Under RGII rules, how often must a Registered Gas Installer (RGI) complete the Domestic Gas Assessment (DGA) competency reassessment?
Legislation And Standards
Question · Easy
Which official documents define the performance criteria for the Irish Domestic Gas Assessment (DGA)?
Question · Medium
Is formal retraining mandatory before an experienced RGI may sit the five-year DGA reassessment?
Trades Exam Prep Podcast
Listen on Spotify
Podcast
How far in advance of the DGA expiry date may an RGI complete reassessment while retaining the full five-year validity period?
What happens if an RGI allows their Domestic Gas Assessment (DGA) certificate to expire without renewal?
Which accreditation standard must certification bodies use when certifying DGA assessors and the competency scheme?
Question · Hard
What must a candidate present to an accredited assessment centre before commencing the DGA reassessment?
After successfully completing the DGA, what must the RGI submit to RGII to update their registration record?
The DGA knowledge assessment is described in RGII criteria as which type of examination format?
How many practical competency areas are assessed in the Domestic Gas Safety Assessment (DGA) scheme?
Which Irish statute makes it an offence for an unregistered person to carry out designated domestic gas works?
Who appoints the Gas Safety Supervisory Body (GSSB) that operates the RGII register?
Which NSAI standard is the primary normative document for domestic natural gas and LPG installations assessed in the DGA?
An RGI replaces an existing domestic boiler on a property that already has a gas meter. Which Declaration of Conformance applies?
When must an RGI issue a Warning Notice (Unsafe Gas Installation notice) to a customer?
What is the emergency telephone number for Gas Networks Ireland gas escapes in the Republic of Ireland?
Which body approved the DGA assessment criteria developed by the RGII scheme committee?
An RGI certifies work they did not personally carry out or directly supervise. What is the regulatory consequence?
Which prior qualification satisfies the DGA prerequisite for an RGI who already holds domestic gas registration?
What information must appear on an RGI identity card regarding competency reassessment?
During DGA reassessment, an installer measures 45 ppm carbon monoxide in a room with a suspected appliance fault. What is the immediate action?
Combustion And Flues
What does a rising CO/CO2 ratio measured at a boiler flue sampling point most likely indicate?
A room-sealed boiler draws combustion air from where?
What is the primary purpose of a draught diverter on an open-flued gas appliance?
Yellow tipping on an otherwise blue natural gas burner flame usually indicates what condition?
For an open-flued appliance with 18 kW net heat input in a room, what permanent ventilation free area is required under I.S. 813?
Spillage testing on an open-flued appliance checks whether combustion products are entering the room. When should it be performed?
What is a balanced flue terminal?
Why must condensing boiler flues be installed with a fall back toward the boiler?
Complete combustion of methane (natural gas) in air produces which primary products?
An RGI finds a flue terminal blocked by a newly built garden structure. What is the correct classification before further work?
What minimum room volume applies to installing a flueless gas cooker in a kitchen under I.S. 813 guidance?
When checking a fanned-draught boiler, what must be verified before the burner is allowed to fire?
Liquefied Petroleum Gas (LPG) is heavier than air. Where will LPG collect if it leaks indoors?
What instrument is used to measure oxygen, CO, and CO2 in flue gases during appliance commissioning?
Permanent ventilation for a room containing only a room-sealed boiler typically requires what?
Flame lift on a burner is most commonly caused by what?
I.S. EN 1949 applies to which type of gas installation assessed in broader RGII domestic competency?
What is the main hazard of installing an oversized flue liner without proper design on a domestic gas appliance?
Before accepting a boiler commission as safe, which flue gas reading combination is most concerning?
What is the purpose of a let-by test on a newly installed domestic gas meter installation?
Pipework And Testing
At what pressure is a standard domestic let-by test typically performed?
For a domestic installation with a total gas volume not exceeding 0.02 m³, what tightness test pressure is typically applied?
When must a domestic gas installation be purged?
What is the maximum recommended pressure drop across a domestic gas meter at maximum flow?
Copper gas pipe passing through a masonry wall must be protected by what?
Which joint type is commonly used on domestic copper gas pipework installed to I.S. 813?
Loading more…