In the standard Irish single-phase domestic supply, what is the nominal voltage between line and neutral?
Electrical Theory Circuits
Question · Easy
What is the frequency of the Irish AC mains supply?
A 3 kW immersion heater operates from a 230 V supply. What current does it draw?
Trades Exam Prep Podcast
Listen on Spotify
Podcast
Three 30 ohm resistors are connected in parallel. What is the total resistance of the combination?
In a purely inductive AC circuit, the current waveform relative to the voltage waveform is:
Question · Medium
A load draws 10 A at 230 V with a power factor of 0.8 lagging. What is the true power consumed?
What is the peak value of a 230 V RMS sinusoidal supply?
A conductor carries 5 A for 4 minutes. How much charge passes a point in the conductor?
Which quantity is measured in siemens?
The resistance of a copper conductor will increase if you:
Two capacitors of 4 microfarad and 12 microfarad are connected in series. What is the total capacitance?
Kirchhoff's current law states that at any junction in a circuit:
In a balanced three-phase star (wye) connected system, the relationship between line voltage and phase voltage is:
Question · Hard
What does I.S. 10101:2020 represent in Ireland?
National Wiring Rules
Which standard did I.S. 10101:2020 replace as Ireland's national wiring rules?
Under the EU-harmonised colour code used in I.S. 10101, the line conductor of a single-phase circuit is which colour?
Under I.S. 10101, socket-outlet circuits intended for general use must be protected by an RCD with a rated residual operating current not exceeding:
A notable change introduced by I.S. 10101 compared with ET 101 is that RCD protection is now required for:
In a TN system under I.S. 10101, the maximum disconnection time for a 230 V final circuit supplying socket-outlets up to 63 A is:
Which earthing system has the supply neutral and protective earth combined in part of the network and separated within the installation?
The main protective bonding conductor connects the main earthing terminal to:
Within the zones of a domestic bathroom, the requirement that most influences accessory and equipment selection is based primarily on:
An IP rating of IP65 indicates that the enclosure is:
Voltage drop in a final circuit is generally limited so that equipment operates correctly. For lighting circuits the commonly applied limit is approximately:
Wiring Systems Installation
When selecting the cross-sectional area of a cable, the current-carrying capacity must be derated for several factors. Which of the following reduces a cable's current-carrying capacity?
A common wiring method for fixed installations in Irish dwellings uses flat twin-and-earth cable. The earth (protective) core in this cable is normally:
Which wiring system uses a continuous metal sheath that itself can serve as the circuit protective conductor and offers excellent fire survival?
When PVC-insulated cables are run in a metal conduit, a key reason for ensuring the conduit is mechanically and electrically continuous is to:
Cables buried directly in a wall at less than 50 mm depth, outside a recognised safe zone, must be:
A radial circuit differs from a ring final circuit in that a radial circuit:
The main purpose of installing cable trunking with a removable lid in a commercial installation is to:
Steel-wire-armoured (SWA) cable is frequently chosen for underground supplies to outbuildings mainly because the armour provides:
A discrimination (selectivity) problem in a distribution board would be evident if:
A Type B miniature circuit breaker (MCB) is designed to trip on overload and to operate magnetically at a fault current of approximately:
The first dead test in the recommended testing sequence for a new installation is normally:
Inspection Testing
What is the minimum acceptable insulation resistance value for a 230/400 V installation, tested at 500 V DC?
Insulation resistance testing of a final circuit is most commonly carried out using a test voltage of:
A polarity test on a lighting circuit is carried out to confirm that:
Earth-fault loop impedance (Zs) is measured to verify that:
When testing a 30 mA RCD used for additional protection, applying a test current of 5 times the rated residual current (150 mA) should cause the device to trip within:
Before carrying out an insulation resistance test on a circuit containing electronic equipment, the electrician should:
A certificate completed after testing a new installation in Ireland confirming compliance with I.S. 10101 is best described as a:
The synchronous speed of a 4-pole three-phase induction motor on a 50 Hz supply is:
Machines Motors
The main reason a star-delta starter is used on a large three-phase induction motor is to:
Slip in a three-phase induction motor is best defined as:
To reverse the direction of rotation of a three-phase induction motor you should:
A single-phase transformer has 400 primary turns and 100 secondary turns. If the primary voltage is 230 V, the secondary voltage is approximately:
Loading more…