In a half-brick thick wall built in stretcher bond, what is the typical overlap of one brick over the course below?
Brick Block Bonding
Question · Easy
Which bond consists of alternate courses made up entirely of headers and entirely of stretchers?
In Flemish bond, how are headers and stretchers arranged within each course?
Trades Exam Prep Podcast
Listen on Spotify
Podcast
A brick cut across its width to about three-quarters of its length, used to start a course and maintain the lap, is called a:
Question · Medium
The vertical mortar joint between the ends of two bricks in the same course is correctly called the:
What is the standard work (actual) size of a metric brick used in Ireland and the UK?
Using the standard gauge, how many courses of brickwork rise to a height of 300 mm?
Which closer is cut diagonally so that one end shows a half-header, and is used to maintain bond at a square reveal or jamb?
When laying a half-brick stretcher wall, where should the perpend joints of one course sit relative to the course below?
What is the main purpose of bonding bricks rather than building them as stacked columns?
A standard dense concrete block in Ireland commonly has a coordinating face size of:
When blockwork is built in stretcher bond, the perpends should be staggered so that there is at least a lap of:
In English garden wall bond, the header courses are usually placed:
Which face of a brick is the 'stretcher' face?
A 'broken bond' is created on a wall when:
The frog of a brick should normally be laid:
When raking out and pointing later, the depth of joint typically raked out before pointing is about:
Which jointing profile is generally the most weather-resistant for external facing brickwork in the Irish climate?
A brick laid flat across the top of a wall with its stretcher face exposed and its length running across the wall is in which position?
A course of bricks stood vertically on end above a window or door opening is called a:
Why must the two leaves of a cavity wall be kept separate by a clear cavity?
Cavity Walls
On a typical cavity wall, what is the usual maximum spacing of wall ties in the general field of the wall?
At a vertical edge such as a window reveal, wall ties should be placed within 150 mm of the opening at a maximum vertical spacing of:
How should a cavity wall tie be laid so it does not carry water across the cavity?
What is the purpose of weep holes in the outer leaf above a cavity tray or DPC over an opening?
A cavity tray placed above a lintel or where an abutment occurs is installed to:
What is the minimum height of a horizontal DPC above finished external ground level usually required to prevent rising damp and splashing?
Where a vertical DPC is used at a window or door reveal in a cavity wall, its purpose is to:
When building cavity walls, why must mortar droppings be kept off the wall ties and out of the cavity?
In partial-fill cavity wall construction, what is the usual minimum residual clear cavity left between the insulation board and the outer leaf?
What component is built into the cavity at the base of a wall, just above the DPC, to allow any water in the cavity to escape and to keep the cavity clear?
A chimney breast and flue built within a cavity wall must maintain which key safety dimension around the flue?
Question · Hard
When closing the cavity at the top of a wall (eaves or parapet), the main reason for using a cavity tray or closer is to:
Which test is the first step in accurately setting out the corners of a rectangular building on site?
Setting Out
Using the 3-4-5 rule, if one side of the right angle is set at 3 m and the other at 4 m, the diagonal (hypotenuse) should measure exactly:
Profile boards set up at the corners of a building are used to:
A datum peg on a building site is established to:
A gauge rod (storey rod) is used during bricklaying to:
When building a wall between two corners (quoins), the bricklayer keeps each course straight and level by:
To confirm a set-out rectangle is truly square after running the lines, the bricklayer should:
When setting out brickwork lengths to avoid awkward cuts, the bricklayer works in 'dry bonding'. This means:
For general external brickwork in Ireland's exposed, wet climate, a commonly specified mortar designation is (iii), with a cement:lime:sand ratio of approximately:
Mortars Materials
Why should bricklaying mortar normally be weaker than the bricks or blocks it bonds?
Adding hydrated lime (or a plasticiser) to a cement:sand mortar mainly improves its:
What is the usual nominal thickness of a bed joint in standard brickwork gauge?
Sand used for bricklaying mortar should be:
In cold weather, bricklaying should normally stop when the air temperature falls and is not rising above:
Loading more…