitor blocks:
A megger is primarily used to measure:
Measuring Instruments
When using a clamp meter on a single-core cable carrying AC load current, the reading is valid if:
A multimeter on ohms range must be:
Wattmeter connection in a single-phase circuit requires:
A tong tester (clamp-on) measures current by detecting:
Calibration of an analog ammeter checks:
Earthing of electrical equipment primarily provides:
Wiring Earthing
IS/IEC-style earth electrode resistance for domestic installations is aimed to be:
PVC insulated copper cable marked 1.5 mm² is typically used for:
A ceiling rose in domestic wiring connects:
Looping-in method in domestic wiring means:
Earth continuity test on an installation checks:
Mineral-insulated copper-sheathed (MICC) cable is chosen where:
Lead-acid battery specific gravity about 1.280 (at ~25°C) in each cell typically indicates:
Batteries Solar
Connecting two 12 V, 100 Ah batteries in series gives:
A solar PV module's open-circuit voltage (Voc) is measured with:
Illuminance of 500 lux on a workbench means:
Illumination
A fluorescent tube requires a ballast/starter (or electronic driver) to:
Glare in workshop lighting is reduced by:
In a domestic iron, the thermostat controls:
Domestic Appliances
A washing machine universal motor runs on:
Refrigerator compressor not starting but hums may indicate:
ELCB tripping when turning on a geyser may be due to:
Interpoles in a DC machine are placed to:
Dc Machines
A DC shunt motor has:
Reversing rotation of a DC shunt motor (constant field) is done by:
Back EMF in a running DC motor:
A DC series motor should not be started on no load because:
Three-point starter for DC shunt motor protects against:
Synchronous speed of a 4-pole, 50 Hz induction motor is:
Ac Motors
Slip of an induction motor is defined as:
Loading more…