What does I.S. 10101:2020 represent in the Republic of Ireland?
Scope And Definitions
Question · Easy
Which organisation publishes Ireland's National Rules for Electrical Installations?
I.S. 10101:2020 replaced which previous edition of the Irish national wiring rules?
Trades Exam Prep Podcast
Listen on Spotify
Podcast
The voltage scope of I.S. 10101 covers electrical installations up to:
Question · Medium
Under I.S. 10101, the remit of the National Rules for Electrical Installations ends at:
In I.S. 10101:2020, what were formerly called "Parts" in ET 101:2008 are now labelled as:
Which body operates the Safe Electric scheme that ensures electrical contractors comply with I.S. 10101?
A "Registered Electrical Contractor" (REC) under the Safe Electric scheme is authorised to:
The nominal supply voltages commonly used for utilisation in Irish installations are:
General Characteristics
Chapter 3 of I.S. 10101 requires the designer to assess which of the following for every installation?
Which earthing system is commonly provided by ESB Networks to domestic and small commercial consumers in Ireland?
In a TN system, the protective measure relies primarily on:
When assessing external influences on an installation, which factor would require selection of equipment with a suitable IP rating?
Diversity factors are applied in design calculations to:
The harmonised conductor colour for the neutral in a new Irish installation is:
Prospective fault current at the origin of an installation is important to determine because it:
An installation designed for maintainability should allow:
Voltage drop in a lighting final circuit is generally limited to approximately what proportion of nominal supply voltage?
The two main categories of protection against electric shock in I.S. 10101 are:
Protection For Safety
Additional protection by a 30 mA RCD is required for general socket-outlet circuits because it:
Under I.S. 10101, socket-outlet circuits for general use must be protected by an RCD with a rated residual operating current not exceeding:
A notable change in I.S. 10101 compared with ET 101 is that 30 mA RCD protection is now also required for:
For a 230 V final circuit not exceeding 63 A in a TN system, the maximum disconnection time is:
For a 400 V final circuit not exceeding 63 A in a TN system, the maximum disconnection time is:
When testing a 30 mA RCD used for additional protection, at 5 times rated residual current (150 mA) it should trip within:
Question · Hard
I.S. 10101 states that Type AC RCDs in new installations are:
The main protective bonding conductor connects the main earthing terminal to:
Supplementary protective bonding in a bathroom may be required to connect:
Protection against thermal effects requires that conductors and connections are arranged to prevent:
Overcurrent protection is intended to protect against:
A circuit-breaker with a B-curve characteristic is typically suited to:
Discrimination (selectivity) between protective devices means that:
An RCD detects fault current by measuring:
Where cables are concealed in a wall at less than 50 mm depth and not in a permitted zone, additional protection is required such as:
Basic protection against direct contact may be achieved by:
Fault protection by automatic disconnection requires that:
A 300 mA RCD on a distribution circuit primarily provides:
In a TN-S system, the neutral and protective conductors are:
Arc fault detection devices (AFDDs) may be specified in I.S. 10101 to reduce risk from:
Surge protection devices (SPDs) under Clause 534 are selected to protect against:
Where an SPD risk assessment result is below the threshold specified in I.S. 10101, SPDs are:
Electrical separation as a protective measure is typically used for:
The touch voltage during an earth fault must be limited because:
When selecting cable size, the conductor cross-sectional area must be adequate for:
Selection And Erection
Grouping several cables together in a conduit or tray typically:
Under I.S. 10101 Clause 527, cables as a minimum should be rated at least:
Steel wire armoured (SWA) cable used underground typically requires: